M5 AS 1 000 Body size Lock nut option Nil J (3) 1 2 3 4 5 M3, M5 standard Hexagon lock nut Round lock nut 1 8 1 4 , standard standard standard standard 8 3 Note 3) Only for AS1000 2 1 Option H (1) 2 1 High temperature (5 to 80C) Thread type Low temperature (30 to 60C) L (2) Note 1) AS5000 is available as special. AS1000 is not applicable. Note 2) AS1000, AS2000 are not applicable.
S coupler #OILTUBE + + %NERGYSAVINGEFFECTSWITH "LOWGUN6-' 1 Amount saved as a result OFENERGYSAVINGEFFECTS #OSTOFELECTRICITYCONSUMEDBYCOMPRESSOR HUNDREDOF ) 20% reduction 1 306 /year 1 600 1 450 1 300 1235 Conventional model 1 150 "LOWGUN 3COUPLER #OILTUBE 1 000 HOURS 850 4OTALWORKINGHOURSOFUSE "LOWGUN6-' %NERGYSAVINGEFFECTSWITH only Calculation conditions Amount saved as a result
Applicable wafer size 200 mm 300 mm XM XY Non-cassette type DXSA Auto switch and connector XVD Symbol Auto switch Connector Nil A None Lead wire: 0.5 m (without connector) XGT XGT For 200 mm wafer For 300 mm wafer CYV With multiple connector Note 1) C Cassette type D-A93 (With 2 pcs. for opening and closing) (T3106 000: Made by AMP) With D-sub connector Note 2) F (CDE-9PF05: Made by HIROSE
x @ 0 1 N V : Capacity 2 0 : T ube I.D cm L : Tube length em V= 1000X4D2X L .Burst'prdof 0 x @ 0 Wat"'-o..wt(Wat..) 0 0 x @ 1 = 1 000 X"4 (O.6) 2X100 =O.02BR @ . llnte or no Influence o .
The MPa type displays up to 3 decimal places (.000).
For example, if the pressure is 0.120 MPa, it is displayed as “.120”. Note) Old ITV series regulators display only up to 2 decimal places (.00).
Body sizes: 16, 25, 32, 40; Stroke range: 50 to 1200mmin 50mm increments; Maximum work load: 75 kg (horizontal); 25 kg (vertical); Maximum speed: 1500 mm/s (H lead, size 25); Maximum acceleration: 10, 000 mm/s² (horizonal); 5,000mm/s² (vertical); Positioning repeatability: ±0.02mm (±0.015mm high precision type); Motor type: 24 VDC step motor with battery-less absolute encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s ²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with absolute batteryless encoder
I/O and actuator cables are also identical to the standard LEY Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s ²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Body sizes: 16, 25, 32, 40; Stroke range: 50 to 1200mmin 50mm increments; Maximum work load: 75 kg (horizontal); 25 kg (vertical); Maximum speed: 1500 mm/s (H lead, size 25); Maximum acceleration: 10, 000 mm/s² (horizonal); 5,000mm/s² (vertical); Positioning repeatability: ±0.02mm (±0.015mm high precision type); Motor type: 24 VDC step motor with battery-less absolute encoder
I/O and actuator cables are also identical to the standard LEY Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s ²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s ²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with absolute batteryless encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s ²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with absolute batteryless encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Type: Relay Device, Type: Electro-pneumatic lever type, Option: None, Pressure(MPa): N/A, Terminal box: N/A, Pilot valve: N/A, Fork lever type fitting: N/A, Lever unit: N/A, Compensation spring: N/A, External scale plate: N/A, Position feedback signal: N/A, Air connection port: Rc1/4, Conduit connection port: G1/2, Explosion-proof structure: Standard product, CE compatible: CE-non-compliant
Type: Relay Device, Type: Lever type, Connection Port Size: Rc1/4, Input pressure(MPa): 0.02 to 0.1 (standard), Pressure(MPa): N/A, Pilot valve: N/A, Fork lever type fitting: N/A, Lever unit: N/A, Position feedback signal: N/A, Ambient temperature(°C): -20 to 80 (standard)
"POSITIONER 1/4"" PT", IP, POSITIONER, 0.00000 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Type: Lever Type Feedback, Pressure Gauge: None, Construction: No Terminal Box, Accessories: ø0.7 Output Restriction w/Pilot Valve, Connection: -