The standard thread torques of the fittings are as shown in the below table. Proper tightening torque Nm 2.9 to 3.2 5.7 to 6.3 9.5 to 10.5 14.3 to 15.8 Connection thread size G1/8 G1/4 G3/8 G1/2 2. If using a fluororesin tube in an environment where the fluid temperature changes drastically, it is recommended to use an inner sleeve.

ID1 ID3 54 to 73 Same as ID1 ID4 74 to 93 Same as ID1 ID5 94 to 113 Same as ID1 Note) "0" is "no send" at mode of data writing. "1" and "2" contain "send" at mode of data writing. 42 - 12. 2 Controller IF status flagIN Data Controller IF flag is sent back to each ID ID=1 is shown below as an example [ID=1] I_Address bit 7 6 5 4 3 2 1 0 32 Abnormal station Connect station 33 Sending Sending

Keep wiring as short as possible to prevent interference from electromagnetic noise and surge voltage. Do not use a cable longer than 20 m. Wire the DC(-) line (blue) as close as possible to the power supply. -8No.PF-OMY0005-A Operating environment Do not use the product in an environment where the product is constantly exposed to water splashes.

Size Ejector System Vacuum Pump System Port Metric Inch Metric Inch PV 6 1/4 6 1/4 V 6, 8 1/4, 5/16 6, 8 1/4, 5/16 EXH (Port exhaust) 8 5/16 PE EXH Common Port open to atmosphere Note 1) PS 4 5/32 PD Note 2) M3 M3 : Not applicable Note 1) Piping for PE port is available as an option (M3). Refer to page 12. Note 2) A model with PD port (M3) is available as an potion. Refer to page 12.

type 1.8 [1.0] 41 to 95 [5 to 35] (400 V as standard) HRSH090 Inverter type 0.18 [0.1] 41 to 104 [5 to 40] Indoor use (400 V as standard) UL Standards (To be obtained) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.18 [0.1] 41 to 95 [5 to 35] (200 V only as an option) 4 Thermo-chiller Standard Type Series HRS100/150 Circulating Fluid Temperature Controller

1 AS-F !1 !2 TMH !2 !3 w ASD t y q i o e u t y q i o e u AS w AS-FE !0 KE !0 AS-FG AS-FG !9 AS-FP Meter-out type Meter-out type Meter-in type Meter-in type AS-FM Seal method: Face seal For G thread AS-D AS-T r !8 !4 !6 !7 !5 !1 ASP ASN !2 AQ w t y q i o e ASV AK !0 VCHC ASR ASQ u @0 Meter-out type Meter-in type Component Parts No.

It may vary substantially depending on an ambient environment.

As a result, the inside of the bowl q is shut off from the outside air. Therefore, even if there is an accumulation of condensate in the bowl q, it will not drain out.

W A momentary steep pressure increase due the spread of pressure by closing a contactor such as a valve for an extremely short time while there is a flow. This pressure increase is known as water hammer or impact pressure.

When the conduit type is used as equivalent to an Please be aware that there is a range of pressure that can be used. IP65 enclosure, install a wiring conduit, etc. 7. When an impact, such as water hammer, etc., caused by the rapid pressure fluctuation is applied, the solenoid valve may be damaged. Give an attention to it.

An over current error (Er1, Er2) is displayed. (1) Check that there is no noise interference such as static electricity, and check for noise sources.

When an impact, such as water hammer, etc., caused by the rapid pressure fluctuation is applied, the solenoid valve may be damaged. Give an attention to it. Warning 2.

Modules for use with external vacuum supply (from pump or mainline) or as an air driven ejector system. Safe Vacuum self-holding function by means of double solenoid valves.

Real-time switch output, accumulated switch output, or accumulated pulse output can be selected as an output type.

Do not use in an environment with temperature cycles. Consult SMC if switches are used where there are temperature cycles other than normal air temperature changes, as they may be adversely affected internally. 6. Do not use in an environment where there is excessive impact shock.

If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even for a short time, it may be adversely affected (damage, malfunction, or hardening of the lead wires). Do not use in an area where surges are generated.

The unit to connect input device such as an auto switch, pressure switch and flow switch, and the unit to connect output device such as a solenoid valve, relay and indicator light can be connected in any order.