The only possible way in that case is the use of an external stopper.

Connect the remote control cable and the switch to the connector for the contact input/output, supplied as an accessory. Then, mount the ferrite core (3 turn) supplied as an accessory. (See below) (This is an example of wiring. Refer to the Operation Manual for communication for details.)

Connect the remote control cable and the switch to the connector for the contact input/output, supplied as an accessory. Then, mount the ferrite core (3 turn) supplied as an accessory. (See below) (This is an example of wiring. Refer to the Operation Manual for communication for details.)

Vacuum switch Series ZS 13-1-6 Model Selection Single Unit System Equipment such as an ejector is configured as an individual unit. Thus, it is possible to create a flexible system configuration in which the circuit composition and the mounting locations can be selected as desired.

46 x n + 29 L2 = 46 x n + 14 10 489 474 9 443 428 8 397 382 7 351 336 6 305 290 5 259 244 4 213 198 3 167 152 2 121 106 L L1 L2 S070 With mounting adaptor: VV317-02-1-02-A VQ 4-7 mounting hole P = 46 VKF VQZ VZ Manual override (Non-locking) VS DIN terminal facing upward 141.6 VFN Applicable cable O.D. 6 to 12 L Dimension n: Stations Stations Formula L1 = 46 x n + 89 L2 = 46 x n + 59 2 181

Prepare an insert bushing and nut for 1/8" O.D. tubing (LQ-2U03) and change the tubing size. (Refer to the section on how to order fitting parts.) Note) Tubing is sold separately.

An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof.

With an ejector When a few air cylinders are locally used.

If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result, causing an accident.

The control signal of an entire system can be managed by Fieldbus System.

0 Vacuum pressure switch lead wire specifications Note 5) The filter included in this product is of an simple type, and will become clogged quickly in environments with high quantities of dust or particulates. Please make additional use of an air suction filter of the ZFA, ZFB or ZFC series.

The cushion effect (smooth start-up, soft stop) cannot be obtained in an intermediate stop or a return from an intermediate stop using an external stopper, etc.

In addition, by connecting an input block a maximum of 32 sensor signal inputs are possible. Input block This is an expansion block which connects to an SI unit to perform sensor input from auto switches, etc.

Performing such activity will likely cause an electrical shock. 2. Do not use this product in the presence of a magnetic field. Use in such an environment is likely to cause a malfunction. 3. Do not use this product in an atmosphere containing an inflammable gas, explosive gas, or corrosive gas. Use in such an atmosphere is likely to cause a fire, explosion, or corrosion.

Use an auxiliary pipe or the like and apply force evenly when tightening the cap screws on the cover and case.

If an accurate stopping position is required at the stroke end or midstroke, use an external stopper to secure accurate positioning.

An external pilot style that can be used individually is available as a made-to-order. For details, refer to the page 4-6-46.

Displayed if an internal data error has occurred. Turn the power off and on again.