Model Description AC10 AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60 G-27-10-R1 G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD27 G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD38 AD37 G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD38 AD37 G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD47 G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD47 G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD47 G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48
100 6-5-52 53 Series CG1Q Air Cylinder: Low Friction Type Double Acting, Single Rod With Mounting Bracket Without rod boot ZZ Axial Foot Style Axial foot style: CG1LQ Without rod boot Z Bore (mm) B LC LD LH LS LT LX LZ M W X Y 20 25 32 40 50 63 80 100 34 4 4 4 4 5 5 6 6 6 6 7 7 10 12 11 14 20 53 53 53 60 67 67 74 74 3 10 10 10 10 17.5 17.5 20 20 15 7 3 3 3 3 4.5 4.5 4.5 6 32 44 47 52 53
Facility water temperature 32C 12 Cooling capacity [kW] 10 8 Facility water temperature 40C 6 4 2 0 5 10 15 20 25 30 35 40 Circulating fluid temperature [C] Pump Capacity HRSH090--20/400.6 60 Circulating fluid pressure [MPa] 0.5 50 Outlet Pump head [m] 0.4 40 0.3 Usable flow rate range 30 0.2 20 Return port 0.1 10 0 0 20 10 40 30 50 60 70 Circulating fluid flow rate [L/min] 0 140 Thermo-chiller
M Weight (g) AS221F-U01-23 AS221F-U01-04 AS221F-U01-06 AS221F-U01-08 AS221F-U01-10 AS221F-U02-04 AS221F-U02-06 AS221F-U02-08 AS221F-U02-10 AS321F-U02-06 AS321F-U02-08 AS321F-U02-10 AS321F-U02-12 AS321F-U03-06 AS321F-U03-08 AS321F-U03-10 AS321F-U03-12 AS421F-U04-10 AS421F-U04-12 Model Applicable tubing O.D. d 3.2 4 6 8 10 4 6 8 10 6 8 10 12 6 8 10 12 10 12 27.9 28.2 29.6 32.4 40.2 32.5 33.1
M1 3A = M1E/M1E max = 2.25/10 = 0.225 m x g L1 M1E FE M3E = 0.05 x a x m x L2 (FE = 1.4/100 x a x g x m) = 0.05 x 300 x 3 x 0.04 = 1.8 [Nm] Investigate M3E. a From above, find the value of M3E max at 420 mm/s in Graph (3).
An error code is returned if an instruction code outside the range set in parameter No.
9.4 Cooling capacity 9-7 HRX-OM-W038 Chapter 9 Documents 9.6 Pump capacity 9.6.1 HRS040--20-(BJMWZ) 0.3 0.3 30 Availavel area (Min. neccesary flow5L/min) Circulating fluid pressure[MPa] Availavel area (Min. neccesary flow5L/min) Circulating fluid pressure[MPa] 20 Outlet60Hz 0.2 20 Outlet60Hz 0.2 Pump head[m] 20 Pump head[m] 10 0.1 10 Outlet50Hz 0.1 10 Outlet50Hz Return port Return port 0.0
Note 1) Only type E (Reed switch) is applicable as an auto switch when mounting a housing of 10.
Clamp stroke Manufacturable Range of Body Options Clamp stroke 10 mm 20 mm 50 mm Applicable bore (mm) 12 to 40 12 to 63 50 to 63 Symbol 10 20 50 Bore size (mm) 12, 16 20 to 63 FN MF N F M Nil Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
TdH9 TB +0.036 0 +0.036 0 +0.043 0 CLG-020-24 CLG-025-24 CLG-032-24 CLG-040-24 20 25 32 40 42 48 53 60 10 10 10 10 5.5 5.5 6.6 6.6 31 37 38.5 42.5 40 47 47 55 20 25 32 40 36 43 50 58 10 10 10 10 5.5 5.5 6.6 6.6 25 30 35 40 (29.3) (33.1) (40.4) (49.2) 8 10 12 14 8 10 12 +0.043 0 14 CG-020-24A CG-025-24A CG-032-24A CG-040-24A Applicable bore size (mm) Applicable bore size (mm) Part no.
Reduced apparent power 10 VA m 7 VA (Size 1) Normally Closed (N.C.)
Note 4) Combinations of M and H, H and M, R and S, S and T, L and M are not available.
TdH9 TB +0.036 0 +0.036 0 +0.043 0 CLG-020-24 CLG-025-24 CLG-032-24 CLG-040-24 20 25 32 40 42 48 53 60 10 10 10 10 5.5 5.5 6.6 6.6 31 37 38.5 42.5 40 47 47 55 20 25 32 40 36 43 50 58 10 10 10 10 5.5 5.5 6.6 6.6 25 30 35 40 (29.3) (33.1) (40.4) (49.2) 8 10 12 14 8 10 12 +0.043 0 14 CG-020-24A CG-025-24A CG-032-24A CG-040-24A Applicable bore size (mm) Applicable bore size (mm) Part no.
(Supply pressure 0.3 MPa) External air inlet Compressed air External air inlet Yes None Reduced by 50% Air consumption flow rate L/min (ANR) 10 10 Ionized air Discharge time sec 2.5 2.5 5 Compressed air Improved 6 times Ionized air flow velocity m/s 0.4 At 300 mm distance External air inlet External air Neutralizing static electricity from an electric substrate Neutralizing static electricity
The switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 2. Mount the switch in a locations where there is no vibration greater than 98 m/s2 or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.
steel 304) Nominal filtration accuracy (m) 5 10 20 40 74 105 Symbol 005 010 020 040 074 105 (Size 65 x L250) 42
160C (40 to 71C) (No freezing) 1) 0.07 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 2) 4 x 10-9 Pam3/sec 2) Ra max 10 in. (0.25 m) Option: 7 in. (0.18 m), 5 in. (0.13 m) Face seal, Tube weld 0.20 psig (0.0014 MPa) rise in delivery pressure per 20 psig (0.14 MPa) source pressure drop Bottom mount 0.19 in3 (3.1 cm3) 0.99 lbs (0.45 kg) 3) Delivery pressure Gas Source pressure Proof pressure (Inlet)
12 9.5 10 9.5 13.5 11 13 10 10.5 9.5 14.5 12.5 14 11 9.5 10 14.5 13 14 11 9.5 11 15.5 14.5 15 12 8 12 9.5 11 10 8.5 13 10.5 12 9.5 10 9.5 13.5 11 13 10 10.5 9.5 14.5 12.5 14 11 9.5 10 14.5 13 14 11 9.5 11 15.5 14.5 15 12 CHM CHS CH2 CH2 CHA CH2F (mm) Auto switch model Bore size (mm) 32 Related Products 40 50 63 80 100 D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59/F59F D-F5W/J59W D-F5BA
Note Conductor resistance W/km, 20C 65 or less 1.5 m AXT100-DS25-015 Cable 0.3 mm2 Approx. 10 x 25 cores 3 m AXT100-DS25-030 5 m AXT100-DS25-050 Voltage limit VAC, 1 min. 1000 L * For other commercial connectors, use a 25pin type female connector conforming to MIL-C-24308. * Cannot be used for transfer wiring.