Note 3) Not offered in 7/8", 1 1/4", or 2" or with rod boot. Note 4) Double acting only. Note 5) Not available as standard with C, R mount, with rod boot. Note 6) See specifications for standard and maximum stroke lengths. Note 7) Rubber cushions are offered at no additional cost on 7/8" and 1 1/4". They are options on the other bore sizes.
13 7 6 9 8 11 10 3 Connector B terminal no.
13 7 8 9 10 11 ON OFF H P-OT 0 1 2 3 4 5 6 Forward Run Prohibited Pn50A.3 7 8 L /P-OT 9 A B C D E F H N-OT 0 1 2 3 4 5 6 Reverse Run Prohibited Pn50B.0 7 8 L /N-OT 0 A B C D E F L /P-CL 0 1 2 3 4 5 6 Forward External Torque Limit Pn50B.2 8 7 H P-CL 9 A B C D E F L /N-CL 0 1 2 3 4 5 6 Reserve External Torque Limit Pn50B.3 8 7 H N-CL 9 A B C D E F L /DEC 0 1 2 3 4 5 6 Homing Deceleration LS
Green 3 COM-A/COM B-3 A 10mNote) Blue 4 COM-B/ A-3 B 15mNote) (c) Shield Cable colour Terminal number C 20mNote) Vcc B-4 Brown 12 Black 13 GND A-4 A B-5 Red 7 Note)Produced upon Black 6 A A-5 receipt of order B B-6 Orange 9 Black 8 B A-6 (Only "Robotic type cable" 3 is available) Actuator side Controller side (14.2) (b) 2 1 (5.5) (14) (a) B A1 5 6 (17.7) 1 (c) 2 1 A6 B6 (18) (6.3) 16 15
T) View Z (mm) Dimensions A B C D M N T U V Model LVQ20-S-2 LVQ30-S-2 LVQ40-S-2 LVQ50-S-2 LVQ60-S-2 25.5 46 31.5 58 7 15 35.3 10.6 7 23.5 47 29.5 59 7 15 36.9 16.5 10 23.5 47 29.5 59 7 20 37.9 22 35 70 41 82 7 20 64 25 17 35 70 41 82 7 20 66 32 17-5-69 8 Series LVQ Dimensions With flow rate adjustment & by-pass High back pressure spec. with flow rate adjustment & by-pass N.C. valve M N
38 4 5 127 41 M8 x 1.25 19.5 25 182 25 30 24 15 27 5.5 41 33.5 195 7 8 M26 x 1.5 41 9 7 6 137 45 M10 x 1.25 24 32 184 32 34.5 24 15 27 5.5 41 37.5 8 197 7 M26 x 1.5 41 9 7 6 139 45 M10 x 1.25 24 40 217 40 42.5 24 21.5 29 7 45 46.5 233 10 8 11 M32 x 2 41 7 8 167 50 M14 x 1.5 24 9-2-24 23 Series CLM2 Fine Lock Cylinder Double Acting, Single Rod Single Clevis Style (C) Rc BQ locking port for
Therefore, if the target temp. is 23.0 C and 1.5 C is set in this item, the warning [WRN] arises when temp. lowers 21.5 C. 8. High Temp. Cutoff H i g h T e m p . Setting range : 11.0 to 70.0 C Min. increment : 0.1 C Indicated content : High temp. cutoff by internal temp. C u t o f f M O D E < 7 0 . 0 C sensor (Ex. : 70.0 C).
C B A 4 x H through (Hole for mounting attachment) S S O O B A (mm) (mm) Model A 2.5 3 4 5 6 7 9 Model A 2.5 3 4 5 6 7 9 B 5 5.7 7 9 12 14 17 B 5 5.7 7 9 12 14 17 C 2 2 2.5 4 5 6 7 H 2.4 2.9 3.4 4.5 5.5 6.6 9 MM M2 x 0.4 M2.5 x 0.45 M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 MHZ2-62 MHZ2-10 MHZ2-6 1 MHZ2-10 2 N2 2 N2 2 N2 2 N2 1 N1 1 N1 1 N1 MHZ2-16 MHZ2-16 MHZ2-20 MHZ2-20 MHZ2-25
SCY1L, #1 (#1 + #7) CY1L10 . SCY1L, #2 (#2 + #7) CY1L15 . SCY1L, #3 (#3 + #7) CY1L25 . SCY1L, #4 (#4 + #7) CY1L32 . SCY1L, #5 (#5 + #7) CY1L40 .
9 10 10 10 ZP20U ZPT3-7A-X2 ZP 25 U ZPG25U-7A-X2 10 10 10 11 ZP25U ZP 32 U ZPG32U-7A-X2 10 11 11 12 ZP32U ZP 10 C ZPG10C-7A-X2 7 7 7 7 ZP10C ZPT2-7A-X2 ZP 13 C ZPG13C-7A-X2 7 7 7 7 ZP13C ZP 16 C ZPG16C-7A-X2 7 7 7 8 ZP16C ZP 20 C ZPG20C-7A-X2 9 10 10 11 ZP20C ZPT3-7A-X2 ZP 25 C ZPG25C-7A-X2 10 10 10 11 ZP25C ZP 32 C ZPG32C-7A-X2 10 11 11 12 ZP32C ZP 10 B ZPG10B-7A-X2 7 7 7 8 ZP10B
+ Stroke B + Stroke A + Stroke WA Z JB 6H7 depth 10 FA FB S K E G 6H7 depth 10 With front lock 7 6 HN 10 5 6H7 DM 23 b a Section XX detail e c d End lock mechanism (Locking type manual release) T-slot dimensions (mm) 30 Bore size (mm) a b c d e With rear lock 13.3 20.3 12 8 22.5 80 15.3 23.3 13.5 10 30 100 (mm) Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB GC H HA J JA JB K L 80
from DIO REMOTE to LOCAL. . 5-13 5.4.3 Example 3: Alarm signal of contact signal is changed from N/A to ALARM1. . 5-14 Chapter 6 Error Message and Troubleshooting . 6-1 6.1 Error Message . 6-1 6.2 Troubleshooting . 6-2 Chapter 7 System Maintenance . 7-1 7.1 Water Quality Management . 7-1 7.2 Inspection and Cleaning . 7-2 7.2.1 Daily inspection . 7-2 7.2.2 Quarterly inspection . 7-3 7.3 Storage
C U U O O S S L L H H 8 3 11.5 5 L2 dimension Stations 1 2 3 4 5 6 7 8 9 M DIN rail part no.
C U U O O S S L L H H 8 3 11.5 5 L2 dimension Stations 1 2 3 4 5 6 7 8 9 M DIN rail part no.
13 7 8 9 10 11 ON OFF H P-OT 0 1 2 3 4 5 6 Forward Run Prohibited Pn50A.3 7 8 L /P-OT 9 A B C D E F H N-OT 0 1 2 3 4 5 6 Reverse Run Prohibited Pn50B.0 7 8 L /N-OT 0 A B C D E F L /P-CL 0 1 2 3 4 5 6 Forward External Torque Limit Pn50B.2 8 7 H P-CL 9 A B C D E F L /N-CL 0 1 2 3 4 5 6 Reserve External Torque Limit Pn50B.3 8 7 H N-CL 9 A B C D E F L /DEC 0 1 2 3 4 5 6 Homing Deceleration LS
(Example) 40: D-A3;C-4, 50: D-A3;C-5, 63: D-A3;C-6, 80: D-A3;C-8, 100: D-A3;C-10 BA4-040 BA4-040 BA4-063 BA4-080 BA4-080 [Stainless Steel Mounting Screw] The following stainless steel mounting screw kit (including set screws) is also available. Use it in accordance with the operating environment. (Since the auto switch mounting bracket is not included, order it separately.)
66 5 2 1/4, 3/8 103 18 98 90 5 90 10 150 80 28 8 7 7 14 7 12 50 95 34 80 5 2.3 3/8, 1/2 132 57 Odor Removal Filter Series AMF Dimensions AMF450C/550C P D Q T R E D N F L U Bracket (Accessory) O J K M V W B IN OUT C I A G Maintenance space H (mm) A Model Port size Bracket related dimensions B C D E F G H I 172 N 90 J 31 K 10 U 9 V 9 L 18 M 9 W 15 O 55 P 111 Q 50 R 88 T 3.2 AMF450C AMF550C
HRLE050-W-20 HRLE050-W-20 [50 Hz] [60 Hz] 7 7 Facility water temperature 25C Facility water temperature 32C 6 6 Cooling capacity [kW] Cooling capacity [kW] Facility water temperature 25C 5 5 4 4 Facility water temperature 32C 3 3 Facility water temperature 40C Facility water temperature 40C 2 2 1 1 0 0 15 20 25 Circulating fluid temperature [C] 15 20 25 Circulating fluid temperature [C] *
USB 7. 106 No.SFOD-OMT0009CN-B 7. 7. 4. ( EMG ) 4. 107 No.SFOD-OMT0009CN-B 1. 1.1 LEY/LEYG LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 A B C A B C A B C A B C [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 [mm] 300 300 300 400 400 400 500 500 500 500 500 500 [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 [mm/s] 15 8 4 18 9 5 24 12 6 24 12 6 () [mm/s] 22 12 6 26 13 7 34 17 9 34