The signal has to be converted by a A/D converter for pressure display or switch output. Current Output signal is a current signal in the range of 4 to 20[mA]. The signal is transformed into a voltage signal before being converted by a A/D converter for pressure display or switch output.
Accessory (Option) Basic size (Applicable compressor kW) F With screw flange D With auto-drain Port size Symbol 2 Screw type Reciprocating type 2.2 7.5 15 22 37 55 75 04 06 14 20 30 Rc 1 2 Rc 3 4 Rc 1 1 2 Rc 2 3B flange HAW2 HAW7 HAW22/37 HAW55/75 HAW110 Caution on Design 7 22 22 Warning 1.
No.CE*-OMP0002-A 3 CEU1 SMC FG 0~50 35~85%RH 3 CEU1CE10.1mm 3 CE1-R** CE1** 3 CEU1** FG 3 DIN 3 2m/s 3 (100ms) 2 2 2 2-1 1 1 1 CEU1 4 2 2 2 2-2 2 2 2 3 3 3 3-1 1 1 1 : : 1 1 (mm) (mm) 25 25 25 25 50 50 50 50 75 75 75 75 100 100 100 100 125 125 125 125 150 150 150 150 175 175 175 175 200 200 200 200 250 250 250 250 300 300 300 300 400 400 400 400 500 500 500 500 12 12 12 12
A A B C D E F A B C D A B C D A B C D A B C D Tubing O.D. PA 1 2 1 2 3 4 1 2 3 4 5 6 1 2 3 4 1 2 3 4 1 2 3 4 1/8" 1/8" PAX 1/8" 1/8" PB 1/4" 1/4" 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 1" 1" Note) For each body class, the second and later numbers or symbols indicate reducing.
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating
Magnet: D (Built-in), Mounting: U (Front Trunnion), Style: N (Non-lube Rubber Bumper), Bore Size: 40mm, Thread: None, Stroke: 100mm, Option: None, Lock Style: E (Spring Lock (Exhaust Lock))
Magnet: D (Built-in), Mounting: U (Front Trunnion), Style: N (Non-lube Rubber Bumper), Bore Size: 40mm, Thread: None, Stroke: 150mm, Option: None, Lock Style: P (Air Pressure Lock-up (Pressure Lock))
Magnet: D (Built-in), Mounting: U (Front Trunnion), Style: N (Non-lube Rubber Bumper), Bore Size: 40mm, Thread: None, Stroke: 300mm, Option: None, Lock Style: E (Spring Lock (Exhaust Lock))
Magnet: D (Built-in), Mounting: U (Front Trunnion), Style: N (Non-lube Rubber Bumper), Bore Size: 40mm, Thread: None, Stroke: 25mm, Option: None, Lock Style: E (Spring Lock (Exhaust Lock))
Magnet: D (Built-in), Mounting: U (Front Trunnion), Style: N (Non-lube Rubber Bumper), Bore Size: 40mm, Thread: None, Stroke: 150mm, Option: None, Lock Style: E (Spring Lock (Exhaust Lock))
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating
Magnet: Built-in, Mounting: Front Trunnion, Style: Non-lube Rubber Bumper, Bore Size: 40mm, Thread: None, Stroke: 100mm, Option: None, Lock Style: Spring Lock (Exhaust Lock), Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Trunnion, Style: Non-lube Rubber Bumper, Bore Size: 40mm, Thread: None, Stroke: 150mm, Option: None, Lock Style: Air Pressure Lock-up (Pressure Lock), Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Trunnion, Style: Non-lube Rubber Bumper, Bore Size: 40mm, Thread: None, Stroke: 300mm, Option: None, Lock Style: Spring Lock (Exhaust Lock), Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Trunnion, Style: Non-lube Rubber Bumper, Bore Size: 40mm, Thread: None, Stroke: 150mm, Option: None, Lock Style: Spring Lock (Exhaust Lock), Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
JOG operation positioning operation programmed operation DO forced (Note 4) 0 0. b output single-step feed (Note 4) Test operation mode # #. d (Note 1) Motor-less operation # #.
JOG operation positioning operation programmed operation DO forced (Note 4) 0 0. b output single-step feed (Note 4) Test operation mode # #. d (Note 1) Motor-less operation # #.
SY3000 manifold model Ejector valve number SX3000-75-1A SY3140-5LZ SY3240-5LZ ZYY35LZ-10S-E15C 1 SET 1 SET 1 SET 1 SET is the symbol for a built-in assembly. Add the symbol at the beginning of part numbers for solenoid valves, etc. to be mounted, and enter these together in order from the D side.
Double acting, Single rod Double acting, Double rod CE1 50 63 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 CE2 80 100 ML2B C J G5-S CHQB CHQWB CV MVGQ CC For details, refer to the catalog CAT. E111.
Press the "UP"and "DOWN"buttons to change the set value. d. Press the "SET"button. d. Press the "SET"button. The set value will light up. The set value will light up. * When the set value is flashing, it is not registered. * When the set value is flashing, it is not registered.