(Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: A93
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
(Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: A93
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion
Stroke(mm): 60, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: Rubber bumper (Standard), Auto Switches: A93
If using other screws, switch may be damaged. 12-13-16 17 Solid State Switch Direct Mounting Style D-Y59 /D-Y69 /D-Y7P(V) A B A B For details about certified products conforming to international standards, visit us at www.smcworld.com.
If using other screws, switch may be damaged. 12-13-16 17 Solid State Switch Direct Mounting Style D-Y59 /D-Y69 /D-Y7P(V) A B A B For details about certified products conforming to international standards, visit us at www.smcworld.com.
Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size
A B A 22 22 U U (24.5) ( ): For D-A93 type D-H7 D-H7W D-H7NF D-H7BAL D-C7 D-C8 RSQ RSG RS MI U U B A 26 B A 29 D-C73C D-C80C D-H7C U U B A 36.7 B A 38.2 Auto Switch Proper Mounting Position Auto Switch Mounting Height Auto switch model (mm) (mm) Auto switch model D-C7 D-C80 D-H7 D-H7W D-H7NF D-H7BAL D-C7 D-C80 D-C73C D-C80C D-H7BAL D-H7W D-H7 D-H7C D-A9 D-M9 D-M9W D-A9 D-M9 D-M9W D-H7C
LD Piping port P Operating direction A 7 Piping port P Operating direction B W K G With switch rail Q + Stroke Z + Stroke Piping port P (plug) Operating direction B HS CR HR Plug 22 8 Piping port P Operating direction B Piping port P (plug) Operating direction B 8 Piping port P Operating direction A 16 19.5 16 Plug REBR15 REBR15 (mm) A B C CB CR D F G GP GW H HA HB HC HP HR HS HT Model REBR15
AS600 (258) AS420 (102) AS600 (258) AS600 (258) AS600 (258) AS800 (586) AS500 (123) 1-A 2-B 1-C 2-A 2-B 1-A 2-B 2-A 2-B 2-B 2-B 2-B 2-B 1-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B 2-A 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 20 8, 10 1/4 500 9.5 0 1,000 2,000 3,000 Maximum speed Vmax (mm/s) 50 12, 16 1/4, 3/8 1000 19 63 Composed effective area So (mm2) Composed effective area So (mm2)
(Detection at stroke end) and Its Mounting Height [mm] Auto Switch Proper Mounting Position (Standard type) Auto switch model D-Y59l D-Y69l D-Y7P D-Y7PV D-Y7H D-Y7lW D-Y7lWV D-Z7l D-Z8l D-M9l D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV D-F5l D-J59 D-F59F D-F5NT D-A5l D-A6l D-A59W D-G39 D-K39 D-A3l D-A44 D-A9l D-A9lV D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B 32 10 8 6 4 6.5
38 35 42 40.5 A 33 32.5 34 31 38 36.5 49.5 48.5 A B A B A B A B 20 25 32 40 50 63 80 100 B 24 (32) 24.5 (32.5) 25 (33) 27 (36) 32 (44) 33.5 (45.5) B 14.5 (22.5) 15 (23) 15.5 (23.5) 17.5 (26.5) 22.5 (34.5) 24 (36) 29 (43) 30 (44) B 20 (28) 20.5 (28.5) 21 (29) 23 (32) 28 (40) 29.5 (41.5) B 16 (24) 16.5 (24.5) 17 (25) 19 (28) 24 (36) 25.5 (37.5) 30.5 (44.5) 31.5 (45.5) Hs 27.5 30 33.5
MGC MGF CY1 q B MY1 Normally ON w * Adjust the switch position according to load and speed.
7 2 38 12 6.6 11 12 A B 34 16 34 16 H Cross section AA Cross section BB (NN-1) X H G (mm) Note) Refer to "Dimensions" of MXS25 on P. 64 for one with shock absorber as symmetric.
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.
Rotational axis B d D I m kgm I = m kgm 8 8 Gear: I a + b I = m kgm IB = I + I + I kgm 12 Substitute the moment of inertia IB for rotation around shaft B with the moment of inertia IA for rotation around shaft A. Gear: I IA = (A/B)IB [A/B: Gear tooth ratio] Find the actual moment of inertia.
U B A CHA B A Related Products D-F7 D-F7W D-J79 D-J79W D-A7 D-A7H D-A8 D-A8H D-F7V D-F7WV D-F7BA D-F7BAV D-F7NT D-F79F D-J79C D-A73C D-A80C 32 to 100 DApprox. U B A Approx.