SMC Corporation of America
Elite Part Number Search
Search Results "CDBG1LN63-600-HL-M9BZ-C"

C D 15 (mm) Auto switch model A D-F9 B C D D-A9 D-F9 D-A9 D-F9 D-A9 D-F9 Bore size (mm) 17.5 15 D-A9 21.5 76.5 72.5 56.5 60.5 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 (mm) A D-Y5 D-Y7 D-Y7W B C D Auto switch model D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 101 103 47 47 78 78 22 32 30.5

Indication Item Setting and selection Setting range [High] Set the temperature range of the circulating fluid SP. +0.1 C to +10.0 C +1.0 C Upper/lower temperature limit (1) High/ Low [Low] Set the temperature range of the circulating fluid SP. -0.1 C to -10.0 C -1.0 C TEMP READY signal is output when the set time has passed after the circulating fluid temperature rises/drops within the

HOW TO O R D E R X T A1 NC A U T O S W I T C H C O N S T R U C T I O N T Y P E (PLEASE SEE PAGE 1 FOR CONSTRUCTION DETAILS) Standard D Auto Switch capable (Stainless and Steel Construction (1.5~14) All Stainless Steel (1.5~14) Steel w/ Composite Tube (1.5 14) Stainless Steel w/ Composite Tube (1.514) ST SS SCT SSCT ...

150 300 450 600 750 900 1050 1200 1350 Distance [mm] Distance [mm] 5) Supply pressure: 0.4 MPa Flow rate consumption: 316 L/min (ANR) 6) Supply pressure: 0.5 MPa Flow rate consumption: 390 L/min (ANR) 200 200 2 s 150 150 1.5 s 100 100 50 50 0.5 s 1 s 1.5 s 0.5 s 1 s 50 50 100 100 150 150 200 200 1500 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900 1050 1200 1350 Distance

AMD AMH Data A: Inlet Air Temperature Data B: Ambient Temperature Data C: Inlet Air Pressure AME Inlet air temperature Ambient temperature Inlet air pressure MPa psi Correction factor F C Correction factor AMF Correction factor IDFB3E to 37E IDFB55E, 75E 1.31 F C 77 90 95 100 104 25 32 35 37.8 40 75 100 110 120 125 150 175 200 232 0.53 0.70 0.76 0.83 0.86 1.03 1.21 1.38 1.60 1.24 0.95 ZFC

Indication Item Setting and selection Setting range [High] Set the temperature range of the circulating fluid SP. +0.1 C to +10.0 C +1.0 C Upper/lower temperature limit (1) High/ Low [Low] Set the temperature range of the circulating fluid SP. -0.1 C to -10.0 C -1.0 C TEMP READY signal is output when the set time has passed after the circulating fluid temperature rises/drops within the

Indication Item Setting and selection Setting range [High] Set the temperature range of the circulating fluid SP. +0.1 C to +10.0 C +1.0 C Upper/lower temperature limit (1) High/ Low [Low] Set the temperature range of the circulating fluid SP. -0.1 C to -10.0 C -1.0 C TEMP READY signal is output when the set time has passed after the circulating fluid temperature rises/drops within the

600 600 600 Y 400 400 400 400 Mer m 200 200 200 200 0 0 0 0 0 10 20 30 40 50 0 10 20 30 40 50 60 0 2 4 6 8 10 12 14 16 0 4 8 12 16 20 24 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 2000 2000 2000 2000 Mep 1500 1500 1500 1500 L3 [mm] L3 [mm] L3 [mm] L3 [mm] m 1000 1000 1000 1000 L3 Z 500 500 500 500 0 0 0 0 0 10 20 30 40 50 0 2 4 6 8 10 12 14 16 0 4 8 12 16 20 24 0 10 20 30

A A a B B s j C f g t C0.5 C0.2 C0.2 b d e 45 45 Section A-A p k C0.5 45 C n h i l (d) C0.5 q m O Section B-B r (l) View C (mm) +0.2 0 l i o j k m n p q r s t b e g a c d f h Model 0 0.2 0.05 0.15 + 0.1 0 +0.2 0 3.5 +0.013 +0.001 CXS 6 2.75 M2.5 x 0.45 4.5 3.5 4.75 C0.5 2.8 0.5 4 3.5 3 3.5 16 0.1 M3 x 0.5 4 1 5.5 6 +0.2 0 0.05 0.15 0 0.2 + 0.1 0 +0.2 0 5 +0.016 +0.001 CXS10 4 M3 x 0.5 8 5

Built-in magnet for auto-switches CE1 CE2 Maximum Driving Speed of Cylinders ML2B 1000 1000 900 900 C J G5-S Load factor: 10% Load factor: 50% 800 800 Cylinder speed (mm/s) Cylinder speed (mm/s) 700 700 600 600 CV 500 500 400 400 MVGQ 300 300 200 200 CC 100 100 0 0 12 16 20 25 32 40 50 63 80 100 RB SYJ3000 VZ3000 VZ5000 VF3000 Bore size (mm) J Series Variations DDetailed specifications

N.O. 2 B A 2-position double (Rubber) 4-position dual 3-port valve (C) VQC 1/2 VQC 1/2 2(B) 4(A) 2(B) (A)4 Note) C VQC 4/5 (R1)5 1 (P) 3(R2) C Turn locking type (Manual) 1(P) 5(R1) 3(R2) N.C. N.O.

7 Type C snap ring for hole Carbon tool steel Aluminum alloy !8 !

Thread type Rc Nil Control equipment Symbol A Nil AP M MP F G C E NPTF T G F Air filter with auto-drain Air filter with manual drain Regulator Air release valve Pressure switch Blanking plate (Air release valve) Note) It is not applicable to O n e t o u c h fittings.

2 D Voltage output (0 to 10 V)*1*3 0 V 0.1 V 10 V Model Minimum value of rated flow range*4 Maximum value of rated flow range PF3A703H 30 L/min 3000 L/min PF3A706H 60 L/min 6000 L/min PF3A712H 120 L/min 12000 L/min A C 0 0 *1 Analog output accuracy is within 3% F.S. *2 A and C will change according to the setting of the zero cut function. *3 The analog output current from the connected

Min. load impedance: 50 Max. applied voltage: 28 V, Max. load current: 80 mA, Internal voltage drop: 1 V or less C: Analog output: 1 to 5 V Output impedance: 1 k D: Analog output: 4 to 20 mA Max. load impedance: 600 Min. load impedance: 50 PNP (1 output) + External input type PFMC7--HNPN (1 output) + External input type PFMC7--GBrown DC (+) Brown DC (+) Load U Black OUT1 Black OUT1 Main

Temperature characteristics 0 to 50C (With no condensation) Operating temperature range IP65 equivalent Enclosure Connection type Built-in One-touch fittings z, x, c: 4 Metric size For single unit z, x, c: 5/32" Inch size Connection size z, c: 6, x: 4 Metric size Manifold z, c: 1/4", x: 5/32" Inch size (1) Weight 100 g or less (without options) Note 1) Indicates the weight of a single unit

Positioning Mode: Minimum actuator travel distance of 1[m]. 28 - Recommended Parameter Values [LEY] LEY25/LEYG25 LEY25D/LEYG25D LEY32/LEYG32 LEY32D/LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Parameter *1,*2 Para. No Initial value Recommended value Number of command input pulses per revolution *3. PA05 100 100 Electronic gear numerator *3.

Monitoring start timer -06 0 to 600 minutes Range over detection timer 5 5 to 999 seconds AL05 High circulating return temp.

C J G5-S Auto Switch Mounting Bracket Part No.

IDX-OM-W093-B / Series IDF60-20-A,C,L,R,T,V IDF60-30-A,C,L,R,T,V IDF70-20-A,C,L,R,T,V IDF70-30-A,C,L,R,T,V IDF80-20-A,C,L,R,T,V IDF80-30-A,C,L,R,T,V IDF90-20-A,C,L,R,T,V IDF90-30-A,C,L,R,T,V URLhttp://www.smcworld.com/ English instruction manual can be downloaded from our URLhttp://www.smcworld.com/ SMC *1) JIS B8370 *2) ISO4414 *1) ISO4414Pneumatic fluid power Recommendations for the application