Body Size: 4000, Thread: N (NPT), Port Size: 04 (1/2), Option: B (w/Bracket), Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Body Size: 4000, Thread: N (NPT), Port Size: 04 (1/2), Option: BS (w/Bracket, Silencer), Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Body Size: 4000, Thread: NPT, Port Size: 1/2, Option: w/Bracket, Voltage: 24 VDC, Lead Wire: Type D, DIN Terminal w/Connector, Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units
Body Size: 4000, Thread: NPT, Port Size: 1/2, Option: w/Bracket, Silencer, Voltage: 24 VDC, Lead Wire: Type D, DIN Terminal w/Connector, Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units
Body Size: 2000, Thread: NPT, Port Size: 1/4, Option: None, Voltage: 24 VDC, Lead Wire: Type D, DIN Terminal w/Connector, Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units
Body Size: 5000, Thread: NPT, Port Size: 3/4, Option: None, Voltage: 24 VDC, Lead Wire: Type D, DIN Terminal w/Connector, Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units
Body Size: 2000, Port Thread: NPT, Port Size: 1/4, Option: None, Voltage: 24 VDC, Electrical Entry: Type D, DIN Terminal w/Connector, Surge Suppressor: None or Manual Override, Flow Direction, Pressure Unit: Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units
Regulator Unit Combination: [Other FRL Combination Devices] Soft Start Up Valve, Port Size: NPT1/2, Filter Rating: 5μm, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Reverse Flow (Right to Left)] Right to left, Drain Cock: [Not Provided] No, Pressure Gauge
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. OSHA compliant, lockable soft start valve, Large effective area, Low power consumption, Modular design, SOFT START-UP VALVE, VALVE, SOFT START LOCKOUT, 243, 0.68000 lb
O-ring Body Seal Stud Can be used for a wide range of pressures from a low vacuum up to a pressure of 1 MPa. Effective when piping in a confined space. Body part rotates allowing for positioning. The use of a special profile ensures sealing and reduces resistance when the tube is inserted.
-02-04(S)A 4 8.2 AS22l1FG-02-06(S)A 6 10.4 23.4 32.7 (32.8) AS22l1FG-02-08(S)A 8 13.2 23.9 33.2 (33.3) 14.2 18 (19) AS22l1FG-02-10(S)A 10 15.9 26.9 36.2 (36.3) 15.6 19 (20) AS32l1FG-02-06(S)A 6 1/4 17 (17.5) 13 13.3 40 (40) AS32l1FG-02-08(S)A 8 13.2 22.7 33 14.2 41 (41) AS32l1FG-02-10(S)A 10 15.9 26.7 37 35.7 15.6 42 (42) AS32l1FG-02-12(S)A 12 18.5 29.7 40 34.5 17 43 (43) AS32l1FG-03-06(S
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
A ridge shape has been created as a Uni thread for common applications for Rc, G, NPT and NPTF. AS-FM Note) Universal type is not available.
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. OSHA compliant, lockable soft start valve, Large effective area, Low power consumption, Modular design, SOFT START-UP VALVE, VALVE, SOFT START LOCKOUT, 241, 0.68000 lb
Body Size: 3000, Thread: N (NPT), Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)