/8, 1/2, 3/4 16-12-3 Series IFW5 IFW50--55 to 86 (With light, Terminal box for 24 VDC) n 2-3/8, 1/2, 3/4 16-12-4 Diaphragm Style Flow Switch Series IFW5 Internal Wiring Diagram Precautions IFW50--00/10/20 Be sure to read before handling.
V 12 V V 12-2 12-1 1. 1 2 2. 3.
V 12 V V 12-2 12-1 1. 1 2 2. 3.
Tubing size Symbol 03 04 03 04 05 06 07 06 08 10 07 11 10 12 11 13 12 13 19 Body class Tubing O.D. 1/8", 3 4 1/8" 4 3/16" 6 1/4" 6 8 10 1/4" 3/8" 10 12 3/8" 1/2" 12 1/2" 3/4", 19 Body class 1 Symbol 1 2 3 4 5 Body class 1 2 3 4 5 Type of part Symbol U B N Type of part Nut & Insert bushing Insert bushing Nut 2 3 4 5 505 Applicable Fluids Material and fluid compatibility check list for High
12 27 4-Rc 1/4 13.5 4-Rc 1/4, 3/8 VH32-02/03 (Bottom ported) 2 (A) 44 3 (R) 1 (P) 4-Rc 1/4, 3/8 4 (B) 5-8-10 5 Hand Valve Series VH Dimensions: Body Mounted VH40-02 to 04 VH40-06 ( ): Long handle type ( ): Long handle type 4 (B) 2 (A) 4 (B) 2 (A) 25 (32) 25 (32) 1 (P) 3 (R) 1 (P) 3 (R) SA 102 88 102 89 VA SA 4-6.6 VA 4-6.6 VM 81 88 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South
3.6-12 Series VH Panel Mounted/Dimensions VH41l-02 to 04 VH41l-06 2 (A) 4 (B) 4 (B) 2 (A) 25 25 3 (R) 1 (P) 3 (R) 1 (P) 107.5 19 l102 102 89 88 4-6.6 4-6.6 88 81 94 148 144 97 97 67 1.5 65 1.5 125 123 105.5 3 (R) 3 (R) 1 (P) 1 (P) 25 17 2 4-Rc1/4, 3/8, 1/2 4-Rc3/4 VH43l-02 to 04 (Bottom piping) VH43l-06 (Bottom piping) 2 (A) 2 (A) 46 54 1 (P) 3 (R) 1 (P) 3 (R) 4 (B) 4 (B) 4-Rc3/4 4
3/4, 1 3 (R) 40 5-8-12 Hand Valve Series VH Dimensions: Panel Mounted VH21-02 VH31-02/03 ( ): Long handle type 4 (B) 2 (A) 25 25 (32) 25 4 (B) SA 1 (P) 3 (R) 1 (P) 74 62 62 49 VA 2 (A) SA 49 4-5.5 4-6.6 VA 62 VM 134(159) VR 97(122) VH 125 94 VHS M40 x 1.5 8 (10) 1.5 M8 x 1.25 106(113) M33 x 1.5 8 45 1.5 M8 x 1.25 88.5 92 73 56 1 (P) 3 (R) 1 (P) 27 23 13.5 3 (R) 12 4-Rc 1/4, 3/8 12
04 04 04 1/2 4 + Nil Nil Nil Nil Without mounting option a Mounting B B B B With bracket H H H H With hexagon panel nut (for panel mount) + Pressure gauge Nil Nil Nil Nil Without pressure gauge Option Note1) G G G G Round type pressure gauge 5 EA EA EA EA NPN open collector 1 output b With digital pressure switch EB EB EB EB PNP open collector 1 output EC EC EC EC NPN open collector 1 output
JIS Symbol How to Order VR 12 1 06 0 F Body size Applicable tubing diameter Metric size Inch size 1 2 1/8 standard 1/4 standard 23 04 06 08 10 3.2 01 03 07 09 11 1/8" 5/32" 1/4" 5/16" 3/8" 4 6 8 10 Shuttle valve With One-touch fittings For 3.2, use 1/8" tubing. 5-7-5 63 Series VR1210F/1220F Example of Operating Circuit OR circuit Self-hold circuit Interlock circuit When either A or B is
With relief valve None 0 1 Port size Flange SSA 15 (1/2B) 20 (3/4B) 25 (1B) 32 (1 1/4B) 40 (1 1/2B) 50 (2B) 65 (2 1/2B) 80 (3B) Threaded Rc 3/8 1/2 3/4 1 1 1/4 1 1/2 Symbol 03 04 06 08 10 12 16 20 24 Replacement Element Part No.
Rc1/8 10 NPT1/8 12 12 12 G1/8 10 8 10 M50.8 12 10 12 11 - No.ZB-OM00301 V PV PD PD Assy PD PV PVPD OUT1 OUT1 ON OUT2 OUT2 ON LED ON/OFF UP ON/OFF DOWN S SET 12 - No.ZB-OM00301 () -550 0.0750.096Nm 10mm 1mm 13 - No.ZB-OM00301 1mm (11.8) KQ2L04-M5N 16 1 PV PD (11.8) KQ2H04-M5N KQ2L04-M5N KQ2W04-M5N ZB1-BK1-A M2x14 2 M22 KQ2L04-M5NKQ2H04-M5NKQ2W04-M5N 14 - No.ZB-OM00301
DC (+) 1 NC 2 Flow direction DC () 3 OUT 4 8 Digital Flow Switch for Water Series PFW How to order 20 03 27 PFW7 Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Wiring specifications 1l/min=0.0353SCFM 3m lead wire with connector Without lead wire Nil N Thread type Rc NPT G Nil N F Output specifications 27 67 NPN (2 outputs) PNP (2 outputs) Piping port size 03 04 06 3/8 1
Load proportion is ((load weight x 9.8)/theoretical force) x 100% Conditions of Speed Chart System A B C D E F G Solenoid valve Speed controller AS420-04 AS500-06 AS600-10 AS600-10 AS800-12 AS900-14 AS900-20 Tubing diameter x Length SGP15A x 1 m SGP20A x 1 m SGP25A x 1 m SGP25A x 1 m SGP32A x 1 m SGP40A x 1 m SGP50A x 1 m Silencer AN40-04 AN500-06 AN600-10 AN600-10 AN700-12 AN800-14 AN900
Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04
Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04
Note) Elbow 06 08 10 12 6 8 10 12 Control type Meter-out Meter-in 0 1 Note) For applicable tubing O.D. selection, refer to the Model on page 603. Port size With One-touch fitting 01 M5 M5 R 1/8 R 1/4 R 3/8 R 1/2 02 03 04 Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.
-04 AQ240F-04-00 12.9 14.3 5.2 39.2 6 4 9.3 5 4 10.0 9.3 39.2 5.2 13.7 23.5 12.9 12.9 AQ240F-06-06 AQ240F-06-00 13.7 15.4 6.2 40.7 8 6 6 10.0 11.6 6 11.6 40.7 6.2 14.7 26.7 13.7 13.7 AQ340F-06-06 AQ340F-06-00 13.7 19.5 6.3 44.8 13 6 6 11.8 11.6 11 11.6 44.8 6.3 19.6 31.7 13.7 13.7 AQ240F-07-07 AQ240F-07-00 13.7 15.4 6.2 40.7 8 10.0 1/4" 1/4" 12 6 12 40.7 6.2 15.1 27.3 13.7 13.7 AQ340F-07-
-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000-GS AV5000-D AV5000-DZ AV5000-Y AV5000-YZ M4 x 0.7 Depth 4.5 22 29 0 38 40 31 105 93 66 1/4 47.5 23.5 65.5 6 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 82.5 23 67.5 10.5 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 84.5 27.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 112 100 76 3/8 50.5 27.5
-04 42.4 Note 1) ( ) are the dimensions of NPT thread.
VP717 AC40-A Y400-A Y400T-A E400-04-A AN40-04 AN402-04 * Refer to page 3 for details of the spacer. 1 Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve VP500/700 Series Specifications Fluid Air Type of actuation N.C.