This produces an air cushion cylinder which retains the merits of a compact design. Operating principle q When the piston is retracting, exhaust is discharged from both A and A' until piston seal H passes the air passage A. A + A' A' w After piston seal H has passed the air passage A, exhaust is discharged only from A'.
Basic (Through-hole/Both ends tapped common): CQUB F Q 2 x M5 x 0.8 Y 4 x M6 x 1 depth 10 4 x 5.4 through 15 KA H H1 Rod end nut Width across flats B1 NY EY D X C1 K NX A + Stroke B + Stroke L EX L1 Rod end male thread Basic (mm) Size Stroke range (mm) A B D EX EY F H K KA L NX NY Q Y 20 25 32 40 5 to 50 49 42.5 10 22 47 11.5 M5 x 0.8 depth 8 5 8 6.5 5.5 36 15 3 5 to 50 49 42.5 10 24 53 11
C 1 B A Basic (mm) (mm) T 9 10.5 MKB20-Z MKB25-Z Model Yh9 18 23 A B C E F G 36 40 47 52 36 40 35.5 40.5 18 21 17.9 22.5 S 28 27.5 Clamp stroke Model Rod state 0 0.043 0 0.052 20 mm Q R 112.5 142 113.5 143 30 mm Q R 132.5 172 133.5 173 10 mm Q R 92.5 112 93.5 113 Retracted Extended Retracted Extended MKB20-Z 72 82 92 MKB25-Z 73 83 93 Note) The above figure is with the auto switch (D-M9) mounted
Note 6) Contact P/A regarding the set nuts for AR50 and AR60. 36 AR10 to 60 Flow Characteristics (Representative values) Condition: Inlet pressure 0.7MPa Specific Product Precautions AR10 M5 AR40 Rc 1/2 0.6 0.6 Be sure to read before handling.
A valve, which might potentially cause a hum or buzz can be very annoying to a patient, so a full wave rectified unit for AC service is often preferred. A DC unit, not requiring a rectifier, is sometimes used in specific applications. Also common is a bumper in a 2-way valve, usually just a flat disk with no sealing action.
2 M5 23 22.5 36 17 11 41 90 45 8 22 107 70 74.5 103 74.5 48 84 26 1/4, 3/8 VCB41 M5 23 25 36 17 13.5 41 94 50 8 30 111.5 70 78.5 103 78.5 48 88 26 1/2 M5 28.2 30 36 17 17.5 41 102 60 8 35 119 70 86.5 103 86.5 48 96 26 3/4 4 Direct Operated 2 Port for Heated Water Series VCB Model Selection VCB (for heated water) 2 port solenoid valve Class Orifice size mm Model Material Port size Body Seal
Mounting screw(M3) Tightening torgue 0.5 to 0.7Nm A DIN rail mount bracket fig. 3 When setting to DIN rail, place A of fig. 3 into DIN rail. While pushing it, fix it by the clamp of screw in fig. 4. Inadequate pushing may cause falling of parts.
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
Auto switch symbol (mm) (mm) S Bore size (mm) B Bore size (mm) h C A g N S 26.5 30 38 45 55 66 86 104 20 25 32 40 50 63 80 100 20 25 32 40 50 63 80 100 61 63 71 75 81 90 105 132 43 45 51 55 60 67 78 96 18 18 20 20 21 23 27 36 33 36 45 50 56 68 87 111 76 81 96 105 116 135 165 207 6 6 7 7 7 7 7 7 N g C B + Stroke h + Stroke A + Stroke Note) For all dimensions other than the above, please refer
HS A B Reed switch D-A7H D-A80H Solid state switch D-F7 D-J79 D-F7W D-J79W D-F7BAL D-F79F D-F7NTL 32/40/50 (mm) D-F7 D-J79 D-F7 W D-F79F D-J79W D-F7BAL D-A7 H D-A80H D-F7NTL Auto switch model A B Hs 9.5 13.5 11.5 Symbol A B Hs A B Hs 32 40 50 32.5 36 42 11.5 14 17 14.5 18.5 16.5 32.5 36 42 32.5 36 42 6.5 9 12 6.5 9 12 9.5 13.5 11.5 Bore size (mm) Solid state switch D-P5DW A B HS (mm) D-P5DW
model Auto switch model D-G59F D-G5 D-K59 D-G5W D-K59W D-G5NTL D-G5BAL D-C7 D-C80 D-H7 D-H7W D-H7NF D-H7BAL D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-H7C D-H7 D-H7C D-H7NF D-H7W D-H7BAL D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-C7 D-C80 D-C73C D-C80C D-A9 D-M9 D-M9W D-M9 D-M9W D-B5 D-B64 D-B59W D-C73C D-C80C D-A9 Bore size (mm) Bore size (mm) Hs Hs Hs Hs Hs A B A B A B A B A B 16 (24) A B A A
132 8 20 CU Data Bore size (mm) L B + Full stroke RR CW CX+0.2 +0.4 CX CZ RR CL + Full stroke CZ -0.3 -0.1 32 18 36 10 A + Full stroke 40 18 36 10 50 22 44 14 63 44 22 14 10-10-11 12 Series RZQ Proper Auto Switch Mounting Position (For Detection of Piston A Stop Position) and Its Mounting Height D-A7 D-A80 U B + First-stage stroke U B A Courtesy of Steven Engineering, Inc.-230 Ryan Way,
bore size D-P5DW 40, 50, 63 B + First-stage stroke =U =U Mounted on different side in case of a full stroke of 25 mm or less B A [mm] Proper mounting position D-A7H,A80H D-A73C,A80C D-F7,J79,J79W D-F7V,J79C D-F7W,F7WV D-F7BAL,F7BAVL D-F79F D-F9 D-F9V D-F9W D-F9WV D-A79W D-F7LF D-A9 D-A9V D-F9BAL D-P5DWL D-A7,A80 Bore size (mm) A B A B A B A B A B A B A B A B 32 29 39.5 30 40.5 26 36.5 31.5
Dimensions (mm) 1in = 25.4mm MSUA7 MSUA7-S, SE Scale: 60% Top ports/MSUA7-SE C 8-M4 x 0.7 depth 8 A port B port 67 13 2-M5 x 0.8 14 B 41 50 33 37 4-M5 x 0.8 depth 7 22.5 5 +0.025 0 3H9 A Long groove depth 5 (positioning pin hole) 22.5 47h9 0 0.062 +0.052 0 26H9 36 +0.030 0 3-4H9 depth 4 ( A , B , C ) 4 3 2-5.5 through 3-R2 3-R2 4.5 19 10.5 13 48h9 0 0.062 36 7 6 22.3 10.5 44 3 11 10 58.5
(mm) Type Port size Model Type Port size Model KQ2H04-M5 KJH04-M5 Male connector Male connector 4 M5 x 0.8 KQ2S04-M5 4 M5 x 0.8 KJS04-M5 Hex. socket head male connector Hex. socket head male connector KQ2L04-M5 KJL04-M5 Male elbow Male elbow Miniature Fitting/Series M Tubing O.D.
38 35 42 40.5 A 33 32.5 34 31 38 36.5 49.5 48.5 A B A B A B A B 20 25 32 40 50 63 80 100 B 24 (32) 24.5 (32.5) 25 (33) 27 (36) 32 (44) 33.5 (45.5) B 14.5 (22.5) 15 (23) 15.5 (23.5) 17.5 (26.5) 22.5 (34.5) 24 (36) 29 (43) 30 (44) B 20 (28) 20.5 (28.5) 21 (29) 23 (32) 28 (40) 29.5 (41.5) B 16 (24) 16.5 (24.5) 17 (25) 19 (28) 24 (36) 25.5 (37.5) 30.5 (44.5) 31.5 (45.5) Hs 27.5 30 33.5
When mounting the cylinder body with mounting bolts, use the tightening torques in the table at right as a guide. Mounting bolt Tightening torque Size Nm Qty. Bore size (mm) 20 32 40 50 63 80 100 M5 x 0.8 M5 x 0.8 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M10 x 1.5 2 4 4 4 4 4 4 3 3 3 6 11.5 24 34 7.
Width across flats D A5 M5 x 0.8 A6 M6 x 1 15.5 C A Model A B C D Vacuum inlet direction q Pad dia.