1/4 GaugePort D 53 70 Q 46 54 L 41 50 J 239(max.242) 276(max.280) K 59 75 U 40 54 V 53 70 A NPT 3/8 NPT 1/2 W 2.3 2.3 X M38 X 1.5 M42 X 1.5 DD 34.5 41 CC 38.5 42.5 E 30 38 F 83(max.86) 88(max.92) T 8 10.5 Y 31 35.5 Z 7 7 AA 19 21 H 3.5 1.5 S 6.5 8.5 AW30 AW40 6 Series AW20~40 Filter Regulator Standard (Manual Drain) PANEL FITTING IN OUT Z CC Bowl Detail EE (AW20) AA K L V U X W T J S Y Q
Basic type (B)/CJ5BS NDn8 GA GB Piping port 2-M5 x 0.8 Piping port M5 x 0.8 MM NN CA CB D F NA NB A With head cover port in axial position (R) BA BB H S + Stroke Z + Stroke (mm) Bore size (mm) A BA BB CA CB D F GA GB H MM NN NA NB NDn8 S Z 0 0.022 0 0.027 10 15 15 12 17 14 4 8 8 5 28 M4 x 0.7 M10 x 1.0 12.5 9.5 10 46 74 16 15 18 18 20 20 5 8 8 5 28 M5 x 0.8 M12 x 1.0 12.5 9.5 12 47 75 R V
Confirm the Coordinates and Moments in Model Selection on page 1229 for details of floating Y and Z axes. 1196 MY1B Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) MY1B (Basic type) 25 to 40 Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model D-A9 D-A9V A A Bore size A 25 32 40 79 83 112.5 116.5 133.5
HS Auto switch Auto switch 12 8.5 24.5 16 A B A B 33 38.2 Auto switch mounting position Auto switch mounting height (mm) (mm) Auto switch model D-C7, C8 D-H7 D-H7W D-H7F D-H7BA D-H7 D-H7C D-H7W D-H7BA D-C7, C8 D-C73C D-C80C D-B5, B6 D-C73C D-C80C D-B5, B6 D-B59W D-G5NT D-H7C D-G5NT D-B59W D-H7F Bore size (mm) A A B A B A A HS HS HS B B B B A 20.5 (28.5) 14.5 (22.5) 17.5 (25.5) 19.5 (27.5)
Note D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F7BAVL D-F79F D-F7NTL Switch mounting screw RS H A 20, 25 BQ-1 (M3 x 0.5 x 8l) Square nut D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W RZQ Switch mounting screw 32, 40 50, 63 Magnetic body (Steel plate, etc.)
, D-F9WV D-M9, D-F9W D-M9V D-A9V D-F9BAL CQ2 No. of auto switches mounted 1.
OIl-Delay time 200 +/50mS Series CD5 Auto Switches D-A64 D-A59W D-853, A53 Reed Type Internal Circuit ~"e C) t ~R.o Reed sWltch Luminous diode Z"'" diode Zener dtlXle Surge absOtber D-A54, D-A44 D-A67 Reed sw~ch Zener dlode Indicator light I Operation R., ON Black (+) OperaUng (-) "'"!
Basic type (B)/CJ5BS NDn8 GA GB Piping port 2-M5 x 0.8 Piping port M5 x 0.8 MM NN CA CB D F NA NB A With head cover port in axial position (R) BA BB H S + Stroke Z + Stroke (mm) Bore size (mm) A BA BB CA CB D F GA GB H MM NN NA NB NDn8 S Z 0 0.022 0 0.027 10 15 15 12 17 14 4 8 8 5 28 M4 x 0.7 M10 x 1.0 12.5 9.5 10 46 74 16 15 18 18 20 20 5 8 8 5 28 M5 x 0.8 M12 x 1.0 12.5 9.5 12 47 75 R V
D A 7 S | V x 2 5 0 Metric protective sleeve, (r{) lll.r, Nn/hour model Weigli (kcl DA5(}lltx?
model S D-Y7W(V) D-Y59 D-Y69 D-Y7P(V) 1 Red light at ON Greeen light at ON MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D 4 4 13 4 4 10 2 2 7 2 2 5 2 2 4 12-10-24
model S D-Y7W(V) D-Y59 D-Y69 D-Y7P(V) 1 Red light at ON Greeen light at ON MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D 4 4 13 4 4 10 2 2 7 2 2 5 2 2 4 12-10-24
CJ5 CG5 DC Auto switch model Lead wire length (m) Type Electrical entry Wiring (Output) Load voltage Indicator light Pre-wired connector 3 (L) 5 (Z) Applicable load 0.5 (Nil) HY C M F6N 3-wire (NPN) 5 V 12 V IC circuit Solid state switch Relay, PLC F6P 24 V Yes Grommet 3-wire (PNP) F6B 12 V 2-wire Lead wire length symbols 0.5 mNil (Example) F6B 3 m L (Example) F6BL 5 m Z (Example) F6BZ
Auto Switch Proper Mounting Position for Stroke End Detection MY1CW 16, 20 MY1MW 16, 20 B A Reed switch D-A90(V), D-A93(V), D-A96(V) Solid state switch D-F9N(V), D-F9P(V), D-F9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) Mounting position 20 16 20 16 20 Mounting position Mounting position 16 A 90 70 93 73 94 A A 74 B 110 90 107 87 106 B B 86 Operating range Note) 7.5 11 6.5 8.5 6.5 Operating range
Left Left View Z 1 port side 2 port side 1 port side 2 port side 1 port side 2 port side Right Right View Z L W Note) When using a bracket whose direction is the same as that of the pilot valve, ensure that the installation surface does not get in the way of the pilot valve. T: Conduit terminal D/DO: DIN terminal W/V: M12 connector L Product specifications Series W W L W L N.C.
A B C D Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Note Model LJ1H202PC-500LJ1H202PC-600LJ1H202PC-700LJ1H202PC-800LJ1H202PC-900LJ1H202PC-1000700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-1B2H1Power supply: 200/220(V)AC 10% Compatible controller
Proper Auto Switch Mounting Position (Detection at stroke end) MX A B MTS MY MY3A D-A9, D-A9V (mm) D-F9W, D-F9(W)V (mm) D-M9, D-M9V (mm) CY A B Operating range Bore size 16 25 40 63 A B Operating range Bore size 16 25 40 63 B Operating range Bore size 16 25 40 63 A 088.5 084.5 26.5 084.5 22.0 26.5 2 06.5 3.0 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080
(V), D-A93(V), D-A96(V) Auto Switch Specifications Grommet Electrical entry: In-line D-A90, D-A90V (without indicator light) Auto switch part no.
When mounting D-A9(V)/M9(V)/M9W(V)/M9A(V)L types on a side other than the port side with 32 to 50 cylinders, order auto switch mounting brackets separately.
T) LVA V LVH M N LVD LVQ30, LVQ50 V SMC LVQ SMC B A SMC C LQ B A U D LVN Z (Max. T) TI/ TIL PA M N PAX LVQ40, LVQ60 PB C B A D (Max.
HS Auto switch Auto switch 12 8.5 24.5 16 A B A B 33 38.2 Auto switch mounting position Auto switch mounting height (mm) (mm) Auto switch model D-C7, C8 D-H7 D-H7W D-H7F D-H7BA D-H7 D-H7C D-H7W D-H7BA D-C7, C8 D-C73C D-C80C D-B5, B6 D-C73C D-C80C D-B5, B6 D-B59W D-G5NT D-H7C D-G5NT D-B59W D-H7F Bore size (mm) A A B A B A A HS HS HS B B B B A 20.5 (28.5) 14.5 (22.5) 17.5 (25.5) 19.5 (27.5)