SMC Corporation of America
Elite Part Number Search
Search Results "25A-MGPM16-100Z-A90L"

Operate in a range such that the cylinder pressure is less than two times the supply pressure. 00 51 Applicable solenoid valve 1 2 VQ54 VQ5 VVQ5000-25A-1 (plug-in type) VVQ5000-25A-5 (plug lead type) Can hold an intermediate cylinder position for an extended time When combined with a double check spacer with built-in double check valve, it is unaffected by air leakage between the spool valves

Magnet: Built-in Magnet, Mounting: Clevis, Type: Air Cushion, Bore: 32mm, Port Thread Type: TN [NPT ø20 to ø100 Rubber Bumper, ø32 to ø100 Air Cushion), Stroke: 100mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewire Connection: 3m, Number: -, X Option: -

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Magnet: D (Built-in Magnet), Mounting: D (Clevis), Type: A (Air Cushion), Bore: 32mm, Port Thread Type: TN [NPT ø20 to ø100 Rubber Bumper, ø32 to ø100 Air Cushion), Stroke: 100mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: W (Double Knuckle Joint), Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewire Connection: L (3m)

(The lock cable is included when the motor with lock option is selected.) 11LEJS 25A*6 The length of the motor, encoder and lock cables are the same. o I/O cable length [m] *7 LEC Nil Without cable H Without cable (Connector only) 1 1.5 LEC S *4 When the driver type is selected, the cable is included.

5 11LEJS Motor option: With lock 25A!1 LEC !2 LEC S !3 LEC SS-T @0 LEC Y !9 Motorless LAT Component Parts Component Parts LZ No. Description Material Note 1 Body Aluminum alloy Anodized No.

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.  25A-ZSE20C(F) is a digital vacuum sensor offering compatibility with both compressed air and non-corrosive liquids.  Compared to the 25A-ZSE20, 25A-ZSE20C(F) adds a 2nd switch output, as well as analog voltage or current output. 

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.  25A-PFM5 is a digital flow sensor compatible with air, nitrogen, argon and carbon dioxide.  This is the remote version of 25A-PFM7, without a display.  The top panel includes two LEDs to indicate power and flow functions. 

Bracket mounting inserts found on the standard ZSE20A are omitted as well.  25A-ZSE20A(F) is UL/CSA, CE and RoHS compliant, with an IP40 enclosure rating.

Bracket mounting inserts found on the standard ISE20B are omitted as well.  25A-ISE20B is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.

Bracket mounting inserts found on the standard ZSE20B(F) are omitted as well.  25A-ZSE20B(F) is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.  25A-ZSE20C(F) is a digital vacuum sensor offering compatibility with both compressed air and non-corrosive liquids.  Compared to the 25A-ZSE20, 25A-ZSE20C(F) adds a 2nd switch output, as well as analog voltage or current output. 

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.  25A-PFM5 is a digital flow sensor compatible with air, nitrogen, argon and carbon dioxide.  This is the remote version of 25A-PFM7, without a display.  The top panel includes two LEDs to indicate power and flow functions. 

N.C. 6A 8A 10A 10A 15A 20A 25A 32A 32F 40A 40F 50A 50F 1 8 1 4 3 8 3 8 1 2 3 4 7 1 15 2 20 3 25 4 1 1 1 4 32 5 11 4 B Flange 11 2 40 6 11 2 B Flange 2 50 7 2B Flange 634 Steam Valve: 2 Port Valve For SteamVND Series Model Port size Flow rate characteristics Weight (kg) Orifice dia.