Station 9 SOL.B 22 SOL.A 10 Station 10 SOL.B 23 SOL.A 11 Station 11 SOL.B 24 SOL.A 12 Station 12 SOL.B 25 Note) COM. 13 VV5Q21 Positive COM spec. Negative COM spec. The total number of stations is tabulated starting from station one on the D-side. Note) When using the negative common specifications, use valves for negative common. (Refer to page 56.)
[C] [60 Hz] 0 10 20 30 40 50 Circulating fluid temperature [C] HRS018-A-10/HRS018-W-10 (Single-phase 100/115 VAC) 2500 2500 25C Cooling capacity [W] Cooling capacity [W] 25C 2000 2000 32C 1500 1500 32C 40C 1000 1000 40C 500 500 Ambient temperature or facility water temperature Ambient temperature or facility water temperature 0 0 [50 Hz] 0 10 20 30 40 50 Circulating fluid temperature [C]
11 11 13.5 13.5 16 20 20 20 24 6.6 9 9 11 11 11 11 11 14 16 16 14 22 24.5 28.5 28.5 35.5 35.5 35.5 44.5 44.5 53 65 65 56 78 For 3.5 MPa hydraulic cylinders, operate within the maximum tension and compression force. 10-19-6 7 Floating Joint: Heavy Load Type Series JAH Specifications Specifications RE A B Applicable cylinder nominal thread size Maximum operating tension and compression force
11 11 13.5 13.5 16 20 20 20 24 6.6 9 9 11 11 11 11 11 14 16 16 14 22 24.5 28.5 28.5 35.5 35.5 35.5 44.5 44.5 53 65 65 56 78 For 3.5 MPa hydraulic cylinders, operate within the maximum tension and compression force. 10-19-6 7 Floating Joint: Heavy Load Type Series JAH Specifications Specifications RE A B Applicable cylinder nominal thread size Maximum operating tension and compression force
12 13 14 15 1 0 1 2 3 4 5 6 8 9 10 11 13 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 7 12 Distance from cylinder shaft center: L0 (cm) Distance from cylinder shaft center: L0 (cm) Distance from cylinder shaft center: L0 (cm) 50 63 1000 1000 Recommended driving force: Fn(N) Recommended driving force: Fn(N) 500 400 500 200 300 300 200 Usable range 100 100 Usable range 20 30 40 50 50 40 30 20 10
200, 250, 300 63 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100 MGGL Ball bushing 80 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200 100 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
1 Output Nil None B Adapter assembly for bottom mounting*11 (Included) Nil None A NPN open collector B PNP open collector GN With vacuum pressure detection (G) port (Rc1/8, G1/8, NPT1/8)*6 *11 This adapter assembly is for adjusting the product to the 27 mm pitch of the bottom mounting thread of the existing ZL212 series model.
2 e (1 pc.) @0 10-11-11 11 Series MIW/MIS Dimensions: Double Finger Type MIW-D 2-P Supply port 3-LA Scraper mounting thread EB FB NB ME PE GD LB JA B FA FC GC GB JB Mounting hole 4-GA LC C EA D 2-P Attachment mounting thread 4-FD through Supply port PD NA FF FE PC PA A Mounting threads 4-MA thread depth MB Groove position for auto switch mounting HB depth HC HD (2 pcs.)
-12-150 JA40-12-175 JA50-16-150 JA63-16-200 JA80-20-250 JA100-24-300 JA100-27-150 JA125-27-200 JA160-33-200 20 25 32 32, 40 40 32, 40 50 50, 63 80 100 100 125 160 1100 2500 2500 4400 4400 4400 11000 11000 18000 28000 28000 28000 71000 13 17 17 22 22 22 27 27 32 41 41 41 55 7 8 8 11 11 11 13.5 13.5 16 20 20 20 24 7 8 8 11 11 11 14 14 19 24 24 24 36 4.5 5 5 6 6 6 7.5 7.5 9.5 11.5 11.5 13 16
2 e (1 pc.) @0 10-11-11 11 Series MIW/MIS Dimensions: Double Finger Type MIW-D 2-P Supply port 3-LA Scraper mounting thread EB FB NB ME PE GD LB JA B FA FC GC GB JB Mounting hole 4-GA LC C EA D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2-P Attachment mounting
Make a model selection, considering a load according to the graph on page 8-19-11.
M12 connector (for socket), 10 pcs. 4 3 Socket connector pin arrangement 11 14 Terminal no.
empty weight deflection 2 2 Lateral empty weight deflection Lateral empty weight deflection 1 1 0.5 0.5 0.2 0.2 0.1 0.1 200 300 500 1000 100 Load point distance mm 200 300 500 1000 100 Load point distance mm 146
Conditions: Ion generation frequency 30 Hz Supply pressure: 0.1 MPa High speed static neutralization cartridge Discharge time = 3.2 seconds (41% shortened) when installed at long distance (1000 mm) 11 10 9 8 7 6 5 4 3 2 1 Discharge time (s) Current model 41% IZS40 0 0 500 1000 1500 2000 Installation distance (mm) 412 Ionizer (High speed static neutralization specification) Feedback sensor
Operating Parameters Status Gas Operating pressure Proof pressure Burst pressure Ambient and operating temperature Cv Vacuum to 250 psig (1.7 MPa) Vacuum to 125 psig (0.9 MPa) 1000 psig (6.9 MPa) 8000 psig (55.2 MPa) 14 to 160F (10 to 71C) (No freezing) 1) 0.29 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 2) 4 x 10-9 Pam3/sec 2) Ra max 15 in. (0.4 m) Option: 10 in. (0.25 m), 7 in. (0.18 m), 5 in
R1 1.5 RA 10 * R3 3 RB 15 * R5 5 RC 20 * Applicable Stroke Table *Produced upon receipt of order Stroke Size 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 Controller *Refer to catalog 16 25 32 40 Caution The actuator body and controller are sold as a package.
How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)
AS3201F, AS3211F AS3301F, AS3311F AS4201F, AS4211F AS4301F, AS4311F Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 12, 13, 16 10, 11, 12 1500 1000 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 08, 09 06, 07 1000 500 500 0 0 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Note) The numbers above the flow rate characteristic curves in the charts show the applicable
11 Common for each auto switch Since this is a guideline including hysteresis, not meant to be guaranteed.
Station 9 SQ SOL.B SOL.A 23 10 Station 10 SOL.A VFS SOL.B 24 11 Station 11 SOL.B SOL.A 25 12 Station 12 VFR VV5Q21 COM. () Orange Red (+) 13 VQ7 Positive COM spec. Negative COM spec. The total number of stations is tabulated starting from station one on the D-side. Note) When using the negative common specifications, use valves for negative common. (Refer to page 419.)