Furthermore, when mounting supply/exhaust block assemblies on both sides of type B with a 2 to 10 station manifold, calculate the weight W using the formula for 11 to 16 stations.

(Except cushion seal) Cushion ring B Rolled steel Zinc chromated Cushion valve Rolled steel Electroless nickel plated Rod seal SKY-36 SKY-36 SKY-40 @5 @6 NBR Spacer A Rolled steel Zinc chromated Piston seal RPS-125 RPS-140 RPS-160 Spacer B Rolled steel Zinc chromated Replacement Parts (Seal kits) Air releasing valve B Rolled steel Zinc chromated Air releasing valve A Chrome-molybdenum steel

A B 3 5.5 7 7 15 60 65 + 45 (n-2) D-H7, D-H7W D-H7F 30.5 28.5 30 30 n-2 2 15 + 50 ( ) (n = 2, 4, 6...) Approx. Hs 30.5 35 40.5 47.5 D-H7C 15 65 10 65 + 50 (n-2) A B Approx. Hs 3 5.5 7 7 n-2 2 D-H7C 31.5 28.5 30 30 15 + 50 ( ) (n = 2, 4, 6...)

plane 52.5 Stroke + 386 1 125 3(2) x 8H10 depth 10 thread depth 10 8(4) x M6 x 1 30 95 B 95 100 8(4) x 6.2 (170) () () 20 95 A 95 110 (150) () () The body mounting reference plane and work A B Stroke Model piece mounting reference plane should be used as standards when mounting onto equipment.

One-touch fitting) A port M3 x 0.5 M3 x 0.5 Flow Rate Characteristics Flow rate characteristics Effective area (mm2) Port size 12 (PA) 23 (AR) Manifold C [dm3/(sbar)] 1(P), 3(R) Port 2(A) Port b Cv C [dm3/(sbar)] b Cv Body ported for internal pilot 0.9 M3 x 0.5 Type 10-SS3YJ3-20 10-SYJ32M M5 x 0.8 Type 10-SS3YJ341 S41 10-SYJ34M M5 x 0.8 1.5 M3 x 0.5 Type 10-SS3YJ3-42-M5 Type 10-SS3YJ3-42-

No.5 No.6 No.7 No.8 No.9 No.10 32 16 8 4 2 1 0 0 0 0 0 0 0 1 0 0 0 0 0 1 MAC ID 2 0 0 0 0 1 0 : : : : : : : 62 1 1 1 1 1 0 63 1 1 1 1 1 1 Communication speed setting (switches No. 3 to 4) The DeviceNet communication speed is binary coded and can be set to 125 kbps, 250 kbps and 500 kbps. : Factory default setting is 125 kbps. 0: OFF 1: ON Switch No.

FT FD B Port 4-FD CS1 32 40 50 63 80 100 up to 500 157 149 79 32 64 10 7 50 up to 500 171 158 90 36 72 10 9 55 up to 600 188 176 110 45 90 12 9 70 FY B up to 600 188 176 120 50 100 12 9 80 up to 750 238 220 153 63 126 16 12 100 FT FX up to 750 238 220 178 75 150 16 14 120 ZZ + Stroke FZ Single clevis(C)/Locking at head end (Hl) Wl Hl/ Rl (mm) Port Cushion valve Stroke range Bore size (mm

If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. 8 Filter Rc1 20m Refer to the table below * Recommended filters for facility water inlet Applicable model Recommended filter HRSH100/150 FQ1012N-10-T020-B-X61 Note HRSH200/250 FGESA-10-T020A-G2 Note Note) The filter shown above cannot be directly connected to the thermo-chiller.

Bore size (Stroke (mm)) 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 6 8 12 16 20 25 Functional option Standard With buffer With end lock Axial piping type With buffer and end lock With buffer, Axial piping type Nil F R (2) P FR (2) FP Adjuster option Note

Cap bolt Bore size (mm) Hole: CD H10 d9 A B CD CL CT CU CW 112.5 82.5 10 102.5 5 14 20 32 10 6 14 22 124 92 114 40 14 7 20 28 134.5 96.5 124.5 50 146 102 14 132 8 20 30 63 CU Bore size (mm) L B + Full stroke RR CW CX+0.2 +0.4 CX CZ RR CL + Full stroke CZ -0.3 -0.1 18 36 10 32 A + Full stroke 18 36 10 40 22 44 14 50 22 44 14 63 10 Series RZQ Auto Switches Proper Mounting Position(For Detection

Description Type Model ALB900-10 ALB900-20 ALB900-30 Bypass lubrication adapter AWD ALBA90-10 ALBA90-20 ALBA90-30 Standard attachment Ball valve B B IS440-1 to 2 1 4 ITV Ball valve 1 2 Oil can be replenished by merely opening and closing the oil filler plug without stopping the air line.

125 14-150 18-150 1 Series JS Construction 10, 16 20 to 63 Parts list Parts list No.

It same for mounting bracket {Refer to Table 10 (P30)} Short Long Table 8. Tightening torqueA 1 3 5 Bore size Width across flats Tightening torque[Nm] 32,40 6 5.1 50,63 8 11.0 80,100 10 25.0 2 4 125 12 30.1 Tie rod tightening order. 26 3-2-2. Removal of seals 1) Rod seal Insert a precision screwdriver from the front of the cover to pull out the seal as shown in Fig. 10.

Memory map of input data Data (2 byte) Input area Branch connector (INPUT) MSB LSB MSB LSB 15 8 7 0 byte (b+1) byte (b) Word (a) COM A byte (b+3) byte (b+2) Word (a+1) COM B byte (b+5) byte (b+4) Word (a+2) COM C byte (b+7) byte (b+6) Word (a+3) COM D byte (b+9) byte (b+8) Word (a+4) GW unit status information byte (b+10) byte (b+11) Word (a+5) (a, b=0 to) : Only when the GW unit status

10 to 0 (LSB) X bits 10 to 0 of COB-ID : The default values when the SI unit is supplied.