DSM-60S DSM-75S Cast iron DSM-75S(H) Piston r t y u i o !
Terminal q DC (+) w N.C e DC () r IN (1 to 5 V) e w q Power supply/Output connection cable (Accessory) Power supply/Output connector (8P) Pin no. 7 Green 8 Yellow 6 Red 5 Gray 4 White 3 Black 2 Blue 1 Brown i u y t r e w q Pin no.
135 180 4-11 225 (266) (60) AIR VENT G 1/4 q q A (43) OUT IN e e 150 r B t 120 327 188 (519) w w 84 OUT 2-R 1 r IN 53 DRAIN G 1/4 Note Parts list Dimensions (mm) A B No.
10VA 5W AC1500V1 AC500V 1 DC500V50 0+50 3585RH 1500V600V Hz 2 10G XYZ 3 250g 6 6 6 6 6 6 6 6-1 1 1 1 (DC12V60mA) B A G N D A B COM RS COM COM 12V G N D A B COM OUT1 AC100V OUT2 COM COM OUT3 COM DC24V GND AC100V (C E U 1) (C E U 1-D ) CEU1 +12V + 12V 1 A 680 CO M +12V + 12V 1 B 680 COM +12V D C 1 2 V60 m A GND RS COM FG AC100V 6 6 6 6-3 3 3 3 1C E U 1 CE1-R**
d e XAH7 XC XL X Section XX detail Bore size (mm) a b c d e 40 6.5 4 11 5.5 10.5 WB Z WA Section XX 8.5 50 4.5 13.5 7.5 13.5 11 7 18.5 63 10 17.8 Bottom view L 4-OA through 4-OB counter bore depth OL Section XX WA Z Section XX IA 4-NN through IC 4-MM depth ML R X0.02 HA T-slot for hexagon bolt X0.02 DA DB mIB ID X U VB VA H T PW 2-Rc P (plug) Rc 1/8 unlocking port Unlocks when pressurized
Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: None, Operation Manual: w/o Operation Manual, Calibration Certificate
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -