Specifications Particulate generation grade Grade 1 Note 1) Fluid Air Series KPQ Brass (electroless nickel plated) Release button: Light gray Maximum operating pressure (20C) 1MPa Note 2) Operating vacuum pressure 100kPa Proof pressure (20C) 3MPa Ambient and fluid temperature 5C to 60C Threads JIS B0203 (Taper thread for piping) Note 1) Refer to particulate generation grade classifications
Take measures to prevent freezing when below 5C, since moisture in circuits can freeze and cause damage to seals and lead to malfunctions. Refer to SMCs Air Preparation System catalog for further details on compressed air quality. Caution 1.
At temperatures of 5C or lower, take measures to prevent freezing, since moisture in circuits may be frozen and this can cause damage to seals and lead to malfunction. Refer to SMCs Air Cleaning Equipment catalog for further details on compressed air quality. Piping Caution 1.
Specifications Grade 1 Note 1) Particulate generation grade Air Fluid Series KPQ Brass (electroless nickel plated) Release button: Light gray 1MPa (145 psi) Note 2) Max operating pressure 20C (68F) 100kPa (-14.5 psi) Operating vacuum pressure 3MPa (435 psi) Proof pressure 20C (68F) 5C to 60C (23F to 140F) Ambient and fluid temperature JIS B0203 (taper threads for piping) Threads Note 1) Refer
Take measures to prevent freezing when used at 5C or less, since moisture in circuits can freeze and this may cause malfunction. Refer to the "Air Cleaning Equipment" catalog for details on compressed air quality. 5. Do not use equipment until you verify that it can operate properly.
Specifications Grade 1 Note 1) Particulate generation grade Air Fluid Series KPQ Brass (electroless nickel plated) Release button: Light gray 1MPa (145 psi) Note 2) Max operating pressure 20C (68F) 100kPa (-14.5 psi) Operating vacuum pressure 3MPa (435 psi) Proof pressure 20C (68F) 5C to 60C (23F to 140F) Ambient and fluid temperature JIS B0203 (taper threads for piping) Threads Note 1) Refer
MXP6 MXP8, 10, 12, 16 L2 L2 Shock absorber model RB0805 RB0805 RB0806 Applicable size MXP10 MXP12 MXP16 L2 Table 2 L2 (mm) 10 (one side only) 10 (one side only) 9 8 9 8 8 8 8 8 Model MXP6-5C MXP6-10C MXP8-10C MXP8-20C MXP10-10C MXP10-20C MXP12-15C MXP12-25C MXP16-20C MXP16-30C Stroke Adjustment Urethane bumper Lock nut Lock nut MXP6 MXP8, 10, 12, 16 Shock Absorber Loosen the lock nut, adjust
6 -X 20t e o !8 q !1 Data (Piston part) @3 y i e w y @3 i @3 y y i CXSWL1015 CXSW6 CXSW10 CXSW25, 32 Component Parts Note Nickel plated Note Hard anodized Hard chrome plated Hard chrome plated Description Material Special steel Synthetic resin Synthetic resin Polyurethane Chromium steel Aluminum alloy NBR NBR NBR NBR No. q w e r t y u i o !
225 2A 43 4A 10.8 0B 204 2B 41 4B 10.4 0C 187 2C 40 4C 10 0D 173 2D 38 4D 9.7 0E 160 2E 37 4E 9.4 0F 150 2F 36 4F 9.1 10 140 30 35.2 50 8.8 11 132 31 33.1 51 8.3 12 125 32 31.3 52 7.8 13 118 33 29.6 53 7.4 14 112 34 28.1 54 7.0 15 107 35 26.8 55 6.7 16 102 36 25.6 56 6.4 17 97 37 24.5 57 6.1 18 93 38 23.4 58 5.9 19 90 39 22.5 59 5.6 1A 86 3A 21.6 5A 5.4 1B 83 3B 20.8 5B 5.2 1C 80 3C 20.1 5C
Take measures to prevent freezing, since moisture in circuits can be frozen below 5C, and this may cause damage to seals and lead to malfunction. Refer to SMCs Best Pneumatics vol. 4 for further details on compressed air quality. 14 Series MLU Auto Switch Precautions 1 Be sure to read before handling. Design and Selection Warning 1. Confirm the specifications.
Take measures to prevent moisture from freezing in a piping circuit when using at 5C or less, since this may cause damage to the product and lead to malfunction.
31 1 81 51 Q 113 71 q 18 12 DC2 50 32 2 82 52 R 114 72 r 19 13 DC3 51 33 3 83 53 S 115 73 s 20 14 DC4 52 34 4 84 54 T 116 74 t 21 15 NAK 53 35 5 85 55 U 117 75 u 22 16 SYN 54 36 6 86 56 V 118 76 v 23 17 ETB 55 37 7 87 57 W 119 77 w 24 18 CAN 56 38 8 88 58 X 120 78 x 25 19 EM 57 39 9 89 59 Y 121 79 y 26 1A SUB 58 3A : 90 5A Z 122 7A z 27 1B ESC 59 3B ; 91 5B [ 123 7B { 28 1C FS 60 3C < 92 5C
If the fluid temperature is 5C or less, the moisture in the circuit could freeze, causing damage to the seals and equipment malfunction. Therefore, take appropriate measures to prevent freezing. Operating Environment Warning (1) Do not use in an atmosphere containing corrosive gases, chemicals, sea water, water, steam, or where there is direct contact with any of these.
If the fluid temperature is 5C or less, the moisture in the circuit could freeze, causing damage to the seals and equipment malfunction. Therefore, take appropriate measures to prevent freezing. 9 - Operating Environment 1. Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, steam, or Warning where there is direct contact with any of these.
If the fluid temperature is 5C or less, the moisture in the circuit could freeze, causing damage to the seals and equipment malfunction. Therefore, take appropriate measures to prevent freezing. 9 - Operating Environment 1. Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, steam, or Warning where there is direct contact with any of these.
Take measures to prevent freezing, since moisture in circuits may freeze at, or below 5C and this can cause damage to seals and lead to malfunctions. Refer to SMCs Air Cleaning Equipment catalog for further details on compressed air quality. 1. When operating at high speed with a large load weight, a large amount of energy is applied to the actuator and can cause damage.
Take measures to prevent freezing, since moisture in circuits will be frozen under 5C, and this can cause damage to seals and malfunction. Refer to SMCs clean pneumatic series Air Cleaning Equipment catalog for further details on compressed air quality. Operating Environment Warning 1. Do not use in environments where there is a danger of corrosion.
Spring return Model C Mounting bolt Model C Mounting bolt D 35 40 40 45 40 45 40 45 40 45 45 50 55 65 D 40 45 40 45 40 45 40 45 40 45 45 50 55 65 CDQ2B12-5S -10S CDQ2B16-5S -10S CDQ2B20-5S -10S CDQ2B25-5S -10S CDQ2B32-5S -10S CDQ2B40-5S -10S CDQ2B50-10S -20S CDQ2B12-5T -10T CDQ2B16-5T -10T CDQ2B20-5T -10T CDQ2B25-5T -10T CDQ2B32-5T -10T CDQ2B40-5T -10T CDQ2B50-10T -20T M3 x 35l x 40l M3 x
Model C Mounting bolt Model C Mounting bolt D 35 40 40 45 40 45 40 45 40 45 45 50 55 65 D 40 45 40 45 40 45 40 45 40 45 45 50 55 65 CDQ2B12-5S -10S CDQ2B16-5S -10S CDQ2B20-5S -10S CDQ2B25-5S -10S CDQ2B32-5S -10S CDQ2B40-5S -10S CDQ2B50-10S -20S CDQ2B12-5T -10T CDQ2B16-5T -10T CDQ2B20-5T -10T CDQ2B25-5T -10T CDQ2B32-5T -10T CDQ2B40-5T -10T CDQ2B50-10T -20T M3 X 35 l X 40 l M3 X 40 l X 45 l
If the fluid temperature is less than 5C, the moisture in the circuit could freeze, causing damage to the seals and leading to equipment malfunction. Therefore, take appropriate measures to prevent freezing. Maintenance Operating environment Warning Warning 1. Follow the procedures given in the operation manual to perform a maintenance inspection.