SMC Corporation of America
Elite Part Number Search
Search Results "S070C-5BG-32"

Bore size S B Basic style n pcs. n L Axial foot style 32 mm 32 F Rod side flange style 40 mm 40 Auto switch G Head side flange style 50 mm 50 Nil Without auto switch C Single clevis style 63 mm 63 For the applicable auto switch model, refer to the table below. D-Z7/Z80/Y59/Y69/Y7 types are shipped together, (but not assembled).

Bore size 32 to 63 M9BW MHS2 D 50 Made to Order Refer to page 545 for details. 2 fingers Number of fingers 2 Number of auto switches Nil S 2 pcs. 1 pc. Action Bore size Double acting D 32 40 50 63 32 mm 40 mm 50 mm 63 mm Auto switch Nil Without auto switch (Built-in magnet) For the applicable auto switch model, refer to the table below.

Auto Switch Internal Circuit D-F8N Mass Unit: g DC (+) Brown D-F8N Switch main circuit Switch main circuit Switch main circuit D-F8P D-F8B Auto switch model OUT Black 7 7 7 0.5 Lead wire length (m) 32 32 32 3 52 52 52 5 DC () Blue D-F8P Dimensions Unit: mm DC (+) Brown D-F8 M2.5 x 4 l Slotted set screw 4.3 OUT Black Indicator light 2 DC () Blue 4.6 10 2.8 2.7 D-F8B OUT (+) Brown 3.1 10.9

39 7.5 16 2,550 AFW1500-N30FM-WS 1,500 1/2 1/2 326 4 flg. ** 32 39.5 9.75 18.25 3,570 AFW2100-N40FM-WS 2,100 C 1/2 1/2 439 6 flg. ** 32 41 12 20.5 6,460 AFW3800-N60FM-WS 3,800 3/4 3/4 647 8 flg. ** 32 41.5 14.5 24 11,050 AFW6500-N80FM-WS 6,500 3/4 3/4 778 10 flg. ** 32 42.5 17.5 28 17,000 AFW10-N100FM-WS 10,000 CF CF CF 12 flg. ** CF CF CF CF 28,050 AFW16500-N120FM-WS 16,500 * Bottom drain

Manual override 55 40 24 2 x 8.5 (For mounting) NC 145.3 106.8 51.5 32 3R 86 48 1P NO 1/2 1(P), 3(R) port (Pitch) P = 41 37 8 L2 L1 PE port (4) Refer to page 24 separately when piping to PE port is required.

Plug Connector Lead Wire Length Connectors for Series VEX3 Body Sizes 12, 22, 32 and 42 How to Use DIN Connector Caution Caution The standard length of a plug connector with lead wire is 300 mm, but the following lengths are also available.

Binary digit (decimal value) 0 to 50 ASCII hex "00" to "32" (d) Target position (encoder count value): This item is valid in Pulse Input Type control signal mode only. The target position data is sent as an encoder count value. Count value 1,000,000 has been fixed for 0 mm as a reference point.

One SI unit can be connected with manifold valves with up to 32 outputs and the input output I/O units with maximum 10 units. SI unit: Performs Fieldbus communication and solenoid valve manifold ON/OFF output. Digital input unit: For connecting sensors with switch output capability. PNP and NPN types are available.

-3No.EX-OMN0029CN-D / 1 1.5 *3) *3)1 1 -4No.EX-OMN0029CN-D () () () () -5No.EX-OMN0029CN-D / () * UL UL1310 Class2 0V -6No.EX-OMN0029CN-D * IP67 / *() SI SI () ()SI SI * IP67 M12(M8) ( ) () -7No.EX-OMN0029CN-D CE * (20 ) PLC PLC * -8No.EX-OMN0029CN-D SI 1 SI 32 10 (SI ) U SI D SI ON/OFF PNP NPN PNP NPN PNP NPN EX600 D -9No.EX-OMN0029CN-D AD 16 10 16 10 DIN

No.EX-OMN0027CN-D PROFIBUS DP SI // EX600-SPRA EX600-ED 2 8 9 11 13 13 15 SI 16 16 17 17 18 LED 22 24 25 26 27 29 29 31 32 42 43 52 52 63 GSD 63 63 SIEMENS PLC S7 64 67 69 70 78 -1No.EX-OMN0027CN-D [][][] (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating

Lock piston seal CBM2-20-PS CBM2-25-PS CBM2-32-PS CBM2-40-PS NBR 20 25 32 40 CBM2-20-PS CBM2-25-PS CBM2-32-PS CBM2-40-PS Cushion needle seal Set of left nos. @6, @7. With lock at double ends CBM2-20-PS-W CBM2-25-PS-W CBM2-32-PS-W CBM2-40-PS-W 20 25 32 40 CBM2-20-PS-W CBM2-25-PS-W CBM2-32-PS-W CBM2-40-PS-W Set of left nos. @6, @7. Seal kit includes @6 and @7.

How to Order CP96S B W J 32 100 C CP96SD B W J S 32 100 M9BW C With auto switch With auto switch (Built-in magnet) Number of auto switches Mounting B Basic L Axial foot F Rod ange G Head ange C Single clevis D Double clevis Bore size Nil 2 S 1 3 3 n n 32 32 mm 40 40 mm 50 50 mm 63 63 mm 80 80 mm 100 100 mm * Mounting brackets are shipped together, but not assembled.

AC40 AF40, AR40, AW40 AL40, AFM40, AFD40 AWM40, AWD40 36 36 32 AC40-06, AF40-06, AR40-06, AW40-06 AL40-06, AFM40-06, AFD40-06 E500-06 44 40 32 3/4 E600-06 E600-10 3/4 1 AC50, AC55, AC60, AC50B, AC55B, AC60B AF50, AR50, AL50, AF60, AR60, AL60 53 48 35 Notes) in model numbers indicates a thread type.

Provides high linearity and high precision. 1 Series CYP How to Order CYP 15 Z73 200 Clean rodless cylinder Cylinder bore size Number of auto switches 15 32 15mm 32mm 2 pcs. 1 pc. n pcs. Nil S n Standard stroke Standard stroke (mm) 100, 150, 200, 250, 300 350, 400, 450, 500, 600, 700 Bore size (mm) Type of auto switch 15, 32 Nil Select auto switches from the table below.

Microspeed Cylinders CJ2X/CUX/CQSX/CQ2X/CM2X (10, 16) (10 to 32) (12 to 25) (32 to 100) (20 to 40) Clean room compatible Series 10-/11Achieves stable low speed operation even at 0.5mm/s (1mm/s for 16 bore size or smaller) Minimum operating pressure reduced (Low friction characteristics improved) Series CQ2X now includes four brand-new large bore sizes: 50, 63, 80, and 100.

34 115 278 5 70 56 1 121 144 129 MXW8125 32 32 25 138 328 6 95 81 2 141 176 149 MXW8150 32 32 45 168 378 7 120 106 2 145 MXW Series Long Stroke Slide Table Dimensions MXW 12 Stroke: 50, 75 Operating port 2-M5 x 0.8 (mm) Width across hexagon socket hole 2.5 J 12 Scale: 30% 6.5 Width across flats 8 5H9 +0.03 depth 4.5 0 Operating port M5 x 0.8 Operation direction A 6-M4 x 0.7 thread depth

Subplate BLrna N AXT 335-12.2 '14 Hold Down Bolts 32 x 1 n.')

Grommet: VKF334-G-01 DIN terminal: VKF334-D-01 Base mounted type 33.5 16.7 26 4 Manual override (non-locking) A 12.7 20 10 18.5 20.5 3 32 71.5 Max. 10 2-4.3 (mounting holes) Applicable cord O.D. 4 to 6.5 48.5 Approx. 300 (lead wire length) 26 4 Pg.7 3 27 Manual override (non-locking) A 20.5 18.5 3 32 59 68 78 70.5 43.5 12 7.5 P R 13.5 11 33.5 7.5 12 43.5 P R 3-Rc(PT) 1/8 (ports P, A, R) 13.5

One SI unit can be connected with manifold valves with up to 32 outputs and the input output I/O units with maximum 10 units. SI unit: Performs Fieldbus communication and solenoid valve manifold ON/OFF output. Digital input unit: For connecting sensors with switch output capability. PNP and NPN types are available.

MI-A0802-8 MI-A1202-12 MI-A2002-20 MI-A2502-25 MI-A3202-32 MI-A0801-8 MI-A1201-12 MI-A2001-20 MI-A2501-25 MI-A3201-32 MI-A1201-12 MI-A1202-12 MI-A1203-12 MIW12-PS MIW-A1204 MI-A2001-20 MI-A2002-20 MI-A2003-20 MIW20-PS MIW-A2004 MH-G01 MH-G01 (contents quantity 30 g) MI-A2501-25 MI-A2502-25 MI-A2503-25 MIW25-PS MIW-A2504 MI-A3201-32 MI-A3202-32 MI-A3203-32 MIW32-PS MIW-A3204 Main parts No