(Port size: R3/4) OUT of filtered fluid (Port size: R1 or R2) DRAIN Port to discharge all fluid when replacing the element. (Port size: R3/4) Table 1. Description and function of parts No.
R3 3 (29) 32 ( 35) 29 5 37 (45) 5 MQR8-F MQR12-F 4-6 counter bore 5 4-3.2 through P.C.D.48 4-8 counter bore 5.5 4-4.5 through32 drill through 4-4.5 through 2-4.2 through 3 *at 2 points 27 drill through 45 25 R4 R4 45 3.5 (43) 41 5 (55) 7 45 ( 50) 46.5 4 Series MQR Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
Nil FKM 1349-80*1 N1 EPDM 2101-80*1 P1 Barrel Perfluoro 70W Q1 Kalrez 4079 R1 Chemraz SS592 R2 SS630 R3 SSE38 S1 VMQ 1232-70*1 T1 FKM for Plasma 3310-75*1 *1 Values at normal temperature, excluding gas permeation *2 Refer to Construction on page 5 for changed part. Number corresponds with the parts number on the construction drawing.
Thread size Tightening torque (Nm) NPT, R1/8 3 to 5 NPT, R1/4 8 to 12 NPT, R3/8 15 to 20 NPT, R1/2 20 to 25 NPT, R3/4 28 to 30 NPT, R1 36 to 38 NPT, R1 1/4 40 to 42 NPT, R1 1/2 48 to 50 (3) If the product is screwed in with excessive torque, a large amount of sealant will seep out.
Cooled substance total volume V Cooling time h Cooling temperature difference T Circulating fluid : 20 L : 15 min : 5C (5 K) : Clear water Density : 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kgK) T xV x x C h x 60 x 1000 Q = Cools 20 L of clear water from 30C to 25C in 15 minutes. 5 x 20 x 1 x 10 3 x 4.2 x 10 3 V = 15 x 60 x 1000 AL SI OUT = 467W PURGE OUT PURGE IN CHEMICAL POWER IN WATER
P1 70W XGT Kalrez Q1 R1 R2 R3 S1 T1 4079 SS592 SS630 SSE38 1232-70 3310-75 To order something else Nil (standard), list the symbols starting with X, followed by each symbol for "body surface treatment", "seal material" and then changed parts at last. CYV Chemraz Example) XLAQ-25-M9NA-XAN1A VMQ FKM for Plasma ULTIC ARMOR U1 UA4640 Produced by Mitsubishi Cable Industries, Ltd.
Port size : Rp1/4 Port size : R3/4 OUTLET Outlet of filtered fluid Port size:R2 Fig. 1 Description of parts and functions Table 1. Description and function of parts No Description Part number Material Function Hex.
IDF125F-W/150F-W: Water-cooled type T A B 4 x Eyebolt I.D. 25 G S Facility water outlet R3/4 (When symbol-W4 is specified.) Terminal block for power supply Ball valve Facility water outlet R3/4 (When symbol-W5 is specified.) Terminal block for signal F C Q R Y-shaped strainer 3/4 (Accessory) Drain tube Facility water inlet Facility water inlet L R3/4 (When symbol-W4 is specified.)
. + 4 x (n pcs. 1) 36 0.3 36 0.3 4 x R3 or less 4 x R3 or less 67 or more Panel thickness 1 to 5 mm Note) This is the minimum value for the piping method 01 or N01. Take the piping material and tubing into account for design.
(mm) Applicable cylinder bore size (mm) 4 6 8 10 12 ASG22F-M5 ASG32F-01 ASG42F-02 ASG52F-03 ASG62F-04 M5 x 0.8 6, 10, 16, 20 R1/8 20, 25, 32 R1/4 20, 25, 32, 40 R3/8 40, 50, 63 R1/2 63, 80, 100 Specifications Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1 MPa Min. operating pressure 0.1 MPa Ambient and fluid temperature 5 to 60C (No freezing) Number of needle rotations 10 turns
Nil With R3 3 RB 15 N Without (Roller specification) R5 5 RC 20 Applicable Stroke Table Stroke Size 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 25 32 40 Controller Nil Without controller CH With controller C 5 H 7 T (Communication protocal Interface Communication plug connector I/O cable*2 /Input/Output) Symbol Type Applicable interface 5 Parallel inputNPN) Nil Without
Given an ambient temperature of 30C and a relative humidity of 60%. Trace the arrow mark, from point A of ambient temperature 30C to obtain the intersection B on the curved line for the relative humidity of 60%. Trace the arrow mark, from the intersection B to obtain the intersection D on the curved line for the 0.7 MPa pressure characterisitics.
PFM7S-(N)01L/(N)02L/F01L 2 17 -62No.PF-OMJ0005CN-I PFM7-F02 21 2 -63No.PF-OMJ0005CN-I PFM7-F02L 2 21 -64No.PF-OMJ0005CN-I PFM7S-F02 21 2 -65No.PF-OMJ0005CN-I PFM7S-F02L 2 21 -66No.PF-OMJ0005CN-I PFM7-C4/C6/C8/N7 2 -67No.PF-OMJ0005CN-I PFM7-C4L/C6L/C8L/N7L 2 -68No.PF-OMJ0005CN-I PFM7S-C4/C6/C8/N7 2 -69No.PF-OMJ0005CN-I PFM7S-C4L/C6L/C8L/N7L 2 -70No.PF-OMJ0005CN-I A 54 +0.5 0 74 +0.5 0 1 2R R3
Actuator cable type/length Stroke [mm] Robotic cable [m] Stroke Note Nil None R8 87 Size Applicable stroke R1 1.5 RA 107 50 500 16 50,100,150,200,250,300,350,400, R3 3 RB 157 450,500 R5 5 RC 207 50 800 25 50,100,150,200,250,300,350,400, 450,500,550,600,650,700,750,800 Controller 50,100,150,200,250,300,350,400, 450,500,550,600,650,700,750,800, 850,900,950,1000 50 1000 32 Nil Without controller
Pressure Gauge + Lubricator Regulator with Built-in Pressure Gauge with Back Flow Mechanism ACG20A/30A/40A P .7 ARG20K/30K/40K P .24 Air Filter + Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge ACG20B/30B/40B P .9 Filter Regulator with Built-in Pressure Gauge Air Filter + Mist Separator + Regulator with Built-in Pressure Gauge AWG20/30/40 P .31 ACG20C/30C
/8 R1/2 R3/4 R1 Drain Connection (Outside Diameter of Tubing) 10mm Color Panel: Urbanwhite1Base:Urbangray2 Weight 18kg 22kg 23kg 27kg 28kg 46kg Note1: The data for m3/ (ANR) is referring to the conditions of 20C, 1atm . pressure & relative humidity of 65%.
2 4 Finger opening port 17 32 23 27.5 7 11 45 42 69 8 54 2-8.5 through 2-14 depth of counter bore 14 107 Angle adjustment bolt 3-R3 12 3-6H9 depth 8 (one each on three sides) +0.030 0 10 3-6H9 long groove depth 4 (one each on three sides) +0.030 0 M5 x 0.8 Port B M5 x 0.8 Port A 50h9 0 0.062 4-M6 x 1 Depth 10 I N J E A D P A A M N R SMC R E O P 17 P T 21.5 27.5 A I R R G Y 7 R A I 8 17.5
For single axis Actuator cable type/length Nil Without cable S1 Standard cable 1.5 m S3 Standard cable 3 m S5 Standard cable 5 m R1 Robotic cable 1.5 m R3 Robotic cable 3 m R5 Robotic cable 5 m R8 Robotic cable 8 m*1 Option Caution Nil Without option S With straight type DeviceNet communication plug for JXCD1 T With T-branch type DeviceNet communication plug for JXCD1 [CE-compliant products
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 3 8 1.0 18.2 3.0 = 15.2g/m3 20 2 3 4 1.5 15 10 5 8 7 3.0 1 6 5 0 Intake air temperature C (Atmospheric pressure) Air temperature (Pressure dew point) C -20 -10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 [Example] If air at 30C and 60% humidity is pressurized
/4 FN Rp1/4 203 203 R3/4 EB ES DRAIN R3/4 90 90 260 DRAIN FGES type (V-band type) (mm) FGEL type (V-band type) (mm) FGET type (Bolt tightening type) (mm) A A A B C B C B C Model FGESA FGESB FGESC Port size R Model FGELA FGELB FGELC Port size R Model FGETA FGETB FGETC Port size R 671 850 671 850 366 612 910 1, 2 1, 2 1, 2 554 554 931 1350 931 1325 516 871 1225 1191 1860 1191 1825 647 1133