Function: 3 (3 Position Closed Center), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 4 (3 Position Exhaust Center), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 5 (3 Position Pressure Center), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 2 (200VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: T (T-Interface), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: RWZ (R + W + Z)
Rack Mount Chiller with E.C. and Inv. P., CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 27 lb
Max Operating Pressure: 4MPa, Vessel Material, Wetted Parts: S (Stainless Steel 304), Element Length: B [ℓ500 (ℓ250 x 2)], Port Size: 06 [20 (3/4B)], Element Type: T [Fiber (Honeycomb), Polypropylene Material], Nominal Filtration Accuracy: 20 μm
Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 01 (1/8), Option: CG (C + G), Attachment: TV (T + V), Semi-Standard 1: 16C (1 + 6 + C), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: Standard, Attachment: TV (T + V), Semi-Standard 1: 6C (w/Bowl Guard, Nylon Bowl), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 1/8, Option: N.C. Float Type Auto Drain, Attachment: T + V, Semi-Standard 1: w/Bowl Guard, Nylon Bowl, Semi-Standard 2: Standard
The use of 34 pin connectors allows up to 16 stations with double solenoids.Circular connector, Tie rod base, 3000 series, IP67 protection, Number of connectors: 26 pins, Maximum number of stations: 20 (over 12 requires manifold spec. form), MFLD, PLUG-IN, CIRCULAR CONN., VALVE, SS5V3 MANIFOLD SV3000, WN, SS5V1 BUILT IN FITTING (>1/4), 1.66449 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Circular connector, Tie rod base, 3000 series, IP67 protection, Number of connectors: 26 pins, Maximum number of stations: 20 (over 12 requires manifold spec. form), MFLD, PLUG-IN, CIRCULAR CONN., VALVE, SS5V3 MANIFOLD SV3000, WN, SS5V1 BUILT IN FITTING (>1/4), 1.66449 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Circular connector, Tie rod base, 3000 series, IP67 protection, Number of connectors: 26 pins, Maximum number of stations: 20 (over 12 requires manifold spec. form), MFLD, PLUG-IN, CIRCULAR CONN., VALVE, SS5V3 MANIFOLD SV3000, WN, SS5V1 BUILT IN FITTING (>1/4), 2.20462 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Circular connector, Tie rod base, 3000 series, IP67 protection, Number of connectors: 26 pins, Maximum number of stations: 20 (over 12 requires manifold spec. form), MFLD, PLUG-IN, CIRCULAR CONN., VALVE, SS5V3 MANIFOLD SV3000, WN, SS5V1 BUILT IN FITTING (>1/4), 2.97367 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Circular connector, Tie rod base, 3000 series, IP67 protection, Number of connectors: 26 pins, Maximum number of stations: 20 (over 12 requires manifold spec. form), MFLD, PLUG-IN, CIRCULAR CONN., VALVE, SS5V3 MANIFOLD SV3000, WN, SS5V1 BUILT IN FITTING (>1/4), 2.97367 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Circular connector, Tie rod base, 3000 series, IP67 protection, Number of connectors: 26 pins, Maximum number of stations: 20 (over 12 requires manifold spec. form), MFLD, PLUG-IN, CIRCULAR CONN., VALVE, SS5V3 MANIFOLD SV3000, WN, SS5V1 BUILT IN FITTING (>1/4), 2.97367 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Circular connector, Tie rod base, 3000 series, IP67 protection, Number of connectors: 26 pins, Maximum number of stations: 20 (over 12 requires manifold spec. form), MFLD, PLUG-IN, CIRCULAR CONN., VALVE, SS5V3 MANIFOLD SV3000, WN, SS5V1 BUILT IN FITTING (>1/4), 3.41716 lb