.: Port Size: 25A, Pipe O.D.: 32mm, Output Specification: OUT1: PNP; OUT2: Analog 4 to 20mA, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
.: Port Size: 25A, Pipe O.D.: 32mm, Output Specification: OUT1: PNP; OUT2: Analog 1 to 5V, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Series: 25A-PFM7, Flow Rate Range: 25 [0.5 to 25 (12.5) L/min], Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: -
Series: 25A-PFM7, Flow Rate Range: 11 [2 to 100 (50) L/min], Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Fixed SI Unit, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: -
Series: 25A-PFM7, Flow Rate Range: 10 [0.2 to 10 (5) L/min], Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Fixed SI Unit, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: -
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Fixed SI Unit, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: -
Series: 25A-PFMB7, Flow Rate Range: 5 to 500 L/min, Thread Type: Rc, Port Size: 1/2, Out Specification: Out 1: NPN, Out 2: Analog 1 to 5 V, Lead Wire: Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber, Unit Specifications: SI Unit Only, Bracket: w/Bracket, Calibration Certificate: -
Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specifications: Unit Selection Function, Initial value psi, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -
Size/Valve Type: Size: 25A; Valve Type: N.C., Body/Port/Orifice: Body Material: Stainless Steel; Port Size: 1, Orifice Dia.: 25, Voltage/Electrical Entry: Other Voltages and Electrical Options, Other Voltages and Electrical Options: 24VAC; DIN Terminal w/Surge Voltage Suppressor, Other Options: Low Concentration Ozone Resistant, FKM Seal, Oil-free, G Thread, Bracket: -
Size/Valve Type: Size: 25A; Valve Type: N.C., Body/Port/Orifice: Body Material: C37; Port Size: 1, Orifice Dia.: 25, Voltage/Electrical Entry: Other Voltages and Electrical Options, Other Voltages and Electrical Options: 110VAC; DIN Terminal w/Surge Voltage Suppressor w/o DIN Connector, Other Options: Low Concentration Ozone Resistant, FKM Seal, NPT Thread, Bracket: -
Series: 25A-ZSE20, Rated Pressure Range: 0 to -101 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
ModelMin. operating pressure differential (MPa)Max. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) AC, DCEffective area (mm2)Thread1 (25A)25VXD2262-100.020.72251.51690
The MGP is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing length, thus enhancing the cylinders load bearing capacity. Conventional designed guided cylinders have a set bearing length resulting
The MGC guide cylinder is ideal for material handling applications involving stopping, lifting, and pushing. It combines the functions of a conventional linear cylinder, and a non-rotation device. Features include standard air cushions, grease nipple, and switch capability. Other features include, slide or ball bushing bearings, compact design, adjustable air cushion, and lightweight guided
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT GUIDE, ACTUATOR, MGP COMPACT GUIDE CYLINDER, FC, 12MM MGP OTHERS (COMBO), 8.70825 lb
B N.O. 1/2 G 15 With surge voltage suppressor C 110 VAC Stainless steel D 200 VAC 5 20A H C37 N.C. 3/4 20 E 230 VAC C N.O. J Stainless steel F 24 VDC 6 25A N.C. K C37 Stainless steel 1 25 G DIN terminal 24 VDC D N.O.