Compact and lightweight IR1000 width 35 mm mass 140 g IR2000 width 50 mm mass 300 g IR3000 width 66 mm mass 640 g Manifolding is possible 8 stations at the maximum Made to order specifications (Except Series IR2120, IR3000) OUT OUT OUT OUT OUT 550 Compatible with new modular connection brackets (-X120) Can be combined with AF (Air filter) and AFM (Mist separator).
75 IDU-FL211 IDU11E 375 265 75 360 320 90 IDU-FL212 IDU15E1 440 370 120 440 375 120 IDU-FL215 IDU22E 420 315 100 555 415 170 IDU-FL216 IDU37E 550 365 140 580 540 230 IDU-FL217 IDU55E 720 400 175 735 515 265 A filter set for the IDF-FL200 to 214 consists of 1 filter.
PAT. 17-5-172 33 Flow Switch Series PF, IF For Air Digital Flow Switch/Series PFA Display integral type Output specification Port size (Rc, NPT, G) Flow rate range (l/min) Separate type Display Sensor Switch output Analog output Accumulated pulse output PFA710 750 711 721 751 703H 706H 712H PFA510 550 511 521 551 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 150 to 3000 300 to 6000 6000 to
Standard Stroke Standard stroke (mm) Maximum manufacturable stroke (mm) Bore size (mm) 16 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1000 25, 40 1500 Strokes are manufacturable in 1 mm increments, up to the maximum stroke. However, add -XB10 to the end of the part number for non-standard strokes from 51 to 599.
.: VK300-82-1 Effective area (mm2) Model Max. flow capacity (/min (ANR)) Input Signal Connection R AMC310 AMC510 AMC610 AMC810 AMC910 Caution 3 8 16 55 165 330 550 300 1,000 3,000 6,000 10,000 3 4 Input signal when out of operation There is dispersion in operation start voltage (current) for the input signal. (Refer to page 1410-7.)
150, 200 50, 100, 150, 200, 250, 300 50, 100, 150, 200, 250, 300, 350, 400 Model MXY6 MXY8 MXY12 Model MXY6 MXY8 MXY12 X39 Fluororubber seal X42 Anti-corrosive guide unit X45 EPDM seal Mass (g) Stroke (mm) Stroke (mm) One side centralized piping, with switch rail One side centralized piping, without switch rail Model 250 300 350 400 250 300 350 400 50 230 410 910 100 280 480 1020 150 330 550
Weight Series LEFS25 V6 Stroke [mm] 50 100 150 200 250 300 350 400 450 500 550 600 Product weight [kg] 2.06 2.20 2.34 2.50 2.62 2.75 2.90 3.05 3.18 3.30 3.46 3.60 Additional weight with lock [kg] 0.3 Series LEFS32 V7 Stroke [mm] 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 Product weight [kg] 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 5.20 5.40 5.60 5.80 6.00 6.20 6.40
) Fluid level gauge Circulating fluid outlet Rc 1/2 By-pass valve Circulating fluid return port Rc 1/2 (950) (20) (15) (820) Overflow port Rc 1/2 Ventilation air outlet Ventilation air inlet Ventilation air outlet (Plugged) Tank drain port Rc 1/2 (30) (67) (300) (250) (54) (292) 4 x 37 (448) 4 x 13 Caster with adjuster (For anchor bolt) With casters (-A) (Option) HRG005-A (-A) Tank lid (550
T dimension) 1 2 3 4 5 1 2 3 4 1 2 3 4 340 410 480 550 620 430 530 630 730 560 650 750 850 04 (1/2B) 06 (3/4B) 08 (1B) Note) N.C. and N.O. common 30 10 (1 1/4B) 12 (1 1/2B) 16 (2B) 45 Note) The symbol Z indicates lengths other than the standard T length and adjustment range. Specify the T length in this case.
.: Open Closed 10 (4) 10 (4) 12 (6) 16 (8) 20 (8) 28 (12) 32 (16) 40 (20) 48 (24) 64 (32) Open Height (mm) Mass (g) Bore size (mm) 16 20 25 32 40 50 63 80 100 125 80 43.5 135 46 180 49 370 58 550 64 Closed 930 77.5 Gripping of different diameter workpieces 1,550 89 2,850 116 5,500 135 11,300 175 Standard inside ( )/MHS3 stroke MHS3 Variations MHZ Bore size (mm) With dust cover/MHSJ3 16 20
Standard Stroke Standard stroke (mm) Maximum manufacturable stroke (mm) Bore size (mm) 16 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1000 25, 40 1500 Strokes are manufacturable in 1 mm increments, up to the maximum stroke. However, add -XB10 to the end of the part number for non-standard strokes from 51 to 599.
Maximum Clamping Moment Max. clamping force Bore size (mm) 0.8 MPa 0.7 MPa 0.6 MPa 0.5 MPa 0.4 MPa 0.3 MPa Nm Ibfin Nm Ibfin Nm Ibfin Nm Ibfin Nm Ibfin Nm Ibfin For Asia For North America For Europe For France Special 40 194 1717 178 1575 154 1363 118 1044 76 673 35 310 50 250 2212 220 1947 190 1681 160 1416 130 1150 100 885 63 550 4867 500 4425 450 3982 400 3540 350 3097 300 2655 80 1360
Upper limit of allowable value Solenoid valve for locking mounted on the unlocking port Maximum value of stopping position dispersion from 100 measurements Spring Lock Holding Power (Maximum Static Load) 32 40 50 63 80 100 Bore size (mm) 552 {56} 882 {90} 1370 {140} 2160 {220} 3430 {350} 5390 {550} Holding power N {kgf} 2 Series MNB Bracket Part Numbers Rod Boot 32 40 50 63 MNB-L 80 100
GB 4.1 TECHNICAL FEATURES OF DRYERS SERIES PDE 3 20 -S MODEL PDE3-S PDE5-S PDE8-S PDE10-S PDE15-S PDE20-S Flow rate at 35C 7 bar [l/min] 350 550 850 1100 1800 2300 [m/h] 21 33 51 66 108 138 [Scfm] 12 19 30 39 64 81 Dew point* +37.8F (+3C) equal to 0.73 gr/Nm di H2O Ambient temperature nom (max) [F/C] +100 (+115) / +37.8 (+45) Min. ambient temperature [F/C] +34 / +1 Nom (max) inlet air temperature
SET SET MENU ESC DEL 1 MOVE+MOVE/// // MOVE+1 MOVE-1 x(-1 JOG+JOG/// // / JOG+ JOG09 -12.3123AZ 11ABC1 1 2 A 3 B 4 C 5 a 6 7 8 1( : ) 2SMC7STU2 S 10 - 1 5MNO2 M 1 1ABC4 C SET 1.2 1 LECP LECA LECPA TB Ver2.1* 3m IP64 CEUL 350g 550 90%RH ) -1060 90%RH ) 11 - 2.
Body size 2 AMC220 AMC310, 320 AMC510, 520 AMC610 AMC810 AMC910 Refer to page 5-10-14 for Specific Product Precautions. 3 5 6 8 9 Model/Male Thread Type Model Specifications Effective area (mm2) AMC310 AMC510 AMC610 AMC810 AMC910 16 55 165 330 550 Max. air flow (l/min(ANR)) Port size Weight (kg) Element model no.
with M5 thread Flow direction: Right to left With element service indicator Size 1/8 1/4 3/8 1/2 3/4 1 1 1/2 2 01 02 03 04 06 10 14 20 2B, 150 4B, 250 8B, 350 11B, 450 22B, 550 37B, 650 75B, 850 Rc NPT G 1/8 1/4 3/8 1/2 3/4 1 1 1/2 Nil J M R T Nil B C D Option Accessory Size Bore size RT T R JR JRT MR J MRT JT MT M 03 06 04 01 02 20 14 Size 10 2B, 150 4B, 250 8B, 350 11B, 450 22B, 550 37B
Pin description 2-Port size 44.5 40 30 1 DC(+) 50 2 OUT2 3 DC() 4 OUT1 (42.2) 73 Flow direction 6 Series PF2A Dimensions: Remote Type Sensor Unit for Air PF2A510, 550 Internal circuits and wiring examples 98 to are the terminal numbers.
Nil Without cable H Without cable (Connector only) 1 1.5 Applicable Stroke Table : Standard Stroke [mm] Manufacturable 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 stroke range Model [mm] LEFS25 50 to 600 LEFS32 50 to 800 LEFS40 150 to 1000 * When the driver type is selected, the cable is included. Select cable type and cable length.
Standard Stroke Maximum stroke available (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.