Series: LEFB (Belt Drive), Size: 32, Motor Mounting Position: Top Mounting Type, AC Servo Motor: S3 (200W Output, Incremental Encoder), Lead: S, Stroke: 400mm, Motor Option: B (Lock), Auto Switch Compatibility: None, Positioning Hole: Housing B, Bottom, Cable: S (Standard Cable), Cable Length: 5 (5m), Driver: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Connector: H (w/Connector
Series: LEFB (Belt Drive), Size: 25, Motor Mounting Position: Top Mounting Type, AC Servo Motor: S2 (100W Ouput, Incremental Encoder), Lead: S, Stroke: 300mm, Motor Option: B (Lock), Auto Switch Compatibility: None, Positioning Hole: Housing B, Bottom, Cable: S (Standard Cable), Cable Length: 2 (2m), Driver: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Connector: H (w/Connector)
Series: LEFB (Belt Drive), Size: 25, Motor Mounting Position: U (Bottom Mounting Type), AC Servo Motor: S2 (100W Ouput, Incremental Encoder), Lead: S, Stroke: 400mm, Motor Option: None, Auto Switch Compatibility: None, Positioning Hole: Housing B, Bottom, Cable: S (Standard Cable), Cable Length: 2 (2m), Driver: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Connector: H (w/Connector
Series: LEFB (Belt Drive), Size: 25, Motor Mounting Position: Top Mounting Type, AC Servo Motor: S2 (100W Ouput, Incremental Encoder), Lead: S, Stroke: 1500mm, Motor Option: None, Auto Switch Compatibility: C (with, Includes 1 Mounting Bracket), Positioning Hole: Housing B, Bottom, Cable: S (Standard Cable), Cable Length: 2 (2m), Driver: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input),
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8), Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)
3 0 0 1 SUP OUT 2 3%F.S. 3 R B(P36203018) G 2 3 RcF N IR3000G43-2-01 G43-P2-N01-X30 IR3010G43-4-01 G43-P4-N01-X30 IR3020G43-10-01 G43-P10-N01-X30 02:1/4 03:3/8 04:1/2 Rc FG NNPT 00.010.2MPa 10.010.4MPa 20.010.8MPa PRECI SI O N REG U LATO R I R302BG No.
Port size R 1/8 R 1/4 R 1/8 R 1/4 R 3/8 R 1/2 R 1/8 R 1/4 R 1/8 R 1/4 R 3/8 R 1/2 KK3P-01MS -02MS KK4P-01MS -02MS -03MS -04MS KKH3S-01MS -02MS KKH4S-01MS -02MS -03MS -04MS 1/8 1/8 1/4 1/4 Female thread type Female thread type Body size Port size Part no.
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)], Operation Manual: K (Operation
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: K
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: V (Panel Mount Adapter
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: V (Panel Mount Adapter for w/Flow Adjustment
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter), Operation Manual: Y (w/o Operation Manual, w/o Calibration