SMC Corporation of America
Elite Part Number Search
Search Results "S070C-RBC-32-X50"

One SI unit can be connected with manifold valves with up to 32 output s and the input output I/O units with maximum 10 units. Name Function SI unit Performs fieldbus communication and solenoid valve manifold ON/OFF output. Digital input unit For connecting sensors with switch output capability. PNP and NPN types are available.

(Refer to the "List of output modes" on page 32) Normal output O Operation light A light that turns on when the switch output is ON. Operation mode Either hysteresis mode or window comparator mode can be selected. The operation principle of the switch output. Normal output and reverse output can be selected. Please refer to the" List of output modes" on page 32 operating conditions.

to 47 Temperature measured value With sign: 16 bit 48 to 63 Flow measured value With sign: 16 bit 64 to 79 Accumulated flow rate lower limit Without sign: 32 bit 80 to 95 Accumulated flow rate upper limit Without sign: 32 bit Bit offset 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 Item Accumulated flow rate upper limit (PD) Bit offset 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 Item

Function selection mode 32 Default setting 32 F 1 Setting of OUT1 34 F 2 Setting of OUT2 39 F 3 Digital filter setting 42 F10 Sub display setting 43 F14 Zero cut-off setting 48 F20 External input setting 49 F30 Accumulated flow value hold setting 50 F80 Power saving mode 51 F81 Security code 52 F90 Setting of all functions 54 F95 Channel to channel copy function setting 56 F96 Sensor input

DI water (pure water): Electrical conductivity 1 S/cm or more (electrical resistivity 1Mcm or less) 3 (1) Ambient temperature: 32 oC, (2) Circulating fluid: Clean water, (3) Circulating fluid temperature: 20 oC, (4) Circulating fluid flow rate: Rated flow rate, (5) Power supply: 400 VAC 4 (1) Ambient temperature: 32 oC, (2) Circulating fluid: Clean water, (3) Circulating fluid flow rate:

N/A 1 OUT ALARM01 to 32 N/A Allows the selection either TEMP READY or AUTO PURGE signal.(Output for pin No. 8 of Chapter 8 8.1.6Communication specification Table 8-7 Contact Signal (page 8-16). See communication specification for details.

LEHS 3 5mm/s LEHS10 LEHS20 LEHS LEHS 40 32 2.2 1.4 9 7 36 52 3.9 2.5 15.5 12 63 91 [N] 5.5 3.5 22 17 90 130 *LEHS10 30%F.S.LEHS20 25%F.S.LEHS3240 20%F.S.

62 . 23 63 . 24 . 25 7CN3: . 26 8CN1:IF CONT . 27 81 . 27 82 . 29 9CN2:TB/PC . 30 91 . 30 10LED . 31 101 LED . 31 102 IF LED . 31 11 . 32 111 . 32 112 . 32 113 . 32 114 . 34 12 . 35 121 . 35 122 IF IN Data . 39 123 IN Data . 39 124 OUT Data . 41 13LEC . 42 131 LEC . 42 132 . 43 14/ . 44 15/ . 45 151 . 45 152 . 46 153 . 46 2 - 154 . 48 155 . 49 156 . 49 16/ . 50 161

Discrete Input Assembly instance ID Type Description No. of bytes Product model 17 Input 32 Discrete input Points 4 EX250-SDN1 18 Input 32 Discrete input Points 6 EX250-SDN1-X102 -25No.EX-OME0003-H The data format is shown below.

Add -XB10 to the end of standard model number. 12, 16 1 to 249 12, 16 11 to 249 Applicable stroke 20, 25, 32 1 to 399 20, 25, 32 21 to 399 mm) 40 to 100 5 to 395 40 to 100 26 to 395 Part no.: MGQM20-39 Part no.: MGQM20-39-XB10 A spacer 1 mm in width is installed in the MGQM20-40. Special body manufactured for 39 stroke. Example C dimension is 77 mm. C dimension is 76 mm. 6.

Applicable cylinder bore size (mm) Model Metric size Inch size 1 8" 3.2 4 6 8 10 12 5 32 " 3 16 " 1 4" 5 16 " 3 8" 1 2" Easy installation and removal AS1001F 6, 10, 16, 20 AS2001F 20, 25, 32 Installment of hexagon nuts on panel nuts up and down in two locations enables user to mount or remove it depending upon the situation.

Plug: KPP L A Applicable fitting size d Weight g D Model L A D d 6 32 13.8 0.4 KPP-04 4 Applicable fitting size 8 35 15.7 0.7 KPP-06 6 d 10 39 17.3 1.1 KPP-08 8 12 43 19.2 1.7 KPP-10 10 14 45.5 20.7 2.5 KPP-12 12 7 Series KPQ/KPG For Drive System Air Piping Recommended Applicable Tubing Tubing material Polyurethane: 10-series 4, 6, 8, 10, 12 Tubing O.D.

Nil S n Cylinder bore size 15 32 15mm 32mm Type of auto switch Nil Without auto switch Select auto switches from the table below.

Plug: KPP L A Applicable fitting size d Weight g D Model L A D d 6 32 13.8 0.4 KPP-04 4 Applicable fitting size 8 35 15.7 0.7 KPP-06 6 d 10 39 17.3 1.1 KPP-08 8 12 43 19.2 1.7 KPP-10 10 14 45.5 20.7 2.5 KPP-12 12 7 Series KPQ/KPG For Drive System Air Piping Recommended Applicable Tubing Tubing material Polyurethane: 10-series 4, 6, 8, 10, 12 Tubing O.D.

Color Color Page Page M Metric size (mm) Inch size (inch) Metric size (mm) Inch size (inch) 1 8 5 32 4 ( ") 5 16 8 ( ") " 3 16 " 3 8 " 1 2 " 1 4 1 8 5 32 4 ( ") 5 16 8 ( ") " 3 16 " 3 8 " 1 2 " 1 4 " (3.2) " (3.2) 6 10 12 16 6 10 12 16 General tubing 1.5 MPa max. at 20C Use in spatter generating atmosphere flame resistant material H Black Black 15-6-10 Nylon Tubing Series T White

Response Frequency 100Hz (10ms) Operating Temperature Range 0~500C (air should not be frozen) / 32~120F Temperature 25+-10 0C +-0.3% F.S. or less Characteristic* 0-500C /32~120F +-0.5% F.S. or less Repetition Accuracy +-0.2% F.S. or less Noise Resistance 500Vp-p pulse width 1s standing 1ns Withstand Voltage Between whole wires and case 1000VAC 50/60Hz for one minute Insulation Resistance

to 122F) with no condensation 5% F.S. or less 1% F.S. or less Operating pressure range Withstanding pressure Pressure loss Cumulative flow rate range Operating temperature range Linearity Repeatability 3% F.S. or less (15 to 35C [59 to 95F]) 5% F.S. or less (0 to 50C [32 to 122F]) Temperature characteristics 27: NPN open collector, 30V, 80mA, 2 outputs 67: PNP open collector, 80mA, 2

Nil S n Bore size 20 25 32 40 50 63 80 Auto switch 20 mm 25 mm 32 mm 40 mm 50 mm 63 mm 80 mm Nil Without auto switch (Built-in magnet) Thread type For the applicable auto switch model, refer to the table below. 20 25 32 40 50 63 80 M5 x 0.8 Rc NPT Nil TN Cylinder stroke (mm) Refer to Standard Stroke on page 429.

Refer to page 378 for minimum stroke with auto switch. 32 is for B-series rod size only. CH2 H B B 50 100 CH D2 H B B 50 100 M9BW With Auto Switch With auto switch (built-in magnet) Port and cushion valve positions Refer to page 359. Bore size 32 40 50 Mounting type 63 80 100 32 mm 40 mm 50 mm 63 mm 80 mm 100 mm Made to Order specifications For details, refer to page 359.

" x 0.086" 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 3/8" x 1/4" 1/4" x 5/32" 1/8" x 0.086" 3/8" x 1/4" 1/2" x 3/8" 3/8" x 1/4" 1/2" x 3/8" 3/8" x 1/4" 1/4" x 5/32" 1/8" x 0.086" 1/2" x 3/8" 3/4" x 5/8" 1/2" x 3/8" 3/4" x 5/8" 1/2" x 3/8" 3/8" x 1/4" 1/4" x 5/32" 3/4" x 5/8" 3/4" x 5/8" 1" x 7/8" 3/4" x 5/8" 1" x 7/8" 3/4" x 5/8" 1/2" x 3/8" 1" x 7/8" Port size Port