SMC Corporation of America
Elite Part Number Search
Search Results "PFM511-C8L-2-A-R"

Figure 5-67 CH1(2) Analog Output Setting Screen 1, 2 2. Use the ten-key to input a set value, and touch the [ENT] key. The CH1(2) Analog Output Setting screen 1, 2 is displayed, and the box appears flashing. Figure 5-68 Ten-key Screen [Tips] The setting has not taken effect while the box is flashing. A scaling must be specified to cause V Hi to be larger than V Lo (V Lo

S Standard cable Orange 9 B A-6 Black 8 3 Actuator side Controller side (14.2) (2) 2 1 (8) (1) B1 A1 (14) (18) (17.7) 6 5 (3) 2 1 A6 B6 15 16 L (11) (30.7) 14.2 Actuator cable [8 to 20m] (1) (2) LE-CPSignal name Terminal number Cable color Terminal number A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 8 8m * B A-2 Yellow 5 COM-A/COM B-3 Green 3 A 10m * COM-B/ A-3 Blue 4 (3) B 15m

A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 1 1.5m B A-2 Yellow 5 COM-A/COM B-3 Green 3 3 3m COM-B/ A-3 Blue 4 5 5m Shield (3) Cable color Terminal No.

13 Actuator cable type A B-5 Red 7 A A-5 Black 6 Robot cable Nil B B-6 Orange 9 B A-6 Black 8 Standard cable S 3 Electric actuator side Controller side 14.2 (2) 1 2 (8) (1) (14) 18 A1 B1 17.7 5 6 (3) 1 2 A6 B6 L 15 16 30.7 11 2 Actuator cable [8 to 20 m] (1) (2) A B-1 Brown 2 A A-1 Red 1 UCable length (L) B B-2 Orange 6 B A-2 B-3 A-3 Yellow 5 8m*1) 8 Green 3 Blue 4 10m*1) A Shield (

1600 15000 14 900 17500 1800 17500 15 1000 20 2000 20 62 No.JXC-OMU0004-A 11. 11.1 [5m ] A B-1 2 A A-1 1 LE-CP-1 L B B-2 6 1 1.5m B A-2 5 COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m Shield Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 S B B-6 9 B A-6 8 3 14.2 2 1 8 14) B1 A1 17.7 6 5 2 1 18 B6 A6 16 15 L 11 30.7 11.2 [820m] A B-1 2 A A-1 1 LE-CP-1 L B B-2 6 B A-2 5 8 8m*

A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 1 1.5m B A-2 Yellow 5 COM-A/COM B-3 Green 3 3 3m COM-B/ A-3 Blue 4 5 5m Shield Cable color Terminal no.

Do not connect the cable with the factory side at this point. 2. Turn OFF the main breaker of this system. 3. Undo the screws (2 pcs.) to remove the front panel. Be sure to use a Phillips screwdriver. 4. Undo the screws (2 pcs.) or press claw to remove the breaker cover. Be sure to use a Phillips screwdriver.

Cable color Tarminal no. 1 1.5m U 1 Red 1 V 2 White 2 3 3m W 3 Black 3 5 5m Shield signal Tarminal no. Cable color Tarminal no. 8 8m* Vcc B-1 Brown 12 GND A-1 Black 13 A 10m* A B-2 Red 7 B 15m* A A-2 Black 6 B B-3 Orange 9 C 20m* B A-3 Black 8 *produced upon receipt of order Z B-4 Yellow 11 Z A-4 Black 10 3 signal Tarminal no.

Note 2) FluorinertTM is a trademark of 3M and GALDEN is a registered trademark of Solvay Solexis, Inc. Dilute pure ethylene glycol with clear water. Additives such as antiseptics cannot be used.

B A B A B A B A B A B A B A B A B 40 50 63 80 100 6 4 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 ML2B 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 8.5 7.5 6 5 2.5 3 9 4.5 6.5 14 12.5 1.5 2 8 3.5 5.5 13 11.5 12 10 9.5 7.5 6 6.5 4.5 8 10 17.5 16 4 4.5 12.5 6 8 15.5 14 13.5 12.5 11 10 7.5 8 14 9.5 11.5 19 17.5 6.5 7 13 8.5 10.5 18 16.5 D-A9 and D-A9V cannot be mounted on 50.

Proper use of the seal cap enables the enclosure to achieve IP67 specification. -30No.EX-OMN0034-B Specification Specifications Model EX600-ED2EX600-ED3Power connector M12 (5 pin) Plug 7/8 inch (5 pin) Plug Power Power supply (Control and input) 24 VDC 10% Class2, 2 A 24 VDC 10%, 8 A Power supply (Output) 24 VDC +10/-5% Class2, 2 A 24 VDC +10/-5%, 8 A Enclosure IP67 (With manifold assembled

Note 2) D-K39A Note 2) D-M9l D-M9lW D-A9l D-B59W D-H7C D-H7BAL D-H7NF D-G5NTL D-B54 D-B64 D-C73C D-C80C A A B A B B B A B A B A B A B Bore size A 20 25 32 40 10 9 6 5 0.5 0 5.5 3.5 2.5 0 0 5.5 4.5 2 1 6.5 10 10 6 6 0.5 0.5 6.5 3.5 3.5 0 0 5.5 5.5 2 2 6.5 10 10 6 6 0.5 0.5 6.5 3.5 3.5 0 0 5.5 5.5 2 2 6.5 12 12 8 8 2.5 2.5 8.5 5.5 5.5 2 2 7.5 7.5 4 4 8.5 Note 1) Adjust the auto switch after

D-A9 30 Note 1) 15 5 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 35 + 35 (n 2) 20 + 35 D-M9V 35 20 5 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 25 + 35 (n 2) 15 + 35 D-A9V 25 15 5 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 D-M9WV D-M9AV 35 + 35 (n 2) 20 + 35 35 20 10 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 D-C7 D-C80 60 + 45 (n 2) 20 + 45 60 20 5 (n = 2, 3, 4, 5

Mount the stoppers (4) into the body B (2). (Note) The stopper has the specified position for mounting. 4. Insert the vane shaft (3) into the body A (1). 5. Tighten the body A (1) and body B (2) with the hexagon socket head cap screws (10). (Refer to table 1.) A B 6.

Memory map of input data Data (2 byte) Input area Branch connector (INPUT) MSB LSB MSB LSB 15 8 7 0 byte (b+1) byte (b) Word (a) COM A byte (b+3) byte (b+2) Word (a+1) COM B byte (b+5) byte (b+4) Word (a+2) COM C byte (b+7) byte (b+6) Word (a+3) COM D byte (b+9) byte (b+8) Word (a+4) GW unit status information byte (b+10) byte (b+11) Word (a+5) (a, b=0 to) : Only when the GW unit status

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication

The set values for OUT1 are displayed in auto-preset mode as follows: Normal output Reversed output P_1 = A-(A-B)/4 n_1 = B+(A-B)/4 A = Max. pressure H_1 = (A-B)/2 H_1 = (A-B)/2 B = Min. pressure The set values of OUT2 become as follows "_", i.e. "P_2", "n_2", "H_2".

MPa How to read the graph When a water flow of 2 l/min is generated, lP 0.017 MPa for a valve with 3 orifice (VX212, 222, 232).

Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.