SMC Corporation of America
Elite Part Number Search
Search Results "LERH10K-3L-R5"

JXCD1 JXC61 D4 Lower side R Right side parallel (4)Lead [mm] L Left side parallel Size *For size 8 8 16 25 10 12 16 (2)Motor mouting position 5 6 8 In-line D C 2.5 Right side parallel R Left side parallel L *For size 16/25 (5)Storke [mm] (7)Actuator cable type/length Robotic cable [m] (8)Controller Size #Please refer to the catalog for the controller part. 8 16 25 Without cable Nil R1 R3 R5

R1 1.5 RA 10 * R3 3 RB 15 * R5 5 RC 20 * Applicable Stroke Table *Produced upon receipt of order Stroke Size 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 Controller *Refer to catalog 16 25 32 40 Caution The actuator body and controller are sold as a package.

Temperature rises and falls +/-1 to 2 C gradually about the set point temperature. (1) Flow rate of circulating fluid is low. (2) PID parameters are wrong value. (1) Keep the flow rate 1L/min(HEC002), 3L/min(HEC006) or more. (2) If the temperature cant be stable at default value, perform auto tuning.

Description Part number Remarks Bracket A ZS-38-A1 Mounting screw (M3x5L, 2 pcs) Bracket B ZS-38-A2 Mounting screw (M3x5L, 2 pcs) Bracket C ZS-38-A3 Mounting screw (M3x5L, 2 pcs) Panel mount adapter ZS-27-C Mounting screw (M3x8L, 2 pcs) Panel mount adapter + Front protective cover ZS-27-D Mounting screw (M3x8L, 2 pcs) Front protective cover ZS-27-01 Lead wire with connector ZS-38-3L 3 cores

Panel mount adapter ZS-46-B Panel mount adapter + Front protective cover ZS-46-D Lead wire with connector ZS-46-3L 3 cores, 2 m Front protective cover ZS-27-01 R1/8 piping adapter ZS-46-N1 NPT1/8 piping adapter ZS-46-N2 One-touch fitting 4 mm straight ZS-46-C4H One-touch fitting 6 mm straight ZS-46-C6H One-touch fitting 1/4 inch straight ZS-46-N7H One-touch fitting 4 mm elbow ZS-46-C4L One-touch

(When the LER series is used, enter the part number including the rotation angle). e.g. 1) For LEY16RA-100BML, enter "LEY16RA-100". e.g. 2) For LERH30K-3L, enter "LERH30K-3".

Lead wire with connector ZS-38-3L 3 cores for 1 output, 2 m Lead wire with connector ZS-38-4L 4 cores for 2 outputs, 2 m Lead wire with connector + connector cover ZS-38-3G 3 cores for 1 output, 2 m Lead wire with connector + connector cover ZS-38-4G 4 cores for 2 outputs, 2 m Lead wire with connector for copy function ZS-38-5L 3 cores (for copy function), 1 m Lead wire with connector unit

[Tightening torque --22 to 24Nm] 3) Apply the following flow rate of radiating water. 3L/min 7Lmin When the flow rate of the radiating water is not enough, cooling capacity will decrease. Also, when the flow rate is extremely small, alarm (ERR14) may occur and the temperature of the radiating water might be extremely high.

I ':"1 6 65 274 1 7 7 1 7 7 6 52 55 -r5 loo . 6 . 202 202 6 8 65 320 227 227 6 47 75 litzs . 70 345 252 252 6 47 150 6 8 370 277 2 7 7 r 1 65 T-slot A dimensions T-slot B dimensions $unies tX$ tilo To 0[dEl' tlect|'ic Acl||at0 AC Servo Motor 100vAc TS45O1N -rslsotl I Nole 1) l Applicable Applicable TarnaFwa Sek I 2OOVAC TS45O1N AppLicable L Applicable 3 -.'

235.5 225 235.5 237.5 248 250 260.5 262.5 273 L3 L4 100 110.5 2-4-40 Body Ported Series VQ0/1000/2000 Plug Lead Unit: Flip Type VQ2000 55.5 (L plug connector) AC, Latching Manual override 50.5 (L plug connector) VQC L4 L3 49 (L plug connector) 5.2 AC, Latching L2 L1 52.5 SQ 44 (L plug connector) 48 Indicator light DIN rail clamp screw 5.5 31 VQ0 12 D-sub connector mounting screw VQ4 VQ5 R5

Construction/Dimensions (mm) R Note 2) F Note 1) PA M MD MM LA L C HB B HA W Model A CY1B 6 12 M3 x 0.5 x 3l 15 17 6.3 11 35 18 10 2.5 CY1B10 17 M3 x 0.5 x 3l 15 38 18 25 9.5 26 10 2.5 CY1B15 4 25 M3 57 25 M4 x 0.7 6.5 23 16 35 5.5 16.5 6 36 CY1B20 27 4 30 M4 x 0.7 M3 66 18 36 6.5 5.5 17 23.5 6 37 CY1B25 36 M5 x 0.8 M4 5 30 46 8.0 21 28.5 70 47 20 5.5 7 CY1B32 M5 6 47 M6 x 1.0 9.5

(When the LER series is used, enter the part number including the rotation angle). e.g. 1) For LEY16RA-100BML, enter "LEY16RA-100". e.g. 2) For LERH30K-3L, enter "LERH30K-3".

Facility water inlet A 3L-capacity or bigger drain pan is required. Facility water outlet 15cm or less Rear Drain pan Figure 7-3 Drain Pan Attachment HRW Series 7.3 Storage 7-5 HRX-OM-K003 Chapter 7 System Maintenance 2. Remove facility water piping. Remove the joints such as unions if present. 3.

.: 4.5 to 7 (Reference) 0.5 mm2 to 1.5 mm2, 2-core or 3-core, equivalent to JIS C 3306 Applicable crimped terminal O terminal: R1.25-4M that is specified in JIS C 2805 Y terminal: 1.25-3L, which is released by JST Mfg. Co., Ltd.

Internal torque control mode Position control mode Position control mode Internal speed control mode PD07 *DI3-1 Input signal device selection 3L (CN1-5) 0D06h Refer to Any input signal can be assigned to the CN1-5 pin. The devices that can be assigned and the setting method are the same as in parameter No. PD03. the name and function field. Select the input device of the CN15 pin.

Applicable crimp-style terminal 1.25Y-3L, 1.25-3.5S, 1.25-4M 7-9-39 40 Technical Data 2: How to Mount and Move the Auto Switch Mounting Bracket Band Mounting Style Caution Reed switchD-C73, D-C76, D-C80, D-C73C, D-C80C Solid state switchD-H7A1, D-H7A2, D-H7B, D-H7BAL D-H7C, D-H7NF, D-H7NW, D-H7PW, D-H7BW 1.

Bolt holder (movable) Approx. 0.5 or less 77 Dual rod cylinder/Compact type CXSJ 2122CXSJ/ 1112Dimensions / 6 10 9+ST 4-M3 x 0.5 thread depth 3.5 8 2.7 6.7 2-M3 x 0.5 thread depth 3 (Piping port) Steel ball 4.5 15 M3 x 0.5 thread depth 3.5 Vacuum suction port 24.5 25 Note) 11-, 22: Vacuum suction port 12-, 21: Relief port ST 13.4 47+ST 11 1.2 37+ST 5.5 4.5 10+ST 3.8 3.8 11 2.75 M3 x 0.5 x 3L

.: 4.5 to 7 (Reference) 0.5 mm2 to 1.5 mm2, 2-core or 3-core, equivalent to JIS C 3306 Applicable crimped terminal O terminal: R1.25-4M that is specified in JIS C 2805 Y terminal: 1.25-3L, which is released by JST Mfg. Co., Ltd. Stick terminal: Size 1.5 or shorter 49 Series VF Specific Product Precautions 3 Be sure to read before handling.

Applicable crimp-style terminal 1.25Y-3L, 1.25-3.5S, 1.25-4M 8-30-55 56 Technical Data 2: How to Mount and Move the Auto Switch Mounting Bracket Band Mounting Style Caution Reed switchD-C73, D-C76, D-C80, D-C73C, D-C80C Solid state switchD-H7A1, D-H7A2, D-H7B, D-H7BAL D-H7C, D-H7NF, D-H7NW, D-H7PW, D-H7BW 1.

Applicable crimp-style terminal 1.25Y-3L, 1.25-3.5S, 1.25-4M 8-30-55 56 Technical Data 2: How to Mount and Move the Auto Switch Mounting Bracket Band Mounting Style Caution Reed switchD-C73, D-C76, D-C80, D-C73C, D-C80C Solid state switchD-H7A1, D-H7A2, D-H7B, D-H7BAL D-H7C, D-H7NF, D-H7NW, D-H7PW, D-H7BW 1.