Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: R (External Pilot), Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: LO (L Plug w/o Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 03 (Base Mounted w/Sub-plate 3/8), Thread: N (NPT)

Function: 3 (3 Position Closed Center), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: E (Grommet Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 03 (Sub-plate Plug-in

Model: 22, Orifice Size: 3 (4.5mm), Configuration: 2 (N.O./Single Unit), Solenoid Valve Option: Brass Body, NBR Seal, Class B, Suffix: Standard, Port Size: 03 (3/8), Thread Type: N (NPT), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: DO (DIN w/o Connector), Full-wave Rectifier: R (w/Full-wave Rectifier)

Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 03 (Sub-plate Plug-in Terminal 3/8,

SMC's series VXK21/22/23, 2-port solenoid valve was designed with a Y type strainer installed inside the body to remove foreign materials mixed in fluids before they?enter the actuating part of the valve (armature), as well as preventing the flow of foreign materials?to downstream equipment.?

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Valves for both are easily replaced without changing existing piping.Compatible with a wide variety of fluids, Maximum operating pressure (MPa): 0.3~1.0, Effective area mm 2 (Cv): 1.4~9 (0.08~0.5), Orifice size (mm): 1.5, 2.2, 3, 4, Maximum system pressure: 1.0, VALVE, MEDIA, AIR PILOT, 2 PORT VALVE, 420 lb

Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VALVE, MEDIA, AIR PILOT, 2 PORT VALVE

Valves for both are easily replaced without changing existing piping.Compatible with a wide variety of fluids, Maximum operating pressure (MPa): 0.3~1.0, Effective area mm 2 (Cv): 1.4~9 (0.08~0.5), Orifice size (mm): 1.5, 2.2, 3, 4, Maximum system pressure: 1.0, VALVE, MEDIA, AIR PILOT, 2 PORT VALVE, K48, 0.41 lb

Valves for both are easily replaced without changing existing piping.Compatible with a wide variety of fluids, Maximum operating pressure (MPa): 0.3~1.0, Effective area mm 2 (Cv): 1.4~9 (0.08~0.5), Orifice size (mm): 1.5, 2.2, 3, 4, Maximum system pressure: 1.0, VALVE MEDIA AIR OPT, 2 PORT VALVE, K48, 410.00000 lb

Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX2 2-WAY MEDIA VALVE, 2A, VX2, 1.34848 lb, Port sizeOrifice size (mm?)ModelMax. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) C[dm3/(s?bar)]bCv3/8 (10A)3VXK2220-031.51.20.450.333.0640

Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX2 2-WAY MEDIA VALVE, 2A, VX2, 1.34848 lb, Port sizeOrifice size (mm?)ModelMax. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) C[dm3/(s?bar)]bCv3/8 (10A)3VXK2220-031.51.20.450.333.0640

Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VALVE, MEDIA, AIR PILOT, 2 PORT VALVE

or oil applications.New generation valve corresponding to energy-saving needs , Reduction of running cost and of temperature increase , Body material: Brass (C37), Stainless Steel , Seal material available: NBR, FKM, EPDM, PTFE, Rated voltage: 24VDC, 12VDC, VALVE, MEDIA, VALVE, VX2 2-WAY MEDIA VALVE, EA, VX2 BODY PT 1/4 NPT, 1.45985 lb

SMC has developed the VXE series energy saving type, 2 port solenoid valve?to help with environmental issues.? The PWM (Pulse Width Modulation) method was used to allow for less power consumption.? By reducing the energy consumption we have also reduced the heat produced by the coil. This series is available in three styles VXE directed operated, VXED pilot operated, and VXEZ?

SMC has developed the VXE series energy saving type, 2 port solenoid valve?to help with environmental issues.? The PWM (Pulse Width Modulation) method was used to allow for less power consumption.? By reducing the energy consumption we have also reduced the heat produced by the coil. This series is available in three styles VXE directed operated, VXED pilot operated, and VXEZ?

Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX2 2-WAY MEDIA VALVE, EA, VX2 BODY PT 1/4 NPT, 1.46566 lb, Port sizeOrifice dia. (mm?)ModelMax. operating pressure differential(MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) C[dm3/(s?bar)]bCv3/8 (10A)10VXE2260-030.03110.302.201.0560

SMC's series VXK21/22/23, 2-port solenoid valve was designed with a Y type strainer installed inside the body to remove foreign materials mixed in fluids before they?enter the actuating part of the valve (armature), as well as preventing the flow of foreign materials?to downstream equipment.?