Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter), Operation
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C), Operation
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter),
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual:
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C), Operation
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter),
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual:
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter), Operation
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter), Operation
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire
This is a legacy product.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, .73323 lb
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?