; rubber seal -5 to 50C, VALVE, SGL SOL, PLUG-IN, VALVE, VQ5000 VALVE, SOL 5 PORT, 2E, VQ5000 BASE MT NO SIZE RATING, 2.0878 lb
; rubber seal -5 to 50C, Optional IP65 enclosure, MFLD BLOCK, S/I, VALVE, VV5Q41 NO SIZE RATING, .71500 lb
; rubber seal -5 to 50C, Optional IP65 enclosure, INDIVIDUAL EXHAUST SPACER, VALVE, VQ4000 NO SIZE RATING, .35273 lb
10% or less)20 mA or less (without load)IP65Operating: 0 to 50C, Stored: ?25 to 85C in stock (with no condensation and freezing)1000 VAC for 1 min. between external terminals and case50M or more (500 VDC Mega) between external terminals and case4.9 m/s2490 m/s2 to X,Y,Z directions 3 times for each1000 Vp-p, Pulse width: 1 ?
; rubber seal -5 to 50C, Optional IP65 enclosure, MFLD BLOCK, D-SUB, VALVE, VV5Q41 NO SIZE RATING, .68343 lb
; rubber seal -5 to 50C, Optional IP65 enclosure, MFLD BLOCK, TERMINAL, VALVE, VV5Q41 NO SIZE RATING, 1.10000 lb
; rubber seal -5 to 50C, Optional IP65 enclosure, MFLD BLOCK, TERMINAL, VALVE, VV5Q41 NO SIZE RATING, .99000 lb
; rubber seal -5 to 50C, Optional IP65 enclosure, END PLATE, U-SIDE, D-SUB, VALVE, VV5Q41 NO SIZE RATING, .70400 lb
Location where the ambient temperature is out of the following range: During transportation or storage: -15 to 50C (No water or circulating fluid in the piping.) During operation : 2 to 45C Location where condensation forms on the inside electrical parts. Location that is exposed to direct sunlight or heat radiation Location that is near heat sources and poor in ventilation.
Location where the ambient temperature is out of the following range: During transportation or storage: -15 to 50C (No water or circulating fluid in the piping.) During operation : 2 to 45C Location where condensation forms on the inside electrical parts. Location that is exposed to direct sunlight or heat radiation Location that is near heat sources and poor in ventilation.
Location where the ambient temperature is out of the following range: During transportation or storage: -15 to 50C (No water or circulating fluid in the piping.) During operation : 2 to 45C Location where condensation forms on the inside electrical parts. Location that is exposed to direct sunlight or heat radiation Location that is near heat sources and poor in ventilation.
(See Appendix 8.1.2 Communication specification on page 8-4 for details.) 11 E_OUT TEMP READY, AUTO PURGE*1 12 F.LOW TEMP 5 to 10C Issues an alarm of F.Water Low Temp WRN if the facility water falls below the set temperature. 13 F.HIGH TEMP 35 to 50C Issues an alarm of F.Water High Temp WRN if the circulating fluid exceeds the set temperature.
Enclosure IP40 Operating temperature -5 to 50C range Environmental resistance Withstand voltage 1000 VAC for 1 minute between terminals and housing 50M or more between terminals and housing Insulation resistance (with 500 VDC megger) Temperature characteristics 2% F.S.
Withstand voltage Insulation resistance Between case and AC line: 500VDC, 50M or more Ambient temperature 0 to 50C (without freezing) 35 to 85%RH (without condensation) Ambient humidity Square wave noise from a noise simulator (pulse duration 1s) between power supply terminals 2000V, I/O line 600V Noise resistance Endurance 10 to 55Hz; amplitude 0.75mm; X, Y, Z for 2 hours each Vibration
Capable No Note) Major dimensions are the same as those of the Double Acting Single Rod or Double Rod T E C H N I C A L SPECIFICATIONS SERIES (N)CQ2 LOW TEMPERATURE RESISTANT CYLINDER XB7 OPTION A C C E S S O R I E S S E R I E S N C Q 2 / C Q 2 L O W T E M P E R A T U R E R E S I S T A N T C Y L I N D E R X B 7 O P T I O N NCQ2 D XB7 Bore Size 12, 16, 20, 25, 32, 40 Fluid Air Temperature -50C
Accessory (Option)/Part Numbers 0.2 to 1.0MPa Ambient and fluid temperature 2 to 50C (No condensation) Model For VBA2200 For VBA1110-1 For VBA2100 For VBA4100 For VBA4200 Description Lubrication Not required G27-20-R12pcs. G27-10-R1-X2092pcs. G46-10-012pcs. G27-10-R1-X2092pcs. G46-10-012pcs.
Fluid Operating pressure(1) Compressed air 0.05 to 1.0MPa Proof pressure Inlet air temperature Ambient temperature Cooler Coating Installation 1.5MPa 5 to 100C 2 to 50C Aluminum plate tube w/fins Mansel N-8 (White), Mansel 2.5PB5/8.5 (Blue) Indoor Note 1) With auto drain: 0.15 to 1.0MPa Accessories (Equipped as Standard) HAA15 Drain valve Applicable Model HAA15 HAA22 HAA37 HAA7 B 3 8 B 3
IDU3D to 6D: 60C IDU8D to 37C1: 55C IDU55C, 75C: 50C Series IDF Can accommodate an inlet air temperature of 40C System efficiency is improved by using a high performance heat exchanger.
30V, 30mA PNP open collector output: Max. 30mA AMR Symbol Linearity Within 1% (full span) Hysteresis Within 0.5% (full span) AWM Repeatability Within 0.5% (full span) Sensitivity Within 0.2% (full span) AWD Temperature characteristics Within 0.12% (full span)/C 3% (full span) Accuracy ITV Output pressure display (3) MPa: 0.01, kgf/cm2: 0.01, bar: 0.01, PSI: 0.1 , kPa: 1 Minimum unit 0 to 50C
/ 32~125F 0 ~ 50C / 32~125F Lubrication Not Required Not Required Installation Horizontal Horizontal Pressure Adjustable Mechanism Relieving Type Relieving Type Handle Type Air Pilot Operated Type Type (N)VBA1110-02 (N)VBA2100-03 (N)VBA4100-04 (N)VBA2200-03 (N)VBA4200-04 Max Flow* 1000 ln/min** 1900 ln/min** 1000 ln/min** 1900 ln/min* 400 ln/min* Port Size (IN, OUT) 38 12 38 12 14 EXH Port