Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket)
Rotary Table, 11- Clean Series - Vac. 1486.00000 lb. D35.
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 10 (1), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G [Instantaneous Flow: L/min (gal/min), Temperature
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: N2 (NPT1/4), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve)
Approved by FDA; Applicable tubing O.D.: Ø 4 to Ø 12 mm; Operating temperature: -20 to 200 °C for air and 0 to 100 °C for water.
The X224 variation permits regulation between 11 and 56 psig while the X215 operates between 7 and 100 psig. Both are available in either 1/8" or 1/4" port sizes. The X224 model is available in Rc thread only, the X215 is available in Rc or NPT.
The CG1 clean series is auto switch capable.Double acting single rod; Bore sizes (mm): 20, 25, 32, 40, 50, 63, 80, 100 ; Strokes from 20mm through 300mm depending on bore size ; Mounts: basic, axial foot, rod side or head side flange ; Clean series
The CG1 clean series is auto switch capable.Double acting double rod; Bore sizes (mm): 20, 25, 32, 40, 50, 63, 80, 100 ; Strokes from 20mm through 300mm depending on bore size ; Mounts: basic, axial foot, rod side flange ; Clean series
The 11-LEFS series slider type, ball screw drive electric actuator features built-in vacuum piping along with a body-integrated linear guide specification. Available motors include step motor (servo/24VDC), servo motor (24VDC), and AC servo motor (100/200/400W).
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal,
Series: 25A-PF3W7, Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 06 (3/4), Output Specification/Temperature Sensor: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N2 (NPT1/4), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve), Calibration Certificate: None,
Rotary Table, 11- Clean Series - Vac. 310.00000 lb. D35.
Series: 25A-PFM7, Flow Rate Range: 11 [2 to 100 (50) L/min], Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: B (2 PNP Outputs), Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber)