SMC Corporation of America
Elite Part Number Search
Search Results "MS-5ATHU-4"

Bracket AF3000 1/4, 3/8 5 AF4000 1/4, 3/8, 1/2 Float style auto drain AF4000-06 3/4 Pressure differential auto-drain 3/4, 1 AF5000 AF6000 1 Mist Separator Series AFM AFM2000 1/8, 1/4 Bracket AFM3000 1/4, 3/8 0.3 Float style auto drain AFM4000 1/4, 3/8, 1/2 Pressure differential auto-drain AFM4000-06 3/4 Micro Mist Separator Series AFD AFD2000 1/8, 1/4 Bracket AFD3000 1/4, 3/8 0.01 Float style

Multi-Channel Controller Series PSE200 Pressure Sensor Series PSE530 1 A single controller monitors up to 4 pressure sensors. 2 4 MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE SET 3 1 A single controller monitors 2 4 MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE SET 3 Multi-Channel Controller Series PSE200 Pressure Sensor Series PSE530 Space saving 1 40mm MPa kPa OUT1 76% OUT2 CH 1 2 3 4 PRESSURE SET reduction

20 stations (1) VO317-(-Q) (3) Port location (Direction)/Port size A Exhaust port Symbol Type R P Base (Side) Base (Side) Base (Side) ( ) 1 4 3 8 1 Common (2) ( ) 1 4 3 8 1 4 Base (Side) Base (Side) Base (Side) 3 Individual 1 4 1 4 1 4 Note 1) For more than 3 stations, supply air both sides of P port.

40 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 HRSH250--20 50 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 M5 A HRSH100--40 20 A 3 x 5.5 mm2 (3 x AWG10) (Power supply) 1 x 14 mm2 (1 x AWG6) (Grounding cable) R5.5-5 (Power supply) R14-5 (Grounding cable) HRSH150--40 HRSH200--40 HRSH250--40 3-phase 380 to 415 VAC (50/60 Hz) 30 A Note) An example

From the state described in step w, turn back the adjusting needle clockwise 1/4 turn to 1 full turn.

Note 4) 1 3 ME = FE L1 (Nm) 1 3 Note 4) Average load coefficient (= ): This coefficient is for averaging the Dynamic moment according to service life calculations. 3.

4 !2 !5 t @0 @3 @4 @5 !9 !8 @1 @2 @6 !4 !2 !3 y !0 !1 e q @8!6 u !7 o i !3 y !0 !1 @7 r q @8 !6 u !7 o i CXSJM10 CXSJL10 @9 !7 o i !6 r !9 !8 @2 @9 !7 o i !6 @4 @5 !8 r !9 @2 Piston rod B-side piston Rod cover Piston rod B-side piston Rod cover Parts List: Standard Piping No. Description Material No.

Table 1: Model, Fitting size, Orifice Solenoid valve model (fitting size) Orifice symbol (diameter) 1 (2) 4 (6) 3 (4.5) 2 (3) XSA1 XSA2 XSA3 2(1/4) 2(1/4) 2(1/4) 3(3/8) Table 3: Spacer part nos. Table 2: Voltage, Electrical entry, Electrical options Electrical entry D, T Model Part No.

LEC-CGD LEC-CGD N.C. 1 N.C. 2 1 1 1 1 SD+ 3 2 2 2 2 SD4 3 3 3 3 N.C. 5 4 4 4 4 N.C. 6 N.C. 7 1 2 3 4 1 2 3 4 N.C. 8 LEC CN4 LEC CN4 No. No.

13-4 5 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 Standard Specifications Direct operated type 2 position single solenoid Air Max. 50C Type of actuation Fluid Ambient and fluid temperature Response time (at 0.5 MPa) Manual override(1) Valve specifications Electricity specifications 10 ms or less (Standard), 15 ms or less (Low power consumption type) Non-locking push type Not

Soft nylon Polyurethane KAH23-M5 17 8.5 14 13 2.1 M5 X 0.8 M6 X 1.0 7 17.5 12.5 8.5 3.4 2.9 4 3.2 1 8 KAH23-M6 KAH23-U01 8 10 17 KAH04-M5 M5 X 0.8 M6 X 1.0 9.5 14 13 2 4 4 8 KAH04-M6 17.5 4 1 8 18.5 13.5 KAH04-U01 5 14 10 10 16 5.6 5.6 1 4 KAH04-U02 16.5 10.5 10 18.5 KAH06-M5 M5 X 0.8 M6 X 1.0 15 14 4 4 11.5 3 10 KAH06-M6 19 1 8 14.5 KAH06-U01 5 12 6 19.5 17 1 4 13 17 14 12 KAH06

N.C. 1 N.C. 2 1 1 1 1 SD+ 3 2 2 2 2 SD4 3 3 3 3 N.C. 5 4 4 4 4 N.C. 6 N.C. 7 1 2 3 4 1 2 3 4 N.C. 8 CN4 CN4 No. No.

Table 1: Model, Fitting size, Orifice Solenoid valve model (fitting size) Orifice symbol (diameter) 1 (2) 4 (6) 3 (4.5) 2 (3) XSA1 XSA2 XSA3 2(1/4) 2(1/4) 2(1/4) 3(3/8) Table 3: Spacer part nos. Table 2: Voltage, Electrical entry, Electrical options Electrical entry D, T Model Part No.

Refer to page 4-18-4.) Ambient and fluid temperature Response time (at 0.5 MPa) (1) 10 ms or less (Standard), 15 ms or less (Low power consumption type) Non-locking push type Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)

M2.5 x 0.45 x 82 4 For nozzle size 18, 20 M2.5 x 0.45 x 86 4 6 6 6 6 2 2 2 2 4 4 4 4 For nozzle size 10, 13, 15 For nozzle size 18, 20 Standard (without options) With individual spacer For nozzle size 10, 13, 15 For nozzle size 18, 20 For nozzle size 10, 13, 15 + with function plate For nozzle size 10, 13, 15 + with function plate For nozzle size 10, 13, 15 For nozzle size 18, 20 For nozzle

Circulating fluid outlet, Circulating fluid return port Rc1 NPT1 or G1 Drain port Rc1/4 NPT1/4 or G1/4 (It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product.) HRS HRS 090 HRS 090 Part no.

Fittings & Tubing Air Cylinders Rotary Actuators Lead wire length 300 mm 1(P), 3(R) port 4-Rc1/8 Indicator light 7 2-4.5 (Mounting hole) 57 5.3 5.3 50.5 52 0.6 P 1 R 3 4 4 4 4 4 R 3 P 1 30 17 6.5 15 2 2 2 2 2 8 0.5 0.5 P=11 10 M5: M5 thread 2n-M5 4(A), 2(B) port 4 L2 35 L1 38 42 M plug connector (M) Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches

Model Option 10-/21-AW20(K)-B 10-/21-AW30(K)-B 10-/21-AW40(K)-B 10-/21-AW40(K)-06-B 10-/21-AW60(K)-B Bracket assembly Note 1) AW23P-270AS AR33P-270AS AR43P-270AS AW62P-270AS Set nut Note 2) AR23P-260S AR33P-260S AR43P-260S 10: G49-10-01, 21: G49-10-01-MS-X3 Round type Note 3) Pressure gauge Note 4) Standard 10: G49-4-01, 21: G49-4-01-MS-X3 0.02 to 0.2 MPa setting Note 1) Assembly of a bracket

Construction Symbol (B) 2 (A) 4 5 (R1) 1 (P) 3 (R2) Component Parts No.

3 3 dm 1 m 3) 0.1 d 0.5 0.5 d 1.0 1.0 d 5.0 () (mg/m 1 20,000 400 10 1 -70 1 0.01 2 400,000 6,000 100 2 -40 2 0.1 3 90,000 1,000 3 -20 3 1 4 10,000 4 +3 4 5 5 100,000 5 +7 6 +10 3.3.2 1 9 No.ZL3-OM00801-A 3.4 3.4.1 P5 (2/V) (3/E) G (1/P) 06 Rc3/4 Rc1 Rc1/8 04 Rc1/2 F06 G3/4 8() G1 G1/8 F04 G1/2 N06 NPT3/4 5/16(inch) N04 NPT1/2 NPT1 NPT1/8 3.4.2 1) 2),