Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 03 [3/8 (10,15A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.1 Solenoid, Body Option: 3 (10A), Style: 0 (Energized Open/N.C.), Option: K (Stainless Steel Body & Shading Coil, PTFE Seal, Class B Coil), Port Size: 03 [3/8 (10,15A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.1 Solenoid, Body Option: 3 (10A), Style: 0 (Energized Open/N.C.), Option: C (Brass or BC6, Copper Body & Shading Coil, PTFE Seal, Class B Coil), Port Size: 03 [3/8 (10,15A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 2 (Energized Closed/N.O.), Option: K (Stainless Steel Body & Shading Coil, PTFE Seal, Class B Coil), Port Size: 03 [3/8 (10,15A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 0 (Energized Open/N.C.), Option: Q (Stainless Steel Body & Shading Coil, PTFE (FPM) Seal, Class H Coil), Port Size: 03 [3/8 (10,15A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: G (Grommet), Surge Suppressor: None, Bracket: B (Bracket)
Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 03 [3/8 (10,15A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: S (Surge Suppressor)
Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 03 [3/8 (10,15A)], Thread: T (NPTF), Voltage: 2 (200VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: S (Surge Suppressor)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: N (Non-Relieving Exhaust Mechanism), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: N (Non-Relieving Exhaust Mechanism), Semi-Standard 2: W (Drain Cock w/Barb Fitting for ø6 x ø4 Nylon Tube)
Body Size: 40, Thread: N (NPT), Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: BD (B + D), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 03 (3/8)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: F (G)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: N (NPT)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Lead Wire: H (Grommet Lead Wire 600mm), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: N (NPT)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: K (High-pressure, 1MPa), Coil Specification: Standard, Voltage: B (24VAC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: D (Push-turn Locking Slotted Type), Port Size: 03 (3/8), Thread: F (G)
Body Size: 30, Backflow: K (w/Backflow Function), Thread: Rc, Port Size: 03 (3/8), Options: BE (B+E), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 03 [3/8 (10,15A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: S (Surge Suppressor)