Stations: 03, A,B Port: 01 (1/8), Thread: N (NPT)
Stations: 03, A,B Port: 02 (1/4), Thread: N (NPT)
Stations: 03, A,B Port: 02 (1/4), Thread: F (G)
Series: A1 (40dB(A) Noise Reduction), Port Size: 03 (3/8)
Series: B1 (38dB(A) Noise Reduction), Port Size: 03 (3/8)
Body Size: 200 (1/8 Basis), Applicable Tubing: 03 (5/32")
Body Size: 200 (1/8 Basis), Applicable Tubing: 03 (5/32")
Stations: 03, A,B Port: ø6 One-touch Fitting, Metric, Thread: -
Stations: 03, A,B Port: ø8 One-touch Fitting, Metric, Thread: -
Model: 10-SY5000, Stations: 03, A, B Port: 1/4, Thread: -
Model: 10-SY3000, Stations: 03, A, B Port: 1/8, Thread: -
Manifold Type: Base Mounted, Stations: 03, Port Size: M5 x 0.8
Size: Compact, Noise Reduction: 03 [Compact (25dB)], Port Size: 1/8
Size: Compact, Noise Reduction: 03 [Compact (25dB)], Port Size: 1/8
SS5V 03 Station Manifold, Cassette Base.
Nozzle Diameter: 15 (ø1.5mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 02 (Screw-in Rc 1/4), VAC: 03 (Screw-in Rc 3/8), EXH: 03 (Screw-in Rc 3/8), Accessories: N (w/o Bracket, w/o Silencer)
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Size: 30, Thread Type: N (NPT), Port Size: 03 (3/8), Mounting: w/o Mounting Option, Float Type Auto Drain: w/o Auto Drain, Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Drain Port: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 30, 40), Indicator: w/o Indicator, Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Z (Name Plate and