Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Rc1/8, Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
F O R M A K I N G A N D M O U N T I N G A R M S D I M E N S I O N S H E A D S I D E F L A N G E 32, 40, 50, 63 S E R I E S MK2 W H E N A R M S A R E T O B E M A D E S E P A R AT E LY, T H E I R L E N G T H A N D W E I G H T S H O U L D B E W I T H I N T H E F O L L O W I N G R A N G E.
However, the SY3000 cannot be mounted onto the SY7000 series. q Series w Connector type r Valve stations 5 7 Symbol Type Page SY5000 SY7000 Symbol Stations Note F FW P PG PH J G T L1 L2 L3 M S S6 S S S4 S3 02 IP40 IP67 26 pins 20 pins 10 pins Some connectors have a limitation on the number of stations.
P O R T S PT Ports XC18 NPT Ports (25~40 Only) A L L O W A B L E M O M E N T A N D M A X I M U M A L L O W A B L E L O A D H O W T O O R D E R M Y 1 M R O D L E S S C Y L I N D E R MY1M G M O M E N T (N M) A L L O W A B L E L O A D (N) B O R E S I Z E 16 16mm 20 20mm 25 25mm 32 32mm 40 40mm 50 50mm 63 63mm Local Production Available N O O F S W I T C H E S ...2 Pieces S ...1 Piece
fittings MI W S QB CEP1 QA Tubing O.D.
Load weight kg Load weight kg m s m s Type of impact s m 1 2 m2 Kinetic energy E1 Thrust energy E2 Fs Fs + mgs Fs mgs Absorbed energy E E1 + E2 Symbols : Speed of impacting object (m/s) m: Mass of impacting object (kg) F: Cylinder thrust (N) g: Gravitational acceleration (9.8 m/s2) s: Shock absorber stroke (m) Note) The speed of the impacting object is measured at the time of impact
Connect the driver power output (U/V/W) to the servo motor power input (U/V/W) directly. Do not let a magnetic contactor, etc. intervene. Otherwise, it may cause a malfunction. CAUTION Driver Driver Servo amplifier Servo motor Servo amplifier Servo motor U U U U V V M V M V W W W W 3 2 3.
LV E S Y M B O L S (N)VM1000 R O L L E R L E V E R D I M E N S I O N S (N)VM1000 O N E W AY T R I P D I M E N S I O N S (N)VM1000 T O G G L E D I M E N S I O N S (N)VM1000 P U S H B U T T O N PT= Pre-travel OT= Over travel TT= Total travel S Y M B O L S (N)VM1000 T O G G L E S Y M B O L S (N)VM1000 P U S H B U T T O N S Y M B O L S (N)VM1000 O N E W AY Courtesy of Steven Engineering, Inc.
1 1 C G LJ1 10 S W X10 Guide type Slider guide S X10 Non-standard motor Series Series 10 Series 20 Series 30 Limit switch 10 20 30 Nil W None B contact specification 2 pcs.
1 1 C G LJ1 10 S W X10 Guide type Slider guide S X10 Non-standard motor Series Series 10 Series 20 Series 30 Limit switch 10 20 30 Nil W None B contact specification 2 pcs.
Note 2) W V L B + Stroke M H thread depth C A + Stroke EH S Note 1) Range within which the rod can move.
(g) Note 2) W = 13n + m + 36 W = 41.2n + m + 77.6 W = 65.4n + m + 128.2 SV (n: Number of SUP/EXH blocks, m: Mass of DIN rail) Note 1) In cases such as those where many valves are operated simultaneously, use station B (SUP/EXH block on both sides), applying pressure to the P ports on both sides and exhausting from the R ports on both sides.
Rush speed into cushion is as follows: M + m 2 = 1.4a Ek = 2 Ek: Kinetic energy (J) M: Weight for the driven object (kg) m: Weight for movable part of cylinder (kg) : Maximum speed (m/s) a: Average speed (m/s) = 1.4 x 300 = 420 mm/s. Note) Set a so that rush speed into cushion should not exceed 0.75 m/s.
1 A Q a q 0 0 1 0 2 STX DC2 2 B R b r 0 0 1 1 3 ETX DC3 # 3 C S c s 0 1 0 0 4 $ 4 D T d t 0 1 0 1 5 % 5 E U e u 0 1 1 0 6 & 6 F V f v 0 1 1 1 7 7 G W g w 1 0 0 0 8 ( 8 H X h x 1 0 0 1 9 ) 9 I Y i y 1 0 1 0 10 * : J Z j z 1 0 1 1 11 + ; K [ k { 1 1 0 0 12 , < L l | 1 1 0 1 13 = M ] m } 1 1 1 0 14 . > N ^ n 1 1 1 1 15 / ?
0.5 0.0 0.0 0 0.5 1 1.5 0 0.2 0.4 0.6 0.8 1 Collision speed (m/s) Collision speed (m/s) RJ1007H Absorbed Energy RJ1412H Absorbed Energy 18 12 16 Mass of impacting object m (kg) Mass of impacting object m (kg) Horizontal or upward impact 10 14 8 12 Horizontal or upward impact Downward impact 10 6 Downward impact 8 6 4 4 2 2 0 0 0 0.5 1 1.5 0 0.5 1 1.5 Collision speed (m/s) Collision speed
-01NS 08 8 KQ2H08-01NS F2 30 (Rotating angle) 10 to 32 Model A B C D E 2 F G H J K L M N P Q R S Vacuum inlet direction q Pad dia.
side Cable description M B E Motor cable Lock cable Encoder cable A Cable type S R Standard cable Robotic cable Counter axis side Cable length (L) [m] 2 5 A 2 5 10 B LE-CSM-;;: Motor cable (13.7) SSCNET III optical cable (30) L LE CSS 1 LE-CSB-;;: Lock cable Motor type (11.8) (13) Cable length S AC servo motor L K J 1 3 0.15 m 0.3 m 0.5 m 1 m 3 m L (29.6) Cable description S SSCNET III optical