SMC Corporation of America
Elite Part Number Search
Search Results "ZA1051-N15L-P1-M2"

N N P1 P2 DC reactor Connect between P1 and P2. (Connected at time of shipping.) P1 Control Circuit Power Supply Connector: CNP2 Accessory P2 Terminal name Function Function details P P C D Connect between P and D. (Connected at time of shipping.) If regeneration option is required for Model Selection, connect to this terminal.

N N P1 P2 DC reactor Connect between P1 and P2. (Connected at time of shipping.) P1 Control Circuit Power Supply Connector: CNP2 Accessory P2 Terminal name Function Function details P P C D Connect between P and D. (Connected at time of shipping.) If regeneration option is required for Model Selection, connect to this terminal.

10-/21-AR20-B30-B: Max. 3.5 10-/21-AW40-B: Max. 5 AR50-B/60-B 10212 x P1 (Port size) A BB Pressure gauge (Option) C H K IN OUT B Q AA Applicable tubing 6/4 P2 (Pressure gauge port size) R F J M D J U Bracket (Option) T N S Optional specifications Standard specifications Model Round type pressure gauge Bracket mounting size Panel mount P1 P2 A B Note 1) C D Q R S T U V W Y Z F J K AA BB H

As a guide, when W + P0a>P0A, adjust P1 to make W + P1a = P0A. W: Load (N) P0: Operating pressure (MPa) P1, P2: Reduced pressure (MPa) a: Rod side piston area (mm2) A: Head side piston area (mm2) D-X 1241 Smooth Cylinder Specific Product Precautions 2 Be sure to read before handling.

L2 L2 M2 M2 Release button dimensions X X Y Applicable tubing O.D.: 4, 6 Male Run Tee: KQ2Y-G (Gasket seal) Connection thread M Model H (Width across flats) 2 x Applicable tubing Effective area [mm2] Min. port size Release button dimensions D2 L1 L2 L3 A M Applicable tubing O.D.

Applicable bore size (mm) Round type CJ-CR004 CJ-CR006 CJ-CR010 CJ-CR016 Flat type CJ-CF004 CJ-CF006 CJ-CF010 CJ-CF016 NTJ-004 NTP-006 NTP-010 NTP-015 4 M2 x 0.4 1.6 4 4.6 4 5 6 9 M2 x 0.4 3 6 5 6 M3 x 0.5 1.8 5.5 6.4 6 6 8 11 M3 x 0.5 5 8 6 10 M4 x 0.7 2.4 7 8.1 10 8 10 13 M4 x 0.7 6 10 8 16 M5 x 0.8 3.2 8 9.2 16 10 12 15 M5 x 0.8 7 12 10 30 Pin Cylinder: Double Acting, Single Rod Series

Y g: Gravitational acceleration, a: Average speed 24 Series MY1W Maximum Allowable Moment/Maximum Load Weight Maximum allowable moment Maximum load weight (kg) m1 Maximum allowable moment (Nm) M1 Bore size (mm) Model M2 M3 m2 m3 Select the moment from within the range of operating limits shown in the graphs.

CY1H15 CY1HT32 CY1HT25 CY1H25 64 56 (Nm) 50 40 30 50 40 30 20 28 26 M1 M2 M3 M2 M3 M1 Model Model 20 CY1H20 CY1H15 16 Moment (Nm) Moment (Nm) CY1H10 CY1H25 1.5 2.5 1.5 28 26 28 13 10 10 CY1H15 CY1HT25 10 16 10 56 85 56 2 2.5 3 4 5 2 3 4 5 CY1H20 CY1HT32 13 16 13 64 96 64 CY1H10 CY1H10 1.5 1 M3 1 0.5 0.5 70 100 300 500 1000 70 100 300 500 1000 Piston speed (mm/s) Piston speed (mm/s) M1 M2

Note 3) Cable is possible to connect to either P1 or P2. Follow the topology of EtherNet/IP communication for further direction. Warnig Refer to 14. Common Precautions for wiring and cable (P.97). Use USB cable (JXC-MA1-2) when communicating with a PC. -9No. JXC-OMU0026 3.

LED LED OFF IP NS EtherNet/IP IP OFF MS EtherNet/IP LED 10Mbps P2-100 EtherNet/IP 100Mbps / P2-L/A / / / 10Mbps P1-100 EtherNet/IP 100Mbps / P1-L/A / / / -29No.JXC-OMT0001CN-C 4.4. 1 2DIN -30No.JXC-OMT0001CN-C 4.5 (1) DIN (A) (M5 4 ) (M5)X4 () (b) DIN (DIN ) DIN M5X8DIN 2 4 (:3.0[Nm]) M5X8 (M5X14)1 DIN 2 2 :3.0[Nm] DIN () A DIN B M5X14 M5X14) DIN (:

Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.

Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.

OFF 10Mbps P1-100 EtherNet/IP communication speed Orange LED is ON 100Mbps OFF Communication is not established. No data transmission. Green LED is ON Communication is established. No data transmission. P1-L/A Data transmission status Green LED is flashing Communication is established. Data transmission in progress. -29No.

pressure gauge model Digital pressure gauge Round type pressure gauge pressure gauge (with color zone) AC20-D to AC60-D Optional specifications Semi-standard specifications Applicable PC/PA bowl Metal bowl Metal bowl with level gauge model With auto drain Drain cock with barb fitting With drain guide With drain guide With drain guide AC20-D AC30-D to AC60-D Standard specifications Model P1

How to Find the Flow Rate (at air temperature of 20 ) Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) S: Effective sectional area (mm 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow

AC20-A 58.5 59.5 37.5 37.5 104.9 87.4 93.9 91.4 AC25-A 58.5 59.5 37.5 37.5 156.8 117.6 122.1 137.6 142.1 123.6 121.9 AC30-A 65 66 37.5 37.5 156.8 117.6 122.1 137.6 142.1 123.6 121.9 AC40-A 72 72 42.5 42.5 186.9 149.6 154.1 169.6 174.1 155.6 153.9 AC40-06-A 72 72 42.5 42.5 188.9 151.6 156.1 171.6 176.1 157.6 155.9 20 Standard specifications C E F G J Bracket mount Model Note) P1

80.8 42.5 80.8 228.6 227 223 259.9 227.1 242.6 247.1 AC55-B 28 44.3 27.8 54.8 42.5 80.8 42.5 80.8 242.6 241 237 273.9 241.1 256.6 261.1 AC60-B 28 44.3 27.8 54.8 42.5 80.8 42.5 80.8 242.6 241 237 273.9 241.1 256.6 261.1 Note) For the AC20-B only, the position of the pressure gauge is above the center of the piping. 23 to to Standard specifications C E Bracket mount F G Model Note) P1

Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.

How to Find the Flow Rate (at air temperature of 20C) Choke flow: when (P2 + 0.1)/(P1 + 0.1) 0.5 293 273 + t Q = 120 x S x (P1 + 0.1) x Subsonic flow: when (P2 + 0.1)/(P1 + 0.1) > 0.5 Q = 240 x S x (P1 P2)(P2 + 0.1) x 293 273 + t Q : Air flow rate [l/min (ANR)] S : Effective area (mm) P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] t : Air temperature Note) Formulas above apply