Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: N1 [EPDM (2101-80)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: N1 [EPDM (2101-80)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
, 3 Wire NPN, Horizontal, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: N1 [EPDM (2101-80)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Or None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: N1 [EPDM (2101-80)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Valve Type: Normally Closed, O-ring Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Right Flange Surface, Temperature: 5 to 150°C, with 100°C at 100VAC, 120°C at 200VAC Heater, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, Flange Size Specification: Required for XLA
Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: N1 [EPDM (2101-80)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: -, Seal Replacement: -, Flange Size Specification: Required for XLA
Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Flange Size: 25, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: M9//--(w/o Auto Switch and w/Built-in Magnet), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: FKM, Same Specs as Standard FKM, Seal Replacement
Flange Size: 25, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: FKM, Same Specs as Standard FKM, Seal Replacement: 2
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 3-Port Valve, Solenoid Type: Single, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60℃ (no heater),
This is a legacy product. Please contact us for the latest version.sales@ocaire.com