KE D AS-FG AS-FP Rz 12.5 45 AS-FM 4. Once the fitting has been tightened, backing it out to its original position often causes the sealant to become defective. Air leakage will occur. 2. Use G external threads with G internal threads. AS-D How to distinguish between G, R and NPT threads AS-T For R, NPT thread R: Without slit NPT: With slit For G thread Step 5.
AF-OMX0052-C PRODUCT NAME Air Filter MODEL / Series / Product Number AF20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AF30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AF40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AF40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D AF50-(F,N)06(F,N)10(B,C,D)(-2,6,8,J,L,R,W,Z)-D AF60-(F,N)10(B,C,D)(-2,6,8,J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2.
AL-OMX0056-A PRODUCT NAME Lubricator MODEL / Series / Product Number AL20-(F,N)01(F,N)02(B)(-2,3,6,C,R,Z)-D AL30-(F,N)02(F,N)03(B)(-2,3,6,8,R,W,Z)-D AL40-(F,N)02(F,N)04(B)(-2,3,6,8,R,W,Z)-D AL40-(F,N)06(B)(-2,3,6,8,R,W,Z)-D AL50-(F,N)06(F,N)10(B)(-2,3,6,8,R,W,Z)-D AL60-(F,N)10(B)(-2,3,6,8,R,W,Z)-D Contents Page 1. Safety Instructions 2-6 2. Application 7 3. Standard Specifications 7 4.
HS 9 Plate Cylinder with Lock Series MLU Proper auto switch mounting position Auto switch mounting height (mm) Auto switch model (mm) D-A7H D-A80H D-F7 D-F7 V D-J79 D-F7W D-F7WV D-J79W D-F7BAL D-F7BAVL D-F79F D-A7H D-80H D-F7 D-J79 D-F7W D-79W D-F7NTL D-F7F D-F7BAL D-A73C D-A80C D-J79C D-A79W D-F7LF D-P5DWL D-F7V D-F7WV D-F7BAVL D-J79C D-A79W D-A7 D-A80 D-F7NTL D-A7 D-A80 D-A73C D-A80C D-P5DWL
/M9AV Hs B A Auto Switch Proper Mounting Position [mm] Auto Switch Mounting Height [mm] D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV A B 12 (10 x 2) 10.0 2.5 16 (12 x 2) 10.0 2.5 20 (16 x 2) 9.5 6.0 25 (20 x 2) 9.5 6.5 32 (25 x 2) 9.5 8.5 40 (32 x 2) 8.5 16.5 50 (40 x 2) 8.5 23.0 63 (45 x 2) 8.5 27.5 80 (56 x 2) 8.5 41.5 100 (71 x 2) 7.5 46.5 Auto switch model Auto switch model D-M9V D-M9WV D-M9AV
Applicable bore size B (C) (D) d H NT-02 20 13 (15.0) 12.5 M8 x 1.25 5 NT-03 25, 32 17 (19.6) 16.5 M10 x 1.25 6 NT-04 40 22 (25.4) 21.0 M14 x 1.5 8 Part no.
K F 10 AW B 30 03 BG JN K F 21 AW B 30 03 BG JN Copper, fluorine and silicone-free + Low particle generation q r t y w e Filter regulator Option/Semi-standard: Select one each for a to g.
How to order L E C C G D Branch connector ii. Dimensions (5) Terminating resistor i. How to order L E C C G R ii. Dimensions 71 - 8. Reference Information 8.1 LRC Checksum Calculation Procedure (1) How to calculate the LRC checksum The checksum calculation method in Modbus ASCII mode is based on a Longitudinal Redundancy Checking (LRC) method.
Leakage voltage Particularly when using a resistor in parallel with a switching element and using a C-R element (surge voltage suppressor) to protect the switching element, take note that leakage current will flow through the resistor and C-R element, etc., creating a danger that the valve may not shut OFF.
10 One-touch Screw-in One-touch 02 03 03 Screw-in Screw-in Screw-in ZH15DA09 11 11 One-touch One-touch One-touch 09 N03 11 One-touch Screw-in One-touch N02 N03 N03 Screw-in Screw-in Screw-in ZH18DA10 12 12 One-touch One-touch One-touch 10 03 12 One-touch Screw-in One-touch 03 03 03 Screw-in Screw-in Screw-in ZH18DA11 13 13 One-touch One-touch One-touch 11 N03 13 One-touch
AF-OMX0053-B PRODUCT NAME Mist Separator MODEL / Series / Product Number AFM20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AFM30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFM40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFM40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2. Application 8 3. Standard Specifications 8 4. How to Order 9 5.
AF-OMX0054-B PRODUCT NAME Micro Mist Separator MODEL / Series / Product Number AFD20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AFD30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFD40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFD40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2. Application 8 3. Standard Specifications 8 4. How to Order 9 5.
Air operated style fluid control valve Vacuum valve Vacuum pad 2(A) 1(P) 2(A) 1(P) 2(A) 1(P) 2(A) 3(P) 3(R) 3(R) 3(R) 1(R) Atmospheric air or micro pressure for vacuum release 22 Multi-purpose Valve Series VCA Direct Operated 2 Port Solenoid Valve for Air Improved durability (Nearly twice the life of the previous series) Operating resistance of moving parts reduced for improved longevity
t Description Attachment Seal Mesh Body Sensor Material ADC NBR Stainless steel PBT PBT Flow direction PF2A711/721/751 PF2A511/521/551 Component Parts Material ADC NBR PBT Stainless steel PBT PBT No. q w e r t y Description Attachment Seal Spacer Mesh Body Sensor Flow direction Operating Unit Descriptions Connectors Connectors shown below are applicable (female contact).
7 r !3 o r !0 w u t y !2 !3 !1 q i !4 e Meter-in type Meter-in type AS ASP ASN AQ ASV AK ASS ASR ASF Component Parts: Elbow Type Component Parts: Universal Type No. Description Material Note Body A Handle Body B Needle Gasket Seat ring Lock nut U seal Cassette Seal O-ring O-ring O-ring No.
/O.D. mm Symbol Symbol Symbol 01 02 03 04 N01 N02 N03 N04 07 09 11 13 06 08 10 12 07 09 11 13 6 8 10 12 1/4" 5/16" 3/8" 1/2" R, Rc1/8 R, Rc1/4 R, Rc3/8 R, Rc1/2 NPT1/8 NPT1/4 NPT3/8 NPT1/2 50 60 65 80 85 110 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 Metric size The figures in ( ) indicate the internal diameter of the applicable hose.
type> 79.6 67.2 167.8 L 71.2 (For E type) (Lead wire length) 1.55 0.3 mm2 26.5 13.5 11.5 20.5 20.5 5 x 3/8", 1/4" (Piping ports) 33 L plug connector with cover (LL) 52-SY7240 (R) -LL02 03 L 157.6 (Lead wire length) Insulation: Red (+) Insulation: Black () 0.3 mm2 4.1 41.7 39 (78.8) Cable type (TT) 52-SY7240 (R) -TT02 03 Max.10 L 191.2 (Lead wire length) Lead wire marking No.1 (+), No.2 (
Nijverheidsstraat 20 B-2160 Wommelgem Belguim TEL: 03-355-1464 FAX: 03-355-1466 TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. ul.