Port size (P, A and B port) Rated voltage M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz R1, R2: M5 4 Option 5 6 24 VDC 12 VDC Nil None With bracket (Not assembled) 7 240 VAC, 50/60 Hz 9 Other Option F Option Part No. Description Part no.
Use a fluid with a kinematic viscosity of 50 mm2/s or less.
SY114-5GZ Blanking plate assembly SY100-77-1A R P Manifold base (5 stations) SS3Y1-S41-05-M5 SS3Y1-S41-05-M5 1 set (Type S41, 5 station manifold part number) SY100-77-1A 1 set (Blanking plate assembly part number) SY114-5GZ 4 sets (Valve) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
Specifications )haracterislica vEA130 VEA250 iupply Power 1 10/220V + 10% (50/60H2) DC24V +2V tower Consumption sOVA 29W )utput Current Range 0-0.75A 0-1A mpedance ol E/P rroportional Valve 26-36s2 (0.75AF.S.) 13-18.5() (1A F-S.)
(Turn proof structure at pressurized state) 1.17-2 AL1000 to 6000 Standard Specifications AL1000 AL2000 AL3000 AL4000 AL4000-06 AL5000 AL6000 Model 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 M5 X 0.8 Port Size Air 1.5MPa 1.0MPa Fluid Proof pressure Max. operating pressure 1/4: 30 3/8: 40 1/2: 50 130 1/4: 30 3/8: 40 50 Min.operating flow (l/min (ANR))(1) 50 190 220 4 15 130 130 130 7 25
VCA20-12-1A 41 52 30 40 4.5 6 VCA30-12-1A 48 56 36 44 5.5 7 VCA40-12-1A 50 62 38 50 5.5 7 3 Direct Operated 2 Port for Air Series VCA Dimensions Grommet: G Conduit: C Approx. 300 Approx. 280 Q F D Q F D G1/2 C R C R L IN E E Manual override A B B A 2-P Port size 2-P Port size Manual override 2 L K 2-M Thread depth 6 2-M Thread depth 6 K DIN connector: D Conduit terminal: T F F (Q) Q S 34
Example: 2000mm lead wire length 6 10 15 20 25 30 50 300mm 600mm 1000mm 1500mm 2000mm 2500mm 3000mm 5000mm Connector housing Hook For AC SY114-1LO SY100-30-1A-20 For DC SY114-5LO SY100-30-4A-20 Lead wire 2.1-2 3 Port Direct Operated Rubber Seal Series SY100 Model Weight (g) (2) Vacuum application (MPa) Effective area (mm 2) (Cv) R port P port Operating pressure range (MPa) Model Actuation
Unrestricted 300/50 m/s2 Lubrication Mounting orientation Impact/Vibration resistance Enclosure(2) Dustproof Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 V 6, 12, 24, 48 V 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz 3.5 VA/50 Hz, 3.3 VA/60 Hz 3 VA/50 Hz, 2.8 VA/60 Hz 4 W (Standard), 2 W (Low power consumption type) 4.3 W (Standard), 2.3 W (Low power consumption
Max. 1% 26-36 (1A F.S.) Max. 1% 13'18.5 (1A F.S.) lor VoltaEe Fluct. l\,lax. +10% (1A F.S.) Max. + l% against DU22-26V (14 F.S.) Currer Stability forTmp. Fluct. l\,lax. +1% @ 79'F (25'C) {1A F.S.) Max. +2% @ 79'F (25'C) (1A F.S.) vEA 250 vEA 251 vEA 252 Cperating Temp.
Please contact us for the latest version.sales@ocaire.com, MANIFOLD BLOCK ASSY, VALVE, SS5V1 MANIFOLD SV1000, 21, SS5V1 NO SIZE RATING, .08591 lb
Please contact us for the latest version.sales@ocaire.com, MANIFOLD BLOCK ASSY, VALVE, SS5V1 MANIFOLD SV1000, 21, SS5V1 NO SIZE RATING, .09086 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529) SS5V1 MANIFOLD SV1000. MFLD, BLOCK CASSETTE. VALVE. SS5V1 OTHER SIZE RATING. .11000 lb. 11.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529) SS5V1 MANIFOLD SV1000. MFLD, BLOCK CASSETTE. VALVE. SS5V1 OTHER SIZE RATING. .07920 lb. 11.
Function 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Standard type (1W) Energy saving type (0.5W) External pilot Nil Y Note 1) Seal type R Note 2) Metal seal Rubber seal 0 1 1 2 3 Stations D side U side Note1) Applicable to DC specifications. Note2) See page 35 for details on external pilot specifications.
Function 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Standard type (1W) Energy saving type (0.5W) External pilot Nil Y Note 1) Seal type R Note 2) Metal seal Rubber seal 0 1 1 2 3 Stations D side U side Note1) Applicable to DC specifications. Note2) See page 35 for details on external pilot specifications.
Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), MFLD, BLOCK, VALVE, SS5V1 MANIFOLD SV1000, U1, SS5V1 BUILT IN FITTING 1/4), .03744 lb
Hole diameter 5 9 Features 1 3 Port Direct Operated Poppet 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 How to Order Valves Electrical entry Rated voltage 100VAC 50/60 Hz 200VAC 50/60 Hz 110VAC 50/60 Hz 220VAC 50/60 Hz 24VDC 12VDC 240VAC 50/60 Hz Other DO-DIN terminal (without connector) 1 2 3 G-grommet (lead wire length: 300mm) H-grommet (lead wire length: 600mm) D-DIN type
Hole diameter 5 9 Features 1 3 Port Direct Operated Poppet 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 How to Order Valves Electrical entry Rated voltage 100VAC 50/60 Hz 200VAC 50/60 Hz 110VAC 50/60 Hz 220VAC 50/60 Hz 24VDC 12VDC 240VAC 50/60 Hz Other DO-DIN terminal (without connector) 1 2 3 G-grommet (lead wire length: 300mm) H-grommet (lead wire length: 600mm) D-DIN type