/I.D. mm 8/5 9/6 10/6.5 12/8 12.5/8.5 16/11 Symbol 01 02 03 04 06 Symbol 50 60 65 80 85 110 Symbol 04 06 08 10 12 16 Thread size R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 R, Rc 3/4 Tubing O.D. mm 4 6 8 10 12 16 Construction
Metric size Inch size Body size Port size 3 1/8 standard 06 6 07 1/4 Symbol Cylinder side 4 1/4 standard 08 8 09 5/16 01 R1/8 5 3/8 standard 10 10 11 3/8 02 R1/4 6 1/2 standard 12 12 13 1/2 03 R3/8 04 R1/2 N01 NPT1/8 N02 NPT1/4 N03 NPT3/8 N04 NPT1/2 XTO Series Applicable tubing O.D.
4 150, 200, 250, 300 3/8 1/2 25, 50, 75, 100, 125, 150, 200 100 Non-lube Double acting, Double rod (40 to 63) 20 25 32 40 50 63 80 100 1/8 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Bore size (mm) Item 20 25 32 40 50 63 80 100 Size Suction flow rate L/min (ANR) 20/25/32/40 50/63/80/100 1.5 MPa 1.0 MPa
[Outlet port: Max.] 0.9 50 40 0.8 0.4 0.7 40 30 0.6 0.3 30 0.5 20 0.4 0.2 20 0.3 [Return port] 10 0.2 0.1 10 [Return port] 0.1 0 0 0 0 0 10 20 30 40 0 10 20 30 40 Lifting height (m) Pressure (MPa) Lifting height (m) Pressure (MPa) Circulating fluid flow (l/min) Circulating fluid flow (l/min) The pump capacity of the HRZ010-W1S is same as that of the HRZ001-L1 group on page 85.
Facility water system Electrical system Facility water temperature +27F (15C) Circulating fluid temperature Conditions 50 to 95F (10 to 35C) Facility water temperature 7.9 gpm (30 L/min) 1.1 gpm (4 L/min) 10.6 gpm (40 L/min) 10.6 gpm (40 L/min) Circulating fluid rated flow 5.3 gpm (20 L/min) 2.6 gpm (10 L/min) 6.6 gpm (25 L/min) 10.6 gpm (40 L/min) Facility water required flow rate Temperature
cF , 06, a8 010 0 10 012 rv,iIljme:tersi~e 06 08 08 01 /4" Tube out&ide . Inch' size I0 1/4" 03/8' 05/16" 05/16" diameter . . 03/S' 051160 1/2" Flbw."rate tlin\~ 330 750 350 C ,oP/rolled flow . (A,MR~~N '(lmjQ' . 180 600 1100 1190 [Ereo flaw) Effettive ~IOnal 11.6 17 2.9 5.2 18.4 5.4 9.3 'ttrea mm 2 .
A to B C to D 3,000 L 30 to 3000 30 to 3150 40 to 4000 40 to 4200 L/min 6,000 L 60 to 6000 60 to 6300 40 to 4000 40 to 4200 12,000 L 120 to 12000 120 to 12600 40 to 4000 40 to 4200 PF3A7#H 3,000 L 1.1 to 105.9 1.1 to 111.2 40 to 4000 40 to 4200 cfm 6,000 L 2.2 to 211.9 2.2 to 222.4 40 to 4000 40 to 4200 12,000 L 4.0 to 424.0 4.0 to 445.0 40 to 4000 40 to 4200 : The flow ranges and relationship
to 85C Connector Ambient temperature 20 to 75C Operating Cable 40 to 80C Fixed Protection class IP67 (Only with screw tightened) 200 Allowable repeated insertion/withdrawal Cable retaining force 150 N/15 sec.
A to B C to D 1,000 L 10 to 1000 10 to 1050 40 to 4000 40 to 4200 L/min 2,000 L 20 to 2000 20 to 2100 40 to 4000 40 to 4200 PF3A7#H 1,000 L 0.4 to 35.3 0.4 to 37.1 40 to 4000 40 to 4200 cfm 2,000 L 0.8 to 70.6 0.8 to 74.2 40 to 4000 40 to 4200 : The flow ranges and relationship between the fluid and PD are shown in the figures below.
Metric Size Applicable tubing 23 04 06 08 10 12 3.2 4 6 8 10 12 AS1002Fm TMH-23J TMH-04J TMH-06J AS2002Fm AS2052Fm TMH-06 TMH-08 AS3002Fm TMH-07 TMH-10 TMH-12 AS4002Fm TMH-13 Tubing size Applicable model The applicable TMH for the AS1002Fm-02 is not available.
How to Order AMJ Metric size Applicable tubing size Metric size (Release button: Light gray) AMV Symbol Bore size Applicable model AEP B ZFC 0 02 05 Metric size ZFC05 ZFC10 ZFC20 02 23 04 06 08 2 3.2 4 6 8 HEP Made to Order B Inch size ZFC 1 05 01 Related X17 Metal case Equipment Refer to page 1115 for details.
50 PF2MC7202 30 30 42 48 58 -99No.PF-OMZ0002-A Lead wire with M8 connector (ZS-40-A) M12-M8 conversion lead wire (ZS-40-M12M8-A) -100No.PF-OMZ0002-A Revision history A: Contents revised in several places.
50 PFMC7202 30 30 42 48 58 -95No.PF-OMY0002 Lead wire with M8 connector (ZS-40-A) M12-M8 conversion lead wire (ZS-40-M12M8-A) -96No.PF-OMY0002 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer
Output unit How to Order EX510-FC 10 10.16 0.40 Cable length (L) 01 02 05 10 20 60 1 m 2 m 5 m 10 m 20 m 60 m Brown: +24 V Black: Communications + White: Communications Blue: 0 V L Note) (Reference: AWG18) Note) Branch cable length is a maximum of 20 m. Use the cable by cutting it into lengths of 20 m or shorter. w Branch connector (Unit 1 pc.)
Double acting Body Applicable option Actuator section End plate PPS Diaphragm Port size Symbol Note 1 2 3 4 Port size 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 1/2 3/4 1 Symbol 01 02 01 02 02 03 03 04 04 06 10 Body class LQ3 Stainless steel PTFE A 1 Note) Refer to Variations in the table below for valve type combinations.
ASS AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 ASR ASQ Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FG AS331FG AS421FG AS431FG
Port size N M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 Needle Valve/Flow Characteristics AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Effective area (mm2) Effective area (mm2) Effective
AK AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 VCHC Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa ASR ASQ 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FG AS331FG AS421FG
Ionizer IZG10 08 01 01 Ionizer Gun One-touch fitting Nozzle type Symbol Applicable tube O.D.