(mm) ND NC NB NA K GE GD GC GB GA EF EE ED EC EB EA Size 10 20 30 50 47.1 57.1 58.4 74.4 44.3 55.3 60.3 71.4 33.5 43 46 56 14 18 19.5 22 80 100 110 130 20 25 27 32 15.6 19.5 21.5 28 11 14 14 18 7.5 9.5 9.5 11.5 45.2 56.4 61.5 72.9 10 14 14 19 5.5 8 8 8.5 12.5 16.5 16.5 19.5 4 4 4 6 91.4 112.4 118.7 145.8 M8 x 1 M10 x 1 M10 x 1 M14 x 1.5 Dimensions other than the above are the same as standard
M1 M2 M3 m1 m2 m3 E-MY2C 16 25 16 25 16 25 5 18 16 14 4 3.5 13 35 35 30 14 10 LJ1 LJ1 7 15 13 13 6 7 E-MY2H 28 32 30 30 26 26 LG1 LG1 46 20 18 18 55 46 E-MY2HT 100 38 35 35 120 100 Maximum Load Mass LTF LTF The above values are the maximum allowable values for moment and load mass.
Weight [g] D-M9N(V) D-M9P(V) D-M9B(V) Auto switch model Caution 0.5 8 8 7 Precautions 1 14 14 13 Lead wire length (m) 3 41 41 38 Fix the auto switch with the existing screw installed on the auto switch body.
14 Mounting thread 15 38 12-3-15 16 Series MHF2 Dimensions MHF2-12D1 3H9 +0.025 0 depth 3 42 3H9 +0.030 0 depth 3 2-M4 x 0.7 thread depth 10 Mounting thread 4 58 4 40 68 M5 x 0.8 2-M4 x 0.7 thread depth 5 20 54 Finger closing port Mounting thread E 7.7 14.8 15 19 25 E 0 -0.1 20 2-3.4 through (Mounting hole) 21 1 21 1 Finger opening port M5 x 0.8 +0.1 0 2-5.5 Close: 0 E-E Open: 241 Use the
14 Mounting thread 15 38 12-3-15 16 Series MHF2 Dimensions MHF2-12D1 3H9 +0.025 0 depth 3 42 3H9 +0.030 0 depth 3 2-M4 x 0.7 thread depth 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Mounting thread 4 58 4 40 68 M5 x 0.8 2-M4 x 0.7 thread depth 5 20 54 Finger
Table 9-6 Compliance EMC Directive 2014/30/EU Machinery Directive 2006/42/EC CE Marking RoHS Directive 2011/65/EU 9.7 Compliance HRS-R Series 9-10 HRX-OM-W058 Chapter 9 Documents 9.8 Sample DoC. Sample DoC.
Documents HRL Series 8-14 HRX-OM-Y098 Chapter 8 Documents 8.9 Sample Sample Doc. HRL Series Documents 8-15 HRX-OM-Y098 Chapter 8 Documents Mfg. code Model no.
PV SV 5.16 Alarm customize function HRS Series 5-42 HRX-OM-R016 Chapter 5 Display and setting of various functions 25. Select the changing of contact input signal 1 detection from the table below with [] key or [] key, and confirm by pressing SEL. Table 5.16-14 List of set value Set value Explanation Initial value (Default setting) This alarm signal is not detected.
M5, M6 M5, M6 KAU23-M5 38 9.6 15.5 34.5 9 M5 0.8 M6 1.0 2.2 2.2 10 38.5 3.4 2.9 11 3.2 1 8 KAU23-M6 KAU23-U01 11 9.6 KAU04-M5 M5 0.8 M6 1.0 39.5 4 2.2 2.2 KAU04-M6 10 11 16 10.4 36 10.4 40 4 1 8 KAU04-U01 4.2 4.2 11 1 4 KAU04-U02 42 16 14 KAU06-M5 M5 0.8 M6 1.0 42.5 39 2.2 2.2 13 KAU06-M6 43 13 17 1 8 KAU06-U01 3 8 KAU06-U03 46 45 43.5 12.8 39.5 17 14 12.8 14 6 Uni thread 1 4 KAU06-U02 39
4-9 Mounting plate (4-M8 x 1.25) 9 15 35 Work piece mounting dimensions 92 20 138 95 10 15.5 105 135 42 This drawing shows the TSUBAKI CABLEVEYOR with left hand entry.
15 14 9 9 10 10 11 D-B59W 14 14 17 16 18 D-A9 and D-A9V cannot be mounted on 50.
Positioning driver Model Operating Conditions Plate non-rotating accuracy () Allowable plate rotation torque (T) Allowable lateral load (F) Non-rotating accuracy () Stroke 50 75 100 125 150 175 200 Load (N) Stroke 50 75 100 125 150 175 200 Torque (Nm) 42 2.87 0.09 42 2.47 40 2.17 + 42 2.38 32 2.16 24 1.98 17 1.82 F T F Refer to page 304 for deflection data. 218 11 Courtesy of Steven Engineering
Table 9-6 Compliance EMC Directive 2014/30/EU Machinery Directive 2006/42/EC CE Marking RoHS Directive 2011/65/EU HRS-R Series 9.7 Compliance 9-9 HRX-OM-X027 Chapter 9 Documents 9.8 Sample DoC. Sample DoC.
Made to Order Specifications (For details, refer to page 4-6-46.) 4-6-14 15 3 Port Solenoid Valve Rubber Seal, Body Ported/Base Mounted Series VZ300 External Pilot VZ300R JIS Symbol VZ31R Pilot valve pressure is supplied separately from the main valve pressure through the use of a separate supply port.
AKM2000-A AKM3000-A AKM4000-A AKM2000-A AC20-A, AC20A-A 40 28 11 40 11 1/8, 1/4 AC25-A AC30-A, AC30A-A AKM3000-A 53 34 14 48 13 1/8, 1/4 IN OUT B AC40-A, AC40A-ANote) AKM4000-A 1/4, 3/8 70 42 18 54 15 C Note) A pressure switch cannot be mounted on the AC40-06-A.
AC20, AC20A AC25, AC25A AC30, AC30A AC40, AC40A Note) 40 40 28 11 11 1/8, 1/4 AKM2000 1/8, 1/4 53 48 34 14 13 AKM3000 AKM4000 70 54 42 18 15 1/4, 3/8 How to Order Note) Not applicable to AC40-06.
Auto Switch Internal Circuit D-C73C Contact protection box CD-P12 Brown Choke coil LED OUT () Brown Weight Resistor Zener diode Reed switch Zener diode (g) OUT ( ) Blue D-C73C D-C80C Auto switch model Blue 14 14 0.5 Lead wire length (m) 53 53 3 D-C80C 83 83 5 Contact protection box Dimensions OUT () Brown Reed switch CD-P11 CD-P12 Lead wire with connector OUT ( ) Blue Indicator light D-C80C
Auto Switch Internal Circuit D-C73C Contact protection box CD-P12 Brown Choke coil LED OUT () Brown Weight Resistor Zener diode Reed switch Zener diode (g) OUT ( ) Blue D-C73C D-C80C Auto switch model Blue 14 14 0.5 Lead wire length (m) 53 53 3 D-C80C 83 83 5 Contact protection box Dimensions OUT () Brown Reed switch CD-P11 CD-P12 Lead wire with connector OUT ( ) Blue Indicator light D-C80C
Model *1) * A B C D E E1 F G H K L M N J P Q MGF MXS 8 MXS12 MXS16 MXS20 MXS25 MXS-BT 8 38 23 12.5 14 40.8 5 8 12 1.4 16.6 7 15.5 14.6 M8 X 1 M3 X 12 M3 X 16 MXS-BT12 45 31 18 14 40.8 6 8 12 1.4 20.5 10 15 18.5 M8 X 1 M4 X 8 M4 X 15 CY1 MXS-BT16 55 37 23.5 16 46.7 7 10 14 1.4 23 12 18.5 21 M10 X 1 M5 X 10 M5 X 18 MXS-BT20 70 47 29 23 67.3 11 12 19 12 27 13 25.5 25 M14 X 1.5 M5 X 12 M6 X 25
(31) 30 (31) 30 (31) VPA3 14 (15.5) 14 (15.5) 1/4, 3/8, 1/2 [1 (P), 5 (EA), 3 (EB) port] 50 (54.5) 50 (54.5) 4.5 (0.5) 92 (100) 3 position closed center/exhaust center/pressure center 3 4 5 VFA5 44(-P) 02 03 04 1/4, 3/8, 1/2 [4 (A), 2 (B) port] 36 (39.5) 27 (31) 14 (15.5) 20.5 (24.5) 1/8 [Pilot port: Lateral (-P)] 2 x 5.3 (2 x 6.5) (For mounting) 82 (87) 5 (6.5) 51.5 (55.5) 2B 4A 42 (45)