Description Material Note 13 14 15 16 17 18 19 No.
5.5 M6 x 1 Rc(PT) 1/8 57.5 30 14 56 41 40 5.5 M6 x 1 Rc(PT) 1/8 64.5 30 14 62 49 50 6.6 M8 x 1.25 Rc(PT) 1/4 76.5 35 19 61.5 49 60 9 M10 x 1.5 Rc(PT) 1/4 89.5 35 19 64 Refer to page 11 regarding the rod end nut which is included.
Bore size (mm) 32 40 50 63 80 100 125 l1 d2 CK S5 K1 G1 G2 EM CA H6 R1 0.2 0.6 0.2 0.6 0.2 0.6 0.2 0.6 0.2 0.6 0.2 0.6 0.5 1.5 51 11 10 6.6 38 10 21 7 18 26 31 32 8 10 11 12 6.6 41 54 10 24 9 22 28 35 36 10 11 15 12 9 50 65 12 33 11 30 32 45 45 12 12 67 15 16 9 52 14 37 11 35 40 50 50 12 15 86 18 16 11 66 18 47 12.5 40 50 60 63 14 15 18 20 11 76 96 20 55 13.5 50 60 70 71 15 19 20 25 14 94
) (Hexagon socket head plug) MY1BG MY1BG VV VV 2-M5 x 0.8 2-M5 x 0.8 (Hexagon socket head plug) (Hexagon socket head plug) (mm) A B C E GA GB H KK J LD L LL LW M MM N NC Model G JJ K NE 80 6 3.5 2 9 16 37 6.5 M5 x 0.8 3.5 80 40 30 6 M4 x 0.7 20 14 MY1B16 14 M4 x 0.7 10 27.8 100 7.5 4.5 2 12.5 17.5 46 10 M6 x 1 4.5 100 50 37 8 M5 x 0.8 25 17.5 MY1B20 12.5 M4 x 0.7 12 34 (mm) NW PC PD T VV
Dimensions 20 to 50 Reinforcing bracket Mounted in case of 301mm or longer strokes (mm) Width across flats HT Front mounting flange Bore size (mm) R Y HS HT HU B 14 108 28.5 14 30.7 20 14 108 31 14 33.2 25 14 110 34.5 14 36.5 32 HS C D 15 121 39 14 41 40 View C-C' 16 136 49.5 17 46.2 50 16 139 56.5 17 53.2 63 HU 23 165 75.5 23 62.2 80 D' C' 23 165 86 26 72.7 100 A Dimensions other than the
(mm) H I J K L C D E F U A B Z M N O P S Bore size (mm) 32 M10 x 1.5 60 4.5 14 8.5 73.5 12 16 45 20 31.5 65 14 34 5.5 9 depth 7 Rc1/8 58.5 40 M10 x 1.5 69 5 14 8.5 75.5 12 16 52 22 35 67 14 40 5.5 9 depth 7 Rc1/8 66 50 M12 x 1.75 86 7 18 11 87 15 20 64 25 41 76 19 50 6.6 11 depth 8 Rc1/4 80 63 M12 x 1.75 103 7 18 11 91 15 20 77 27 47.5 80 19 60 9 14 depth 10.5 Rc1/4 93 80 M16 x 2 132 6 22
14 14 14 14 14 Series MHK2 Wedge Cam Operation Gripper Effective Holding Force: MHKL2 Series Double Acting The holding force shown in these tables represents the holding force when all fingers and attachments are in contact with the work.
7 34 5.5 20 to 100 51 44 13 16 52 20 M8 x 1.25 69 5 14 7 40 5.5 30 to 100 57.5 49.5 15 20 64 28.5 M10 x 1.5 86 7 17 8 50 6.6 OB P Q RB S U Z Bore size (mm) 32 40 50 9 Rc 1/8 23 7 58.5 31.5 14 9 Rc 1/8 28 7 66 35 14 11 Rc 1/4 31.5 8 80 41 19 Refer to page 7-7-14 for details on rod end nut and accessories.
7 34 5.5 20 to 100 51 44 13 16 52 20 M8 x 1.25 69 5 14 7 40 5.5 30 to 100 57.5 49.5 15 20 64 28.5 M10 x 1.5 86 7 17 8 50 6.6 mm OB P Q RB S U Z Bore size (mm) 32 40 50 9 Rc 1/8 23 7 58.5 31.5 14 9 Rc 1/8 28 7 66 35 14 11 Rc 1/4 31.5 8 80 41 19 Refer to page 11 for details on rod end nut and accessories.
18 Interface cable 7 9 8 Power cable 14 Power cable b View b View a a Wiring Signal description Cable description Color Pin no.
M5 x 0.8 1(P) port M5 x 0.8 3(R) port R 3 P 1 10.7 9 M5 X 0.8 external pilot port 32 (Only external pilot type (R)) For the One-touch fittings for P/R port and silencer model no., refer to page 4-14-3.
A A1 E1 L1 MM U1 NZ L 0.2 0.4 0.2 0.4 +0.058 0 +0.058 0 +0.4 +0.2 +0.058 0 20 I-G02 Y-G02 20 8 8 IY-G02 34 8.5 16 25 M8 x 1.25 10.3 11.5 8.5 16 25 M8 x 1.25 10.3 11.5 16 21 8 8 34 +0.058 0 +0.4 +0.2 25 I-G03 Y-G03 25 10 10 IY-G03 41 10.5 20 30 M10 x 1.25 12.8 14 10.5 20 30 M10 x 1.25 12.8 14 20 25.6 10 10 41 +0.5 +0.3 0.3 0.5 0.3 0.5 0.3 0.5 +0.058 0 +0.070 0 +0.070 0 +0.058 0 32, 40 I-G04
2 5.7 7 6 12.5 4 8.5 18.6 14 1.4 2.2 M4 x 0.7 -X 2.8 M5 x 0.8 2.5 6 8 7 14 6 8 24 18 1.8 20Data 2.7 M8 x 1 12 4 12 10.5 34 26 2.2 9 22.5 10 2.7 M8 x 1 12 4 9 26 15 11 40 36 2.8 14 M12 x 1.25 17 6 12.4 33 20 13 49 41 3.4 27 10-11-15 15 Series MIW/MIS Mounting of Auto Switch When mounting an auto switch, insert the switch in the switch mounting groove on the escapement from the direction
14 1.4 2.2 M4 x 0.7 2.8 M5 x 0.8 2.5 6 8 7 14 6 8 24 18 1.8 D-X 2.7 M8 x 1 12 4 12 10.5 34 26 2.2 9 22.5 10 Individual -X 2.7 M8 x 1 12 4 15 11 40 36 2.8 9 26 14 M12 x 1.25 17 6 20 13 49 41 3.4 12.4 33 27 1429 Series MIW/MIS Auto Switch Mounting When mounting an auto switch, insert the auto switch in the switch mounting groove on the escapement from the direction as below figure.
2 5.7 7 6 12.5 14 4 8.5 18.6 1.4 2.2 M4 x 0.7 -X 2.8 M5 x 0.8 2.5 6 8 7 14 18 6 8 24 1.8 20Data 2.7 M8 x 1 10.5 12 4 12 34 26 2.2 9 22.5 10 2.7 M8 x 1 11 12 4 9 26 15 40 36 2.8 14 M12 x 1.25 13 17 6 12.4 33 20 49 41 3.4 27 10-11-15 15 Series MIW/MIS Mounting of Auto Switch When mounting an auto switch, insert the switch in the switch mounting groove on the escapement from the direction
.: Black B 1/8 1/4 10 One-touch fitting Barb fitting Applicable tubing: T0604 M5 x 0.8 Width across flats 17 Width across flats 17 Standard specifications Bracket mount Model Port size A B C D P E F G H1 H2 J K L L M (1) (1) (1) (1) ACG20 ACG30 ACG40 1/8, 1/4 126 87 36 60 28.5 41.5 43 30 24 5.5 3.2 1/4, 3/8 167 115 41 80 30 55 57 41 35 35 14 7 7 4 1/4, 3/8, 1/2 220 147 48 110 38 72.5 75
Note 14) For an actuator with lock, add the power consumption for the lock.
entry) 14.5 (14) 28.5 +0.025 0 3H9 ( ) depth 3 2 x M5 x 0.8 thread depth 9 19 5 J G F 4 +0.025 0 3H9 ( ) depth 3 Note 1) Range within which the rod can move when it returns to origin.
Refer to the p.5.3-6 for the details of contact protection box. 13 13 13 13 13 13 13 13 13 13 13 13 14 14 14 14 14 14 14 14 14 14 14 16 15 17 17 17 17 14 16 16 13 13 13 13 Note) Average value at normal temperature including hysteresis.
Compact 20 10 10 4 3 to 6 16 to 40 11 to 28 6 to 14 25 16 14 6 4 to 8 32 20 22 52 to 130 10 16 to 40 11 to 28 40 25 30 84 to 210 14 F Type (2 fingers) S Type (3 fingers) Can hold various types of workpieces with a long stroke.