Stations: 4 Stations, Option: None, One-touch Fitting: ø8 (C8) One-touch Fitting, CE Compliant: CE Compliant
Stations: 10 Stations, Option: None, One-touch Fitting: ø8 (C8) One-touch Fitting, CE Compliant: CE Compliant
Stations: 2 Stations, Option: Name Plate, External Pilot, Silencer, One-touch Fitting: N9 5/16" One-touch Fitting, CE Compliant: -
Stations: 3 Stations, Option: None, One-touch Fitting: ø8 (C8) One-touch Fitting, CE Compliant: CE Compliant
Stations: 15 Stations, Option: None, One-touch Fitting: ø8 (C8) One-touch Fitting, CE Compliant: CE Compliant
Stations: 3 Stations, Option: None, One-touch Fitting: N9 5/16" One-touch Fitting
Stations: 3 Stations, Manifold Type: Flat Ribbon Cable w/1.5m, Option: None, One-touch Fitting: N9 5/16" One-touch Fitting
Stations: 4 Stations, Manifold Type: D-sub Connector 25 Pin w/o Cable, Option: None, One-touch Fitting: N9 5/16" One-touch Fitting
Stations: 12 Stations, Manifold Type: D-sub Connector 25 Pin 1.5m, Option: None, One-touch Fitting: N9 5/16" One-touch Fitting
Allowable voltage range 10% Electric system Circuit protector17 A 15 Applicable earth leakage breaker capacity9 A 15 Rated operating current4 (50/60Hz) A 7.5/8.3 7.7/8.4 For option -T-MT : 9.8/10.6 For option -T-MT : 10.0/11.0 Rated power consumption4 (50/60Hz) kVA 0.7/0.8 0.8/0.8 For option -T-MT : 1.0/1.1 For option -T-MT : 1.0/1.1 Noise level10 (50/60Hz) dB 58/55 Dimensions11 mm W377xD500xH615
Table 3.2-1 Amount of radiation and required ventilation Required ventilation amount (m3/min) Heat Differential temp. of Differential temp. of Model radiation 3 oC between inside and 6 oC between inside and (kW) outside of installation outside of installation area area HRS400-A-46Approx.52 865 435 Installation environment specifications Sound noise: HRS400-A-46 : 71 dB(A) Front 1m, height
3core14AWG(3 core2.0mm2) Electrical system 5.4 / 6.6 2.4 / 3.0 Rated operating current (50/60Hz) 18 A For option T1 8.7 / 9.6 4.2 / 4.6 0.43 / 0.57 0.47 / 0.59 (0.49 / 0.60) (0.50 / 0.60) Rated power consumption (50/60Hz) 18 kW For option T1 (kVA) 0.65 / 0.74 0.72 / 0.78 (0.79 / 0.86) (0.84 / 0.93) Communication function Contact input / output, Serial RS-485 / RS-232C Noise level (50/60Hz) 9 dB
0.7/0.8) (0.7/0.9) (1.1/1.2) (1.1/1.3) For option -T,-MT 0.9/1.2 0.9/1.3 1.2/1.6 1.3/1.6 Rated power consumption (50/60Hz) 18 kW (0.9/1.2) (1.0/1.3) (1.3/1.6) (1.3/1.7) (kVA) 0.9/1.1 1.0/1.3 For option T1 (1.1/1.1) (1.2/1.3) 0.9/1.0 0.9/1.0 1.2/1.2 1.2/1.3 (1.0/1.2) (1.1/1.2) (1.3/1.4) (1.3/1.5) Communication function Contact input / output, Serial RS-485 / RS-232C Noise level (50/60Hz) 9 dB
ground) 15 3core12AWG(3 core3.5mm2) 4core14AWG(4 core2.0mm2) Rated operating current (50/60Hz) 16 A 9.3/ 11.8 4.4/ 4.1(For option T1) 4.9/ 4.5(For option T2) Rated power consumption (kVA) 1.9/ 2.4(1.9/ 2.5) 2.2/ 2.5 (3.1/ 2.9) (For option T1) 2.4/ 2.7 (3.6/ 3.1) (For option T2) kW (50/60Hz) 16 Communication function Contact input/ output, Serial RS-485/ RS-232C Noise level (50/60Hz) 17 dB
OFF Serial communication Slave address Sets slave address. 1 (-)1 Mo us db Communication speed Sets communication speed. 19.2 (-)1 Slave address Sets slave address. ---(1)1 Communication speed Sets communication speed. ---(9.6)1 communication BCC Sets error detection code. ---(ON)1 protocol Simple Data length Sets data length. ---(8BIT)1 Parity check Sets parity check.
Name Function 5 4 1 DA CC-Link communication line A 4 3 2 DB CC-Link communication line B 3 2 3 DG CC-Link ground line 2 1 4 SLD CC-Link shield 1 T branch type 5 FG Frame ground (4) Communication cable for controller setting To controller PC JXCW2AC Communication cable Communication cable USB cable LECW2U Controller Configuration Software USB driver Please download from SMC website. https
Name Function 5 4 1 DA CC-Link communication line A 4 3 2 DB CC-Link communication line B 3 2 3 DG CC-Link ground line 2 1 4 SLD CC-Link shield 1 T-Branched type 5 FG Frame ground (6) Controller setting kit (1) (2) (3) Contents Description Product No. *1 Quantity (1) Controller setting software (CD-ROM) LEC-W2-S 1 (2) Communication cable (3m) LEC-W2-C 1 (3) USB cable (0.3m) LEC-W2-U 1 *1)
CN5: 7.1 T 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 LEC-CMJ-S LEC-CMJ-T MSTB2,5/5-ST-5,08 AU TMSTBP2,5/5-ST-5,08 AU 1 DA CC-Link A 2 DB CC-Link B 3 DG CC-Link 4 SLD CC-Link 5 FG CC-Link CC-Link 1105% 1/2W CC-Link 1305% 1/2W PLC LECP LECP LECP MJ MJ MJ (3) (2) (1) CC-Link * 7.2 2) : AWG2412(0.22.5mm oC *60 LEC-CMJ-S:7mm LEC-CMJ-T:10mm 26 - 7.3 CC-Link CN5 () SZS0.43.5 M2.5 0.50.6Nm CN5
Fig. 1 (2) Be sure to connect a terminating resistor between DA and DB at both ends of the CC-Link system. (Refer to Fig. 2) Fig. 2 (3) The appropriate terminating resistor varies depending on the CC-Link cable used. (Refer to the table and Fig. 3 below.)
Connection to external equipment LED indication Communication wiring diagram Power supply wiring diagram 1:SLD 1:+24V 1:SLD 2:DB Power DC24V 2:F.G. 2:DB 3:DG 3:GND CC-Link OUT CC-Link In 3:DG 4:DA 4:N.C. 4:DA 5:N.C.