MHY MHW Option JIS Symbol Double acting MRHQ Body Option/End Boss Type Type of piping port MHCA2-6 M3 x 0.5 M3 x 0.5 With 4 one-touch fitting With 4 hose nipple M3 x 0.5 Symbol Piping port location Applicable model Misc.

Note 2) When the compressor oil mist discharge concentration is 30mg/m3 (ANR). Accessory part no. Accessory Applicable model AFD20 AFD30 AFD40 AFD40-06 AFD40 Note 1) Bracket assembly AF20P-050AS AD27 AF30P-050AS AD38 AD38NNote 3) AF40P-050AS AD48 AD48NNote 3) AF40P-070AS AD48 AD48NNote 3) N.O. N.C.

Area: (800) 258-9200-www.stevenengineering.com VV3PA5-41-051-03 Base specifications VR 42 41 Individual exhaust Combination symbol Common exhaust Piping 2A Side Side Passage VH Air supply port (P port) is common.

Spacer with Bracket (Z) G Center of F.R.L. body C BB (Y100T, Y200T only) E 1 X-X EE (Y100T, Y200T only) RELEASE X B 2 E X G Seal Y200T Y400T J F A H K Spacer width D Applicable model F 6.8 12 14 18 18 20 G 4.5 5.5 7 9 9 11 H 14 19 21 26 27 31 J 2.8 3.2 4 4 4.6 6.4 K 25 30 41 50 50 70 A 6 3 4 5 5 6 B 82 96 96 120 BB 56 67 C 24.5 29 41 48 48 60 D 40.5 53 68 81.5 86 112 E 20 24 35 40 40 50

Max. 5.75 2-M3 x 0.5 2-M4 x 0.7 depth 8 6-M3 x 0.5 depth 4 Top ported: MSUB1-DE B port A port 2-M3 x 0.5 If the adjustment bolt is removed, rotation will be approximately 270 for the single vane type and 100 for the double vane type.

x 0.5 M5 x 0.8 0.39 0.10 0.59 [0.40] 0.43 [0.33] 0.16 [0.11] 0.36 54 (28) 3 position 0.42 [0.33] 0.16 [0.080] 0.46 0.32 0.11 0.58 [0.32] 22 25 2 position SYJA320-M3 M3 x 0.5 M3 x 0.5 0.9 28 3 position 22 25 2 position SYJA330 M3 x 0.5 Note 1) Value when used on a manifold.

Check the detecting position again and tighten the mounting screw to fix the auto switch definitely (the tightening torque of M3 screw should be about 50 to 70 N/cm). 5. Modification of the detecting position should be made following step #3. Auto Switch Mounting Band Part No.

Check the detecting position again and tighten the mounting screw to fix the auto switch definitely (the tightening torque of M3 screw should be about 50 to 70 N/cm). 5. Modification of the detecting position should be made following step #3. Auto Switch Mounting Band Part No.

Note) Available for the rubber seal type only. 23 Manifold Specification Sheet Series VQC2000: Base-Mounted Type/Plug-in Unit How to order manifolds VV5QC 2 1 08 FD1 B C8 F P T Kit / / 1 2 3 8 VV5QC 2 1 08 SDQ B C8 S Kit Fill out for I/O serial kit only.

06 FH440-08 FH440-10 FH440-12 FH640-03 FH640-04 FH640-06 FH640-08 FH640-10 FH640-12 3/8 3/8 10 10 FH441-04 FH441-06 FH441-08 FH441-10 FH441-12 FH441-16 FH441-20 FH441-24 FH641-04 FH641-06 FH641-08 FH641-10 FH641-12 FH641-16 15 (1/2B) 15 (1/2B) 1/2 1/2 20 20 20 (3/4B) 20 (3/4B) 3/4 3/4 50 50 Max. 21 MPa 25 (1B) 25 (1B) 1 1 80 80 Max. 7 MPa 32 (1 1/4B) 32 (1 1/4B) 1 1/4 1 1/4 120 120 40

Operating range RB Model C 8 8 8 8 D 50 60 50 60 75 85 75 85 85 95 75 85 95 130 100 130 Mounting bolt M3 x 50l M3 x 60l M3 x 50l M3 x 60l M5 x 75l M5 x 85l M5 x 75l M5 x 85l M5 x 85l M5 x 95l M5 x 75l M5 x 85l M6 x 95l M6 x 130l M8 x 100l M8 x 130l MKB12-10 MKB12-20 MKB16-10 MKB16-20 MKB20-10 MKB20-20 MKB25-10 MKB25-20 MKB32-10 MKB32-20 MKB40-10 MKB40-20 MKB50-20 MKB50-50 MKB63-20 MKB63-50

C 8 8 8.5 8.5 D 50 60 50 60 75 85 75 85 85 95 75 85 95 130 100 130 Mounting bolt M3 X 50l M3 X 60l M3 X 50l M3 X 60l M5 X 75l M5 X 85l M5 X 75l M5 X 85l M5 X 85l M5 X 95l M5 X 75l M5 X 85l M6 X 95l M6 X 130l M8 X 100l M8 X 130l MKB12-10 MKB12-20 MKB16-10 MKB16-20 MKB20-10 MKB20-20 MKB25-10 MKB25-20 MKB32-10 MKB32-20 MKB40-10 MKB40-20 MKB50-20 MKB50-50 MKB63-20 MKB63-50 PTo attach and detach

Note Power supply/Output connection cable Description ZS-28-A D Mounting screw (M3 x 8L) (Accessory) Bracket ZS-28-B With M3 x 5L (2 pcs.) Sensor connector ZS-28-C 1 pc. Panel mount adapter Panel mount adapter ZS-27-C With M3 x 8L (2 pcs.) ZS-27-D With M3 x 8L (2 pcs.)

-06-08-01S-3 33 80 83 84 17 20 15.5 12.8 45.4 17 11.1 18.5 76.5 77 78 41 6 KM14-06-08-02S-3 15.2 12.8 KM14-06-08-03S-3 1 4 3 8 1 2 10 6 KM14-06-10-02S-3 44 45 67 7.5 KM14-06-10-03S-3 18.5 12.8 KM14-06-10-04S-3 87.5 88.5 92 81.5 82 84 19 22 21 19 12.8 45.4 17 12.8 21 1 4 3 8 1 2 10 8 KM14-08-10-02S-3 48 88 89 90.5 94 95 98.5 19 71 7.5 KM14-08-10-03S-3 18.5 15.2 KM14-08-10-04S-3 22 22.5 19

The intersection H is the amount of moisture included in the compressed air 1 m3 at 102 psi (0.7 MPa), and a pressure dew point 77F (25C). The amount of moisture is 3.0 g/m3. 10.

bracket Switch mounting nut Hexagon socket head cap bolt (M3 x 0.5 x 14 spring wasdher 2 pcs.)

A A1 E1 L1 MM U1 L M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 16 Y-G02 Y-G03 Y-G04 Y-G05 34 41 42 56 8.5 10.5 14 18 16 20 22 28 25 30 30 40 10.3 12.8 12 16 11.5 14 14 20 34 41 42 56 8.5 16 25 30 30 40 M8 x 1.25 10.3 11.5 21 I-G02 I-G03 I-G04 I-G05 8 10 18 22 8 10 10 14 8 10 18 22 8 10 10 14 IY-G02 IY-G03 IY-G04 IY-G05 +0.058 0 +0.4 +0.2 0.2 0.4 +0.058 0 20 10.5 12.8 14 25.6 20 M10 x 1.25 +0.058

It is calculated using the following formula: 1 x 105 Kv = Q (8) P 1000 Kv : Flow coefficient [m3/h] Q : Flow rate [m3/h] P : Pressure difference [Pa] : Density of fluid [kg/m3] (3) Formula of flow rate It is described by the practical units. Also, the flow rate characteristics are shown in Graph (2).

3 Order 1 piece of finger assembly per one unit. 12-10-10 10 180 Angular Style Air Gripper Cam Style Series MHY2 Dimensions MHY2-10D Pin hole positioning 30 9 9 2-M3 x 0.5 thread depth 4 (Mounting hole) 4 4-M3 x 0.5 MHZ 3H9 + 0.025 0 depth 3 (Thread for mounting attachment) 6 0.005 0.025 MHF 4 4-M3 x 0.5 thread depth 6 (Mounting hole) MHL 3 6 2-3.4 2M3 x 0.5 thread depth 6 12 MHR (Mounting