Mounting: F (Front Flange), Bore Size: 63mm, Thread: Rc, Full Stroke: 200mm, First Stroke: 100mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 3 pcs.

80 600/130 800/180 200 V 800/40 1600/80 1600/80 2400/130 3200/180 * The inrush current of the heater flows for several tens of seconds when using 100 V, while it flows for several seconds when using 200 V.

Heating capacity [W] 600 600 Heating capacity [W] 40 40 32 32 25 25 400 400 5 5 200 200 0 0 0 10 20 30 40 0 10 20 30 40 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-12 Heating capacity (HRR012-A/W-20,HRR018-A/W-20) 9.5.3 HRR024-A/W-20,HRR030-A/W-20 Ambient temp. 800 800 or Ambient temp.

300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.

N.O. 1 2 3 4 5 6 7 8 J 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz 1 2 3 VXD21 VXD22 VXD23 Symbol Nil 2 Valve Symbol Nil 2 Valve N.C. N.O.

Ambient temp. 500 Heating capacity [W] Heating capacity [W] 400 40 40 400 32 32 300 300 25 25 5 5 200 200 100 100 0 0 10 15 20 25 30 35 40 10 15 20 25 30 35 40 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-11 Heating capacity (HRR010-A-20-) 9.5.4 HRR010-W-20400 400 Facility water temp.

m(kg) Load weight: m(kg) 160 600 600 140 500 500 125 400 400 300 300 200 200 100 100 100 500 400 300 200 100 500 400 300 200 Maximum speed: V(mm/s) Maximum speed: V(mm/s) 31

200 25 5 6 13 + 0.2S 10 23 23 30 140 170 210 250 315 385 35 10 10 40 26 + 0.2S 23 30 35 47 335 340 380 450 490 745 655 70 23 25 100 43 + 0.2S 40 53 60 75 605 610 670 735 835 1250 1400 1000 105 40 45 160 55 + 0.2S 65 120 115 170 1100 1100 1100 1200 1400 2350 2650 2900 1750 130 65 80 310 166 + 0.5S 110 140 180 220 1750 1750 1750 1950 2400 3450 4300 4700 2750 200 110 130 560 240 + 0.5S

0.03 0.06 MXS2075 0.020 MXS2030 0.02 0.04 MXS2020 0.015 MXS2050 MXS2040 MXS2010 0.010 MXS2030 MXS2020 MXS2010 0.01 0.02 0.005 100 200 300 0 0 0 100 200 300 160 120 80 40 240 200 Load N 1N = 0.2248 lbf Load N 1N = 0.2248 lbf Load N 1N = 0.2248 lbf 25 25 25 Lr=154mm 0.040 0.07 0.05 MXS25-125 MXS25-150 MXS25-100 0.035 MXS25-150 MXS25-75 MXS25-50 MXS25-40 MXS25-30 MXS25-20 MXS25-10 0.06 MXS25

No. 1 1 Size M4 x 0.7 x 8L BTBT-03, BT-04, BT-05 BT-06, BT-08, BT-12 D-A5, A6 D-F5, J5 D-Z7, Z8 D-Y5, Y6, Y7 BA4-040, BA4-063, BA4-080 BMB4-032, BMB4-050 2 Set screw M4 x 0.7 x 6L 2 BMB5-032 BA7-040, BA7-063, BA7-080 D-A9 D-M9 BBA1 D-A5, A6 D-F5, J5 BT-16, BT-18A, BT-20 BS4-125, BS4-160 BS4-180, BS4-200 BS5-125, BS5-160 BS5-180, BS5-200 D-Z7, Z8 D-Y5, Y6, Y7 When D-F5BA and G5BA auto switches

(The lock-up cylinder can operate at 50 to 200 mm/s.)

)] Flow rate [L/min (ANR)] 06, 07, 08, 09, 10 06, 07, 08, 09, 10 01, 23, 03, 04, 06, 07 01, 23, 03, 04, 06, 07 08, 09, 10, 11 08, 09, 10, 11 03, 04 200 400 06, 07 TMH 02 01, 23 300 50 03, 04 ASD 100 200 01, 23 AS 100 AS-FE 0 0 0 5 0 10 5 0 10 5 0 10 KE Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.

1) Remove the silencer cover. 2) Turn the silencer cover 180 and mount it to the end plate. At the same time, mount the built-in rivet as the same place with the arrow on silencer cover. Arrow External pilot port 14 1/8" female thread (D side only) Note 1) Do not let the gasket get caught when mounting the silencer cover.

Specification 1.1 AC servo motor 1.1.1 How to order L E J S 100 T9 B 500 T X400 Lead [mm] Motor type Stroke [mm] H 50 200 200 T9 AC servo motor to to A 25 1500 1500 B 10 *Refer to the applicable stroke table.

Repetition Pressure characteristics Flow characteristics Supply pressure: 0.2 MPa Set pressure: 0.05 MPa Relief flow characteristics Supply pressure: 0.2 MPa 1.0 0.25 0.15 Output deviation factor (%F.S.) 0.20 0.5 Set pressure (MPa) Set pressure (MPa) 0.10 Set point 0.15 0.0 0.10 0.05 0.5 0.05 1.0 0 200 400 600 0.00 0.0 0.1 0.2 0.3 600 0 200 400 800 Flow rate (L/min (ANR)) Flow rate (L/min

Double acting single rod only 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30 12, 16 5, 10, 15, 20, 25, 30 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches Mounting Bracket Part No.

Basic setting mode Main menu Alarm display menu Maintenance notif Power supply ON Circulating fluid outlet temperature Circulating fluid set temperature 200 ALm mANT 200 XXALM MENU MENU MENU / / / M no (N M circulating fluid return temp AL01 mT01 212 Alarm number (Alarm number minimum RET TEMP / / / M n mT02 AL02 014 Alarm number Circulating fluid outlet pressure PRESS / 79 Circulating fluid

In addition, 3 of the wiring types are available with IP65 enclosures. 50 63 80 100 125 140 160 180 200 250 1100 1000 900 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQ5100--04 VQ5101--04 IP65 compatible Enclosure Individual wiring type kit (Connector) C It is when the cylinder is extending that is meter-out controlled by speed

" SO, "63 a.5 25, 50, 75, 100,125, 150, 175, 200, 250.300, 350. 400. 450, 500 40 " !

M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 12-CY3B15 15 1000 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 12-CY3B25 25 (Both sides) Non-lube 12-CY3B32 32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B50 50 12-CY3B63 63