(MPa) 0.60 0.60 0.50 0.50 0.40 0.40 F.R.L. 0.30 0.30 0.20 0.20 AV 0.10 0.10 0 0 100 200 300 400 500 600 700 800 900 1000 0 0 100 200 300 400 500 600 700 800 900 1000 AU Flow rate (/min (ANR)) Flow rate (/min (ANR)) AF AR ARX21-01 ARX21-02 0.35 0.35 IR 0.30 0.30 Outlet pressure (MPa) Outlet pressure (MPa) VEX 0.25 0.25 0.20 0.20 AMR 0.15 0.15 ITV 0.10 0.10 IC 0.05 0.05 0 0 50 100 150 200 250
specifications see page 8 Media Air Proof pressure 217 PSI (1 .5 MPa) Max. operating pressure 145 PSI (1.0 MPa) Min. operating pressure 12 PSI (0.08 MPa) Operating piston speed 220in/sec '(50500mrn/sec) Standard I 14158' F (-1070' C) Ambient and fluid temperature Switch Capable I 14140' F (-1060' C) Cushion Both ends (Air cushion) Thread tolerance JIS 2 class Allowable stroke tolerance (mm) -250
Bore size CS1, CS2 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm MB, CA2 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Average speed [mm/s] Series 40 50 63 80 100 125 140 160 180 200 250 1100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal VQ4100--03 VQ4101--03 1100 1000 900 800 700 600 500 400 300 200 100 0 VQ5100--04 VQ5101--04 Values at extension
.) * Values for W-R1 Series Integration of the clamping unit and cylinder unit reduces design and assembly labor Cylinder Approx. 70 Clamp assembly 436 mm Selectable proximity switch for checking arm operation (Option) 250 mm Selectable when the mass of the transferred object is either 1000 kg or 3000 kg, with consideration given to the impact during positioning 15-E655 W-R1/W-R3 Series
IFW520 125 VAC 10 to 20 25 1.5 or less 5 5 1.5 0.7 4 4 2.5 1.3 IFW550 250 VAC 20 to 50 60 3 or less 5 5 1 0.5 4 4 1.5 0.8 Note) Hysteresis is the flow rate that is necessary for moving the microswitch from the operation position (ON signal) to the return position (OFF signal). 8 VDC 7 5 3 3 5 4 3 3 5 5 3 3 4 4 3 3 14 VDC 30 VDC 5 5 3 3 4 4 3 3 125 VDC 0.4 0.4 0.1 0.1 0.4 0.4 0.1 0.1 250 VDC
Full stroke Note 1) 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 Bore size (mm) Note First-stage stroke Note 2) 5 mm to "Full stroke" 5 mm RS Q G Note 1) RZQB (through hole type) is only available for full strokes 25, 50 and 75. Note 2) Available in 1 mm increments.
mA -35No.PF-OMO0007CN PF2A710 PF2A750 PF2A711 PF2A721 PF2A751 IP65 050 -2585 () 3585R.H.() 3F.S.(1535 )5F.S.(050 ) AC1000 V1 50 M(DC500 V ) CERoHS (RcNPTG) 1/81/4 3/8 1/2 ADCNBRSUSPBTPtlrFeNiOFC 250 g 290 g 100 g 1 0.927= 20L/min 3 420 (1 atm)65R.H. 0 (1 atm) 4 mm PVC 1.14 mm AWG23 0.72 mm -36No.PF-OMO0007CN () a(L/min) b(L/min) PF2A710 A 1 10 PF2A750 B 5 50 PF2A711 C
setting range 1 to 63 Occupied area(input/output) 200byte / 200byte Communication speed 125k/250k/500kbps Configuration file EDS Device Infomation Vender code: 7 (SMC Corp) Product code: 143 Corresponding message Poll, Strobe, Change of stats, Cyclic DeviceNetTM of power DC1124V Terminating resistor None Communication speed(bps) Maximum length of cable 125k 250k 500k fat cable 500 less 250
STAT CN2(TB/PC) BUS STAT IF ALM MS Devienet NS Devienet LED10.LED ALM LED (7) 12.LEC 9 - 3. 3.1 DC24V10% 200mA() 300mA() (LEC) 8(12) UL, UL1310Class2 TM DeviceNet TM DeviceNet Group2 Only Server MAC ID 163 (/) 200byte / 200byte (186byte / 182byte) 125k/250k/500kbps EDS 7(SMC Corp) 143 Poll, Strobe, Change of stats, Cyclic TM DC1124V DeviceNet (bps) 125k 250k 500k 500 250
Settings1 Content 2 3 OFF OFF 1 Mbps (Default setting) OFF ON 500 kbps ON OFF 250 kbps ON ON 125 kbps : This function is for extension in the future.
Pollution degree For use in Pollution Degree 3 Environment (UL508) Standard CE, UL(CSA), RoHS Weight 170 g 175 g 1: All unused connectors must have a seal cap fitted. 2: The UL agreement temperature is 0 to 50 oC.
0x41(65) SP1 single value teach Determined set point 1 0x42(66) SP2 single value teach Determined set point 2 0x80(128) Device Reset Restart the device 0x82(130) Restore Factory Settings Values are set to the factory settings 0xA8(168) Teach measuring range start Set the start position for measuring range 0xA9(169) Teach measuring range end Set the end position for measuring range 0xAA(170
Hole Thru 1 2 2 1/2 3 3 1/2 4 5 5 1/2 6 7 8 10 1/16 .078 3/32 1/8 5/32 .170 3/16 7/32 1/4 5/16 3/8 1/2 .055 .059 .081 .089 .104 .125 .140 .156 .177 .250 .290 .391 5. Orifice Fittings Many of our small brass fittings such as B1, B2, T1, T2, etc., are available as orifice fittings. In the case of Tees, the branch and/or one end of the run may be an orifice.
186 127 143 -X F MGTM 199 213 228 246 267 291 221 250 80 Individual -X MGTL 180 192 205 220 237 255 154 62 MGTM 271 288 307 328 353 382 321 356 100 MGTL 242 257 274 292 313 335 153 114 453 Series MGT Construction o !
IDUS3E IDUS4E IDUS6E 500 310 55 740 Air flow capacity l/mim(ANR) 295 (300) 475 (430) 703 (640) 60 160 275 225 55 Power consumption W 165 (189) 230 (275) 280 (295) 60 ( ): Previous model IDU3D/4D/6D Series IDFS Series IDFS Inlet air temperature C Model IDFS6E IDFS8E IDFS11E 740 35 1200 1650 Air flow capacity l/mim(ANR) 614 (640) 996 (850) 1370 (1300) 40 35 160 285 230 Power consumption W 170
Compact Guide Cylinder JMGP Series Specications Bore size [mm] 12 (10 x 2) 16 (12 x 2) 20 (16 x 2) 25 (20 x 2) 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) Action Double acting Fluid Air Proof pressure 1.05 MPa Maximum operating pressure 0.7 MPa1 Minimum operating pressure 0.15 MPa Ambient and uid temperature 5 to 60C Piston speed Note) 50 to 300 mm/s1 50 to 250
Double Acting, Single Rod Cylinder Specifications Bore size (mm) 125 140 160 Lube Not required (Non-lube) Fluid Air Proof pressure 1.57 MPa Max. operating pressure 0.97 MPa Min. operating pressure 0.08 MPa CLJ2 50 to 500 mm/s Piston speed Without auto switch: 0 to 70C (No freezing) With auto switch: 0 to 60C (No freezing) Ambient and fluid temperature CLM2 Cushion Air cushion CLG1 Up to 250
to generate a flow rate of 500 l/min (ANR) is P1 0.14 MPa for a 6 orifice (VXK2 4l) and P1 0.3 MPa for a 4.5 orifice (VX2l3l). 3 2 Saturated Steam (663) (179) 1.0 Upstream pressure of valve P1 1.0 MPa (664) (183) Downstream pressure of valve (P2) MPa 0.9 0.95 (662) (174) 0.8 0.9 0.85 (661) (170) 0.7 0.8 0.75 Subsonic (660) (164) 0.6 0.7 Critical pressure 0.65 (658) (158) 0.5 0.6 0.55 Sonic
(g) Stroke (mm) Model 15 10 5 C(D)U6-S,T C(D)U10-S,T C(D)U16-S,T C(D)U20-S,T C(D)U25-S,T C(D)U32-S,T 28 (38) 25 (35) 22 (27) 48 (58) 40 (50) 36 (41) 71 (101) 56 (86) 50 (75) 133 (170) 106 (143) 95 (128) 235 (294) 193 (252) 176 (230) 347 (425) 286 (364) 262 (335) For the mass of auto switch, refer to page 1263.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500 700 900 10 500 700 900 10 700 1,000 Flow rate Q l/min (ANR) How to read