Stations: 06, Systems, Port Combinations: AN [Ejector System, ø5/16" (Common PV)], Exhaust: Complex Exhaust, Wiring: No Wiring, No Valve, Bracket: w/DIN Rail Mounting Bracket, Common Release Pressure Supply: w/o Option, Manifold Individual Supply: Manifold Individual Supply Specification
Stations: 04, Systems, Port Combinations: A [Ejector System, ø8 (Common PV)], Exhaust: Complex Exhaust, Wiring: D-sub Connector, Bracket: w/DIN Rail Mounting Bracket, Common Release Pressure Supply: w/o Option, Manifold Individual Supply: Manifold Individual Supply Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 50, Stroke S(mm): 50, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Clamping Force(kN): 0.98, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P4DWL, Lead Wire Length(m): 3, The number of the switches: 2 pcs.
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 63, Stroke S(mm): 75, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Clamping Force(kN): 1.56, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P4DWSC, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 63, Stroke S(mm): 125, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Clamping Force(kN): 1.56, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P4DWL, Lead Wire Length(m): 3, The number of the switches: 2 pcs
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 50, Stroke S(mm): 100, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Clamping Force(kN): 0.98, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P79WSE, Lead Wire Length(m): 0.3, The number of the switches: 2
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 50, Stroke S(mm): 125, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Clamping Force(kN): 0.98, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P79WSE, Lead Wire Length(m): 0.3, The number of the switches: 2
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 50, Stroke S(mm): 50, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Clamping Force(kN): 0.98, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P79WSE, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 50, Stroke S(mm): 75, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Clamping Force(kN): 0.98, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P79WSE, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 50, Stroke S(mm): 100, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Clamping Force(kN): 0.98, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P79WSE, Lead Wire Length(m): 0.3, The number of the switches: 2
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 63, Stroke S(mm): 150, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Clamping Force(kN): 1.56, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P79WSE, Lead Wire Length(m): 0.3, The number of the switches: 2
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 63, Stroke S(mm): 50, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Clamping Force(kN): 1.56, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P79WSE, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 63, Stroke S(mm): 100, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Clamping Force(kN): 1.56, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P79WSE, Lead Wire Length(m): 0.3, The number of the switches: 2
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 63, Stroke S(mm): 125, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Clamping Force(kN): 1.56, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P79WSE, Lead Wire Length(m): 0.3, The number of the switches: 2
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 63, Stroke S(mm): 150, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Clamping Force(kN): 1.56, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P79WSE, Lead Wire Length(m): 0.3, The number of the switches: 2
SMC's CLK2 series is a perfect choice for holding applications in either a clamped or unclamped state. CLK2 cylinders have a compact lock mechanism which minimizes the extension of the length dimension (2mm shorter), while maintaining the mounting interchangeability with the CLK1 existing product line. The CLK2 is capable of being locked at any position within the entire stroke. A dedicated
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Model: 2 (SGC200), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 10 (0 to 1 MPa), Thread: N (NPT), Port Size: 10 (3/8), Pilot Valve: Y (0.35 W Type, V116), Voltage: 5 (24 VDC), Electrical Entry: W (M12 Connector, 4-pin Type), Surge Suppressor: None, Manual Override: Non-locking Push Type, Bracket Mounting Position: B2 (Bracket on the Right Side), Auto Switch: B