temperature: 113F (45C) RoHS How to Order IDF 30 100 FS Nil C K P R V Nil 1 2 3 Size Size Air compressor size Note) 100 100 kW 125 125 kW 150 150 kW Note) Note that the above values are for reference only.
of sphere R Maximum thread depth P Weight (kg) A B C D T J G H Nominal size Pitch CY Standard: Heavy Load Type Hydraulic: Up to 7 MPa MQQ M JAHF40-16-150 JAHF50-20-150 JAHF63-24-150 JAHF80-30-150 JAHF100-39-150 JAHF100-48-150 40 50 63 80 100 100 16 20 24 30 39 48 1.5 1.5 1.5 1.5 1.5 1.5 75 100 100 125 150 150 76 89 106 131 152 159 50 62 72 82 100 100 18 18 24 38 42 49 50 59.5 66 79 96 96
125, 140 160 12 16 20 25 40 63 80 100 140 160 3-050 4-070 5-080 6-100 8-125 10-150 16-200 20-250 22-250 24-300 Precautions 2.
F = one finger thrust.
Series Variations Series Size Page 25 32 40 63 Slider Type Ball Screw Drive LEFS Series 784 100 W 200 W 400 W Slider Type Belt Drive LEFB Series 805 100 W 200 W 400 W High Rigidity Slider Type Ball Screw Drive LEJS Series 824 100 W 200 W Rod Type LEY Series 848 100 W 200 W 400 W Guide Rod Type LEYG Series 864 100 W 200 W The values in shows the equivalent motor capacity. 780 LE Series Compatible
Nil (2 auto switches) is shipped with a right-hand and a left-hand switch. 90 180 270 90 100 Electrical entry/Lead wire length 90 180 270 90 100 Mounting style Single vane B F Basic style Flange style Double vane F: Except size 40 Grommet/Lead wire 0.5 m Grommet/Lead wire: 3 m Connector/Lead wire 0.5 m Connector/Lead wire: 3 m Connector/Without lead wire Connectors are available only for
kPa 27 to 80 kPa 4.5 to 28 VDC (ZSM1-115) to 100 VDC to 100 VAC 24 to 125 VDC 100 to 250 VAC 24 to 220 VDC 100 to 550 VAC Voltage 100 VAC/DC or less (ZSM1-121) Repeatability 0.05 MPa 0.05 MPa 3% F .S. 3% F.S. 3% F.S. 3% F.S. 10% F.S. 15 kPa or less (ZSM1-115) 0.02 to 0.35 MPa (Without pointer scale) 0.03 to 0.4 MPa (Without pointer scale) Hysteresis (Calibration range of ISG) 0.08 MPa or
100% 10 , 16 20 , 25 540 40% 100% 2150 80% 100% 1120 60% 100% 10L , 16L 510 50% 100% 3150 70% 100% 20L , 25L 520 40% 100% 2130 50% 100% [mm/sec] () 2130 50% 100% 520 40% 100% [mm/sec] () 4150 50% 100% 540 40% 100% 3150 80% 100% 1130 60% 100% 510 40% 100% 22 - 150% LEHZJ 1) (SVON ) 2)CN1 EMG() a)SVRE SETONON SVRE OFF SETON ON b) SVREON SVREON c) SVREON
1 Setting of OUT1 35 F 2 Setting of OUT2 40 F 3 Digital filter setting 43 F 5 FUNC terminal function setting 44 F10 Sub display setting 47 F14 Display with zero cut-off setting 49 F30 Accumulated value hold setting 51 F80 Power saving mode 52 F81 Security code 53 F90 Setting of all functions 55 F96 Sensor input/External input signal status display 57 F97 Copy setting 58 F98 Output check 61
Load weight (kg) Caution The cylinder should be mounted in m1 orientation if maximum dustproofing is required. m m m Moment (Nm) M = F x L F3 M = F x L M = F x L F F2 L2 L1 L3 Maximum load weight Select the load weight from within the range of limits shown in the graphs. Note that the maximum allowable moment value may sometimes exceed even the operating limits shown in the graphs.
200 CM2 32 400 MB 50 300 150 Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 AS3201F -02-08 AS3000-02 200 100 100 50 0 0 200 CM2 40 400 MB 63 150 300 Stroke (mm) Stroke (mm) AS2201F -02-06 AS2200-02 100 AS4000-03 200 50 100 0 0 Solenoid valve Silencer Tubing Speed controller Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 200 300 400 500 600
The guideline is 80% or less. 0 to 100 % 12 Effective load ratio The continuous effective load current is displayed. The effective value is displayed relative to the rated current of 100%. 0 to 300 % 13 Peak load ratio The maximum torque is displayed.
, but must be in the order F, N, L.
Nil N T F Rc NPT NPTF G Combination of manifold options shown below and external pilot specification is not possible.
Series MLGPM Series MLGPL 63 40 to 63: Over 100 stroke 50 to 100 80, 100: Over 200 stroke Type F Type B (Extension locking) (Retraction locking) Section B-B Section B-B Section A-A *Above figure show the unlocked state.
The guideline is 80% or less. 0 to 100 % 12 Effective load ratio The continuous effective load current is displayed. The effective value is displayed relative to the rated current of 100%. 0 to 300 % 13 Peak load ratio The maximum torque is displayed.
L/min [P_2] Set value of OUT2 1000 L/min [H_2] Hysteresis of OUT2 100 L/min : Only available for models with switch outputs for both OUT1 and OUT2. : For input of hysteresis, perform the settings referring to [F 1] Setting of OUT1 (page 35 to) and [F 2] Setting of OUT2 (page 42 to). -27No.PF-OMY0002
120 Pressure 0.6 MPa Gripping force (N) Gripping force (N) 80 100 Pressure 0.6 MPa 0.5 MPa 80 60 0.5 MPa 0.4 MPa 60 0.4 MPa 40 0.3 MPa 0.3 MPa 40 20 20 0.2 MPa 0.2 MPa 0 0 20 40 60 80 100 20 40 60 80 100 Gripping point L (mm) Gripping point L (mm) 526 Series MHK2 Wedge Cam Operation Slide Guide Air Gripper/2-Finger Type Effective Gripping Force: Series MHKL2 Double Acting Indication of