Auto switch model Same surface Same surface D-A9 D-M9 D-M9W 10 Note) 45 45 + 45 (n-2) D-C7 D-C80 10 50 50 + 45 (n-2) D-H7 D-H7W D-H7BAL D-H7NF 10 60 60 + 45 (n-2) D-C73C D-C80C D-H7C 65 + 50 (n-2) 10 65 D-B5 D-B64 D-G5 D-K59 D-B59W 75 + 55 (n-2) 10 75 D-B7 D-B80 D-G79 D-K79 50 + 45 (n-2) 10 45 MGJ Note) For cylinders with 2 auto switches D-A93/M9/M9W.
JIS Symbol 15-9-43 2 Series AS-FG How to Order AS 1 0 3 2 F G 01 06 Body size 1 2 3 4 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Option Type Nil S None With seal 2 3 Elbow Universal M5 and U10/32 are not available with seal. Control type Applicable tubing O.D.
(When replacing the piping adapter ZS-46-N#, tighten it using the same method.) Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm.
Note) Metric size Inch size 23 04 06 08 10 12 Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT Port size AS-FE 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 3.2 4 6 8 10 12 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 KE N AS-FG AS-FG AS-FP Note) For applicable tubing O.D. selection, refer to the Model on page 680. Use 1/8" tube.
Stainless steel specification (SUS303) Port size Thread type M5 x 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 Nil Metric thread (M5) Unified thread (10-32UNF) R(PT) NPT N Needle Valve/Flow Rate Characteristics AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 07,08,09,10,11 05,06,07,08,09,10 05,06 01,03,04 03,04 AS321FG AS331FG AS421FG AS431FG 12,13 10,11 10,11,12 08,09 06,07
Through-hole Both ends tapped Front screw clearance hole Through screw clearance hole B A E N Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. Nominal bore size 056 075 106 150 200 250 9/16" 3/4" 1-1/16" 1-1/2" 2" 2 1/2" Auto switch type Nil Without auto switch (Built-in magnet cylinder) *Refer to the table below for auto switch model numbers.
roller lever Straight plunger Roller plunger Toggle lever SA 00 01 02 05 06 08 30 32 33 34 36 Japan, Asia, Australia, England Europe North America 02 1 4 Black Colour of push button E N VA Green Thread Y Yellow G(PF) Rc(PT) F T N NPTF NPT Push button (Mushroom) Push button (Extended) Push button (Flash) Twist selector (2 position) Key selector (2 position) SA Body option VA Internal pilot
port thread type Type of actuation Nil Rc 2 position single G F Port size 1 N NPT Symbol Applicable series Nil Port size Without sub-plate NPTF T 2 position double 1 8 01 SYA3000 Port size With sub-plate 2 Symbol Nil Port size Without sub-plate Without sub-plate (Pilot port: Expect RC) 1 4 With sub-plate 02 SYA5000 3 position closed center 00 3 1 4 02 With sub-plate 3 8 With sub-plate 3
, 5/16" 8, 1/4" 2 x 3.2 (For mounting) Normal override (Non-locking) 2 x 3.2 (For mounting) Manual override (Non-locking) 1.8 (Ventilation hole) 2 x 2.2 die-cast hole (For manifold gasket positioning) 1/8 (P , EA, EB port) SYA5120-01 1/8 (A, B port) 1736 5 Port Air Operated Valve Series SYA3000/5000/7000 Dimensions/Series SYA5000: Body Ported SYA5220-01 2 position double SYA5220(-F2) C4,
/4 NPT 9 6 3 3/8 NPT 1 10 1/2 NPT 33 12 11 1 NPT 23 13 1 1/2 NPT 24 14 3/4 NPT 29 19 2 NPT 26 16 2 1/2 NPT 27 17 3 NPT 28 18 B Mounting Bracket In an AC appl. give full details 2 Series 20 3 Series 30 4 Series 40 5 Series 50 7 Series 70 8 Series 80 1 2WNO 2 2WNC 3 3WNC 4 3WNO 5 3WDC 6 3WMP 18 Direct Lift 2WNO 27 Direct Lift 2WNC 28 Pilot Lift 2WNC G 1/32 H 3/64 J 1/16 K 3/32 L 7/64 N 1/8
PSI PSI 10 10 5 01 01 02 02 05 05 1 2 5 WATER FLOW-GPM SERIES 58 FLOW CHARTS 97 SOLENOID VALVES . . .
(N specifications) How to Order AS4200-04 AS3200-03 01 S AS 2 2 0 0 AS2200-02 AS2200-01 Option Body size AS1200-M5 None With seal Nil 1 2 3 4 M3, M5 standard S K N 1 8 1 4 , standard standard standard AS1400-M3 Hexagonal lock nut 8 3 Electroless nickel plated 2 1 If more than one option is required, write option part numbers in the order of S, K, N.
OFF n-1 n-2 Error correction Real-time flow rate Window comparator mode H : Hysteresis For PF2D300/301 Note 2) "n" H H LED display Contents Solution ON A current of more than 80 mA is flowing to OUT1. Check the load and the wiring for OUT1. NO OFF n-2 n-1 Real-time flow rate A current of more than 80 mA is flowing to OUT2. Check the load and the wiring for OUT2.
2 position double 3 position closed center 3 position exhaust center 3 position pressure center VFA3122-01-F VFA3130-01 2 1 8 3 VFA3430-01-X1 5 Body ported Base mounted VFA3122-02-F VFA3130-02 2 1 4 3 VFA3430-02-X1 5 1 8 VFA3140-02 2 1 4 (2) 3 VFA3440-02-X1 5 VFA3140-03 2 3 8 3 VFA3440-03-X1 5 Note 1) Port size of the exhaust ports on body ported type are all 1/8.
Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 CHILE SMC Pneumatics (Chile) S.A. Av. La Montaa 1,115 km. 16,5 P.
INSTALLATION 2 1 to 2 6 2.1 Installation direction and clearances . 2 2 2.2 Keep out foreign materials . 2 3 2.3 Cable stress . 2 4 2.4 SSCNET cable laying. 2 4 2.5 Inspection items . 2 6 2.6 Parts having service lives . 2 6 3.
Direct mount type End lock Standard 1 3 3 1 2 Double rod Air Cylinder Direct mount type 10-/1121-/221 3 3 1 2 CA2 Air Cylinder Standard 10113 1 2 CUJ Mini-free Mount Cylinder 10-/1121-/221 3 3 1 2 CDU Free Mount Cylinder 10-/1121-/221 2 3 1 2 CQS Compact Cylinder 10-/1121-/221 2 3 1 2 CQ2 10113 1 2 REC Sine Cylinder Note) 11-/1221-/221 3 1 2 CXSJ 3, 4 Dual Rod Cylinder Note) 10-/11-/1221
Option/Semi-standard symble:When more than one specification is required, indicate in alphanumeric order. 1 3 4 5 6 2 Symble Description 0.020.2MPa 0 0 0 0 Set pressure range 1 1 1 1 0.020.4MPa 2 2 2 2 0.020.8MPa + 1 Exhaust direction 0 0 0 0 Bottom exhaust + 2 Nil Nil Nil Nil Rc Pipe thread type NPT N N N N F F F F G + 3 Port size 01 01 01 01 1/8 + 4 Nil Nil Nil Nil Without pressure gauge
(PLC ) No. (01-051) <> (1)( )1(ABS)2(INC) (2)PLC 15ms(30ms) 13.2 [2](P.53) No. B RESET <>(+) (-) (JOG ) <>(+) (-) (01-052) B RESET -63- () 12 (12 0 ) (2) (3) (4) (5) (6) (7) Alarm _Comment _058 (01-058) 3A B RESET <>No.