2% F.S. (Based on 25C)Oilproof heavy-duty vinyl cable, 3 cores ?3.5, 2 m4 cores Conductor area: 0.15 mm2 (AWG26), Insulator O.D.: 1.0 mmCE Marking, UL/CSA, RoHS compliance
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8), EXH: N01 (Screw-in NPT 1/8)
Nozzle Diameter: 10 (ø1.0mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8), EXH: N01 (Screw-in NPT 1/8), Accessories: N (w/o Bracket, w/o Silencer)
Nozzle Diameter: 05 (ø0.5mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8), EXH: N01 (Screw-in NPT 1/8)
Nozzle Diameter: 10 (ø1.0mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8), EXH: N01 (Screw-in NPT 1/8)
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8), EXH: N01 (Screw-in NPT 1/8), Accessories: N (w/o Bracket, w/o Silencer)
Nozzle Diameter: 05 (ø0.5mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8), EXH: N01 (Screw-in NPT 1/8), Accessories: N (w/o Bracket, w/o Silencer)
Series: 25A-PFM7, Flow Rate Range: 10 [0.2 to 10 (5) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: A (2 NPN Outputs), Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber)
This is a legacy product, and replaced byZH05DSA-N01-N01-N01, VACUUM EJECTOR, 1/8 SUP, VACUUM SERIES, ZH VACUUM EJECTOR, AD, ZH NOZZLE SIZE 0.5, .10582 lb
The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc.
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc.
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc.
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc.
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc.
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc.
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc.
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc.
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc.
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc.