SMC Corporation of America
Elite Part Number Search
Search Results "PF3W720-03-A-MA-X365"

Valve; Stop Valve: None), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes)

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min

Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link

Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)

Valve: None; Stop Valve: None, Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Valve; w/Stop Valve), Return Port Size: 03 (3/8), Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °C)

Valve; Stop Valve: None), Return Port Size: 03 (3/8), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp

Valve; Stop Valve: None), Return Port Size: 03 (3/8), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp

Valve; Stop Valve: None), Return Port Size: 03 (3/8), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp

Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)

Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp

Valve; Stop Valve: None), Return Port Size: 03 (3/8), Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)

Valve; w/Stop Valve), Return Port Size: 03 (3/8), Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes)

Valve; Stop Valve: None), Return Port Size: 03 (3/8), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: A (Out 1: NPN, Out 2: Flow Rate: NPN, Temp.: None,Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: None, Calibration